Inspection 347979676 OPENED JAN 14, 2025Closed
5801 Bluff Road, Hopkins, SC 29061 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Hopkins, South Carolina · All Other Miscellaneous Chemical Product and Preparation Manufacturing · NAICS 325998
Westinghouse Electric Co LLC has 9 OSHA inspections on record in South Carolina, the first in 1983.
OSHA's last visit started on Jan 14, 2025 after a complaint, in Hopkins.
Across those inspections OSHA issued 7 citation items: 3 serious and 4 other-than-serious.
OSHA proposed $2,590 in penalties. After settlements and reviews the total is $1,085, down 58%.
Most often, OSHA cited 1910.95, noise (3 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Westinghouse Electric Co LLC averages $875 over 1 cited inspection in that time.
South Carolina · latest 90 days of OSHA records
41employers cited
Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in South Carolina
Checking a subcontractor, a client or your own company? Watch Westinghouse Electric Co LLC and get notified the morning OSHA posts a new citation for it.
Watch this companyOSHA records show Westinghouse Electric Co LLC at 9 sites in 3 states. Together they've had 20 inspections and $29,747 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 9 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
See plans5801 Bluff Road, Hopkins, SC 29061 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5801 Bluff Road, Hopkins, SC 29061 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5801 Bluff Rd, Hopkins, SC 29061 · Oil and Gas Extraction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1.12(A) |
Serious | $1,750 | $875 | Mar 22, 2016 | Final |
5801 Bluff Rd, Hopkins, SC 29061 · Other Basic Inorganic Chemical Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5801 Bluff Rd., Columbia, SC 29250 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.95(b)(1) · Noise |
Serious | $420 | $210 | Jan 16, 1991 | Final |
| Citation 1, item 2 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $420 | $0 | Jan 16, 1991 | Final |
| Citation 2, item 1 29 CFR 1910.95(d)(1) · Noise |
Other-than-serious | $0 | $0 | Jan 16, 1991 | Final |
| Citation 2, item 2 29 CFR 1910.95(k)(1) · Noise |
Other-than-serious | $0 | $0 | Jan 16, 1991 | Final |
| Citation 2, item 3 29 CFR 1910.1200(f)(5) · Hazard communication |
Other-than-serious | $0 | $0 | Jan 16, 1991 | Final |
I-26 & Us 1, W. Columbia, SC 29169 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2210 Laurens Hwy, Greenwood, SC 29648 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Bluff Rd, Columbia, SC 29250 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 30002 |
Other-than-serious | $0 | $0 | Dec 1, 1983 | Closed |
Us 52, St Stephens, SC 29479 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(f)(5)
(f) Any organic peroxide which, in laboratory testing, neither detonates in the cavitated state nor deflagrates at all and shows only a low or no effect when heated under confinement as well as low or no explosive power shall be defined as organic peroxide TYPE F;
29 CFR 1910.151(c)
(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.
29 CFR 1910.95(b)(1)
(b)(1) When employees are subjected to sound exceeding those listed in Table G-16, feasible administrative or engineering controls shall be utilized. If such controls fail to reduce sound levels within the levels of Table G-16, personal protective equipment shall be provided and used to reduce sound levels within the levels of the table.
Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.