OSHA SearchOSHA records by employer

Weidmann Electrical Technology, Inc.: OSHA inspections and violations

Urbana, Ohio · Other Electronic Component Manufacturing · NAICS 334419

2inspections
5citation items
$12,000current penalties
Feb 5, 2016last inspection

Since 2015, OSHA inspectors have visited Weidmann Electrical Technology, Inc. in Ohio 2 times.

The most recent inspection opened on Feb 5, 2016 after a complaint, in Urbana.

In all, OSHA issued 5 citation items: 2 serious and 3 other-than-serious.

The proposed penalties came to $31,000; today they stand at $12,000, 61% less.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Weidmann Electrical Technology, Inc. averages $6,000 across 2 cited inspections.

Weidmann Electrical Technology, Inc. also files yearly injury logs with OSHA, summarized below.

Weidmann Electrical Technology, Inc.: OSHA citation items per year, 2015 to 2016
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

275employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Weidmann Electrical Technology, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341235216 OPENED FEB 5, 2016Closed

Complaint · Partial · Safety · 145 employees at the site · Closed Mar 5, 2018

700 West Court St., Urbana, OH 43078 · Noncurrent-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$6,000$7,000Jul 21, 2016Final
Citation 1, item 1b
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$7,000$0Jul 21, 2016Final
Citation 1, item 4
29 CFR 1910.305(a)(2)(i) · Electrical wiring methods
Other-than-serious$7,000$3,500Jul 21, 2016Final

Inspection 341135788 OPENED DEC 22, 2015Closed

Complaint · Partial · Health · 550 employees at the site · Closed Jun 28, 2016

700 West Court St., Urbana, OH 43078 · Other Electronic Component Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Other-than-serious$5,500$500May 27, 2016Final
Citation 1, item 2
29 CFR 1910.145(d)(10) · Specifications for accident prevention signs and tags
Other-than-serious$5,500$1,000May 27, 2016Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Urbana site logged 10 recordable injuries or illnesses among about 231 workers: 4.1 per 100 full-time workers, against a median of 1.9 for its industry. Those cases cost 188 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Weidmann Electrical Technology Inc.
Urbana · 2025
231 1044.11.9

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.145 · Specifications for accident prevention signs and tags

29 CFR 1910.145(d)(10)

(10) Slow-moving vehicle emblem. This emblem (see fig. J-7) consists of a fluorescent yellow-orange triangle with a dark red reflective border. The yellow-orange fluorescent triangle is a highly visible color for daylight exposure. The reflective border defines the shape of the fluorescent color in daylight and creates a hollow red triangle in the path of motor vehicle headlights at night. The emblem is intended as a unique identification for, and it shall be used only on, vehicles which by design move slowly (25 m.p.h. or less) on the public roads. The emblem is not a clearance marker for wide machinery nor is it intended to replace required lighting or marking of slow-moving vehicles. Neither the color film pattern and its dimensions nor the backing shall be altered to permit use of advertising or other markings. The material, location, mounting, etc., of the emblem shall be in accorda

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.305 · Electrical wiring methods