OSHA SearchOSHA records by employer

Wellman Advanced Materials LLC: OSHA inspections and violations

Poston, South Carolina · Artificial and Synthetic Fibers and Filaments Manufacturing · NAICS 325222

1inspections
2citation items
$3,075current penalties
Dec 4, 2017last inspection

OSHA has inspected Wellman Advanced Materials LLC once in South Carolina.

The inspection began on Dec 4, 2017 as a planned inspection, in Poston.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $3,075 and still stand at $3,075.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Wellman Advanced Materials LLC averages $3,075 (1 cited inspection).

Wellman Advanced Materials LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

41employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Wellman Advanced Materials LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342825387 OPENED DEC 4, 2017Closed

Planned · Complete · Health · 400 employees at the site · Closed Apr 9, 2018

520 Kingsburg Hwy, Poston, SC 29555 · Artificial and Synthetic Fibers and Filaments Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$1,200$1,200Mar 6, 2018Final
Citation 1, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$1,875$1,875Mar 6, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

Other artificial and synthetic fibers and filaments manufacturing employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.