Inspection 347397390 OPENED APR 8, 2024Closed
21777 Katy Frwy, Katy, TX 77450 · All Other Automotive Repair and Maintenance · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Warehouse Recon LLC 2 times in Texas since 2023.
The latest one began on Apr 8, 2024 to follow up on an earlier case, in Katy.
Those inspections ended with 11 citation items: 10 serious and 1 other-than-serious.
Penalties were first proposed at $37,504 and now stand at $20,627, 45% lower after settlements or reviews.
Spray painting and finishing comes up most often in these citations: 6 items under 1910.107.
How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Warehouse Recon LLC averages $20,627 (1 cited inspection).
Texas · latest 90 days of OSHA records
394employers cited
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Warehouse Recon LLC and get notified the morning OSHA posts a new citation for it.
Watch this company21777 Katy Frwy, Katy, TX 77450 · All Other Automotive Repair and Maintenance · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
21777 Katy Frwy, Katy, TX 77450 · All Other Automotive Repair and Maintenance · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.107(c)(6) · Spray painting and finishing |
Serious | $4,688 | $2,578 | Jul 28, 2023 | Final |
| Citation 1, item 2 29 CFR 1910.107(d)(2) · Spray painting and finishing |
Serious | $4,688 | $2,578 | Jul 28, 2023 | Final |
| Citation 1, item 3 29 CFR 1910.107(f)(4) · Spray painting and finishing |
Serious | $4,688 | $2,578 | Jul 28, 2023 | Final |
| Citation 1, item 4a 29 CFR 1910.107(g)(2) · Spray painting and finishing |
Serious | $4,688 | $2,578 | Jul 28, 2023 | Final |
| Citation 1, item 4b 29 CFR 1910.107(g)(3) · Spray painting and finishing |
Serious | $0 | $0 | Jul 28, 2023 | Final |
| Citation 1, item 5 29 CFR 1910.107(g)(7) · Spray painting and finishing |
Serious | $3,349 | $1,842 | Jul 28, 2023 | Final |
| Citation 1, item 6a 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $4,018 | $2,210 | Jul 28, 2023 | Final |
| Citation 1, item 6b 29 CFR 1910.134(f)(2) · Respiratory protection |
Serious | $0 | $0 | Jul 28, 2023 | Final |
| Citation 1, item 7 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $4,018 | $2,210 | Jul 28, 2023 | Final |
| Citation 1, item 8 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $4,018 | $2,210 | Jul 28, 2023 | Final |
| Citation 2, item 1 29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries |
Other-than-serious | $3,349 | $1,842 | Jul 28, 2023 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1904.39(a)(2)
(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.
29 CFR 1910.107(c)(6)
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
29 CFR 1910.107(d)(2)
(2) General. All spraying areas shall be provided with mechanical ventilation adequate to remove flammable vapors, mists, or powders to a safe location and to confine and control combustible residues so that life is not endangered. Mechanical ventilation shall be kept in operation at all times while spraying operations are being conducted and for a sufficient time thereafter to allow vapors from drying coated articles and drying finishing material residue to be exhausted.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.