OSHA SearchOSHA records by employer

Watkins Services Inc: OSHA inspections and violations

North Myrtle Beach, South Carolina · Residential Remodelers · NAICS 236118

7inspections
17citation items
$6,970current penalties
Feb 9, 2021last inspection

Since 2000, OSHA inspectors have visited Watkins Services Inc in South Carolina 7 times.

The most recent inspection opened on Feb 9, 2021 as a planned inspection, in Greenville.

In all, OSHA issued 17 citation items: 17 serious.

The proposed penalties came to $8,050; today they stand at $6,970, 13% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Watkins Services Inc averages $2,750 across 1 cited inspection.

Watkins Services Inc: OSHA citation items per year, 2000 to 2021
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

43employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Watkins Services Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345147268 OPENED FEB 9, 2021Closed

Planned · Complete · Safety · 10 employees at the site · Closed Mar 22, 2021

436 N. Main St., Greenville, SC 29601 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317889640 OPENED JAN 6, 2015Closed

Referral · Partial · Safety · 5 employees at the site · Closed Mar 20, 2015

137 141 145 Marsh Walk Circle, Mount Pleasant, SC 29464 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,000$2,000Feb 9, 2015Closed
Citation 1, item 2
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$375$375Feb 9, 2015Closed
Citation 1, item 3a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$375$375Feb 9, 2015Closed
Citation 1, item 3b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Feb 9, 2015Closed
Citation 1, item 3c
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Feb 9, 2015Closed

Inspection 315190645 OPENED MAR 23, 2011Closed

Planned · Complete · Safety · 1 employee at the site · Closed Apr 25, 2011

817 South Ocean Blvd, North Myrtle Beach, SC 29582 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311512370 OPENED MAR 4, 2008Closed

Planned · Complete · Safety · 1 employee at the site · Closed Mar 21, 2008

63-65 Ocean Ln, Hilton Head Island, SC 29928 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309794139 OPENED FEB 22, 2006Closed

Planned · Partial · Safety · 9 employees at the site · Closed May 12, 2006

4604 N Ocean Blvd, North Myrtle Beach, SC 29582 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.28(a) · Personal protective equipment
Serious$450$180Mar 9, 2006Closed
Citation 1, item 2
29 CFR 1926.502(b)(2) · Fall protection systems
Serious$750$300Mar 9, 2006Closed
Citation 1, item 3
29 CFR 1926.1052(c)(2) · Stairways in construction
Serious$600$240Mar 9, 2006Closed

Inspection 308239581 OPENED MAY 3, 2005Closed

Planned · Partial · Safety · 9 employees at the site · Closed Aug 2, 2005

4633 Lightkeepers Way, Little River, SC 29566 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$875$875May 17, 2005Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$875$875May 17, 2005Closed
Citation 1, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$875$875May 17, 2005Closed
Citation 1, item 4a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$875$875May 17, 2005Closed
Citation 1, item 4b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0May 17, 2005Closed
Citation 1, item 4c
29 CFR 1926.454(b) · Scaffold training
Serious$0$0May 17, 2005Closed

Inspection 302442223 OPENED OCT 19, 2000Closed

Planned · Partial · Safety · 3 employees at the site · Closed Nov 22, 2000

806 Quail Marsh Oaks, North Myrtle Beach, SC 29785 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$0$0Nov 16, 2000Closed
Citation 1, item 2
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$0$0Nov 16, 2000Closed
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$0$0Nov 16, 2000Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(2)

(2) Winding and spiral stairways shall be equipped with a handrail offset sufficiently to prevent walking on those portions of the stairways where the tread width is less than 6 inches (15 cm).

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

Other residential remodelers employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.