OSHA SearchOSHA records by employer

Walter Smith Brick Company: OSHA inspections and violations

Montgomery, Alabama · Masonry Contractors · NAICS 238140

1inspections
5citation items
$4,500current penalties
Nov 7, 2017last inspection

OSHA has inspected Walter Smith Brick Company once in Alabama.

The inspection began on Nov 7, 2017 on a referral, in Montgomery.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $7,484 and now stand at $4,500, 40% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Walter Smith Brick Company averages $4,500 (1 cited inspection).

Walter Smith Brick Company: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

99employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Walter Smith Brick Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342764545 OPENED NOV 7, 2017Closed

Referral · Partial · Safety · 5 employees at the site · Closed Jan 11, 2019

A New Commercial Development 8739 East Chase Parkway, Montgomery, AL 36117 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,772$1,500Feb 5, 2018Final
Citation 1, item 1b
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$0$0Feb 5, 2018Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,356$1,500Feb 5, 2018Final
Citation 1, item 3a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,356$1,500Feb 5, 2018Final
Citation 1, item 3b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Feb 5, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(c)(2)(ii)

(ii) Unstable objects shall not be used to support scaffolds or platform units.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

Other masonry contractors employers in Alabama

Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.