OSHA SearchOSHA records by employer

Weldon Manufacturing: OSHA inspections and violations

Fort Worth, Texas · Motor Vehicle Body Manufacturing · NAICS 336211

4inspections
17citation items
$5,025current penalties
Nov 5, 2015last inspection

OSHA has inspected Weldon Manufacturing 4 times in Texas since 1987.

The latest one began on Nov 5, 2015 after a complaint, in Fort Worth.

Those inspections ended with 17 citation items: 12 serious and 5 other-than-serious.

Penalties were first proposed at $9,020 and now stand at $5,025, 44% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 4 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Weldon Manufacturing averages $3,960 (1 cited inspection).

Weldon Manufacturing: OSHA citation items per year, 1987 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Weldon Manufacturing and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341037836 OPENED NOV 5, 2015Closed

Complaint · Partial · Health · 15 employees at the site · Closed Aug 13, 2018

3488 Bethlehem Av, Fort Worth, TX 76111 · Motor Vehicle Body Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,000$1,100Mar 11, 2016Final
Citation 1, item 2
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$2,400$1,320Mar 11, 2016Final
Citation 1, item 3
29 CFR 1910.134(d)(3)(i) · Respiratory protection
Serious$2,400$1,320Mar 11, 2016Final
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$400$220Mar 11, 2016Final

Inspection 106602352 OPENED MAR 28, 1990Closed

Planned · Complete · Safety · 26 employees at the site · Closed Jun 1, 1990

3499 Bethlehem, Fort Worth, TX 76111 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(d)(1) · General requirements
Serious$280$170May 3, 1990Closed
Citation 1, item 2
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$210$125May 3, 1990Closed
Citation 1, item 3
29 CFR 1910.252(a)(2)(ivc) · Welding fire safety
Serious$280$140May 3, 1990Closed
Citation 1, item 4
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$210$125May 3, 1990Closed
Citation 1, item 5
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$350$210May 3, 1990Closed
Citation 1, item 6a
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$210$125May 3, 1990Closed
Citation 1, item 6b
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$0$0May 3, 1990Closed
Citation 1, item 7
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$140$85May 3, 1990Closed
Citation 1, item 8
29 CFR 1910.1200(h) · Hazard communication
Serious$140$85May 3, 1990Closed
Citation 2, item 1
29 CFR 1904.5(c) · Determination of work-relatedness
Other-than-serious$0$0May 3, 1990Closed
Citation 2, item 2
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0May 3, 1990Closed
Citation 2, item 3
29 CFR 1910.212(a)(5) · Machine guarding
Other-than-serious$0$0May 3, 1990Closed
Citation 2, item 4
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0May 3, 1990Closed

Inspection 101597318 OPENED SEP 9, 1987Closed

Follow-up · Partial · Safety · 25 employees at the site · Closed Sep 14, 1987

3499 Bethlehem, Fort Worth, TX 76111 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 100701242 OPENED JUN 8, 1987Closed

Monitoring · Partial · Safety · 25 employees at the site · Closed Jan 4, 1988

3499 Bethlehem, Fort Worth, TX 76111 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.5 · Determination of work-relatedness

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(h)

(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(2)

(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.22 · General requirements

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise

Other motor vehicle body manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.