OSHA SearchOSHA records by employer

Wainland's, Inc.: OSHA inspections and violations

New York, New York · Metal Window and Door Manufacturing · NAICS 332321

3inspections
13citation items
$9,810current penalties
Jan 26, 2016last inspection

Wainland's, Inc. has 3 OSHA inspections on record in New York, the first in 1994.

OSHA's last visit started on Jan 26, 2016, in New York.

Across those inspections OSHA issued 13 citation items: 11 serious and 2 other-than-serious.

OSHA proposed $12,300 in penalties. After settlements and reviews the total is $9,810, down 20%.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Wainland's, Inc. averages $5,040 over 1 cited inspection in that time.

Wainland's, Inc.: OSHA citation items per year, 1994 to 2016
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Wainland's, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341247286 OPENED JAN 26, 2016Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Sep 2, 2016

10 Sullivan Street, New York, NY 10003 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,800$1,680Apr 4, 2016Final
Citation 1, item 2
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$2,800$1,680Apr 4, 2016Final
Citation 1, item 3
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$2,800$1,680Apr 4, 2016Final

Inspection 315433821 OPENED MAR 17, 2011Closed

Unprogrammed related · Complete · Safety · 7 employees at the site · Closed Jun 21, 2012

346 W. 17th Street, New York, NY 10011 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3a
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$2,040Jun 9, 2011Final
Citation 1, item 3b
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0Jun 9, 2011Final

Inspection 109048439 OPENED DEC 8, 1994Closed

Planned · Complete · Safety · 17 employees at the site · Closed May 11, 1995

351 E. 61st., New York, NY 10021 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$450$315Dec 30, 1994Closed
Citation 1, item 2
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$750$525Dec 30, 1994Closed
Citation 1, item 3
29 CFR 1910.215(a)(1) · Grinders and abrasive wheels
Serious$600$420Dec 30, 1994Closed
Citation 1, item 4
29 CFR 1910.253(b)(4)(i) · Gas welding and cutting
Serious$600$420Dec 30, 1994Closed
Citation 1, item 5
29 CFR 1910.303(c) · Electrical equipment, general requirements
Serious$750$525Dec 30, 1994Closed
Citation 1, item 6
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$750$525Dec 30, 1994Closed
Citation 2, item 1
29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$0$0Dec 30, 1994Closed
Citation 2, item 2
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Dec 30, 1994Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1903.2(a)(1)

(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.133(a)(1)

(a) General requirements. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(g)(2)

(2) The employer shall provide the education required in paragraph (g)(1) of this section upon initial employment and at least annually thereafter.

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

Other metal window and door manufacturing employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.