OSHA SearchOSHA records by employer

Westran Thermal Processing, LLC dba Precision Quincy Ovens, LLC / Infratrol, LLC: OSHA inspections and violations

South Beloit, Illinois · Industrial Process Furnace and Oven Manufacturing · NAICS 333994

1inspections
15citation items
$82,500current penalties
May 16, 2024last inspection

Westran Thermal Processing, LLC dba Precision Quincy Ovens, LLC / Infratrol, LLC has one OSHA inspection on record in Illinois.

OSHA opened it on May 16, 2024 after a complaint, in South Beloit.

From that inspection OSHA issued 15 citation items: 5 serious and 10 other-than-serious.

OSHA proposed $201,006 in penalties. After settlements and reviews the total is $82,500, down 59%.

Most often, OSHA cited 1910.107, spray painting and finishing (6 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Westran Thermal Processing, LLC dba Precision Quincy Ovens, LLC / Infratrol, LLC averages $82,500 over 1 cited inspection in that time.

Westran Thermal Processing, LLC dba Precision Quincy Ovens, LLC / Infratrol, LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

417employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Westran Thermal Processing, LLC dba Precision Quincy Ovens, LLC / Infratrol, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347490708 OPENED MAY 16, 2024Closed

Complaint · Partial · Health · 49 employees at the site · Closed Apr 2, 2026

483 Gardner Street, South Beloit, IL 61080 · Industrial Process Furnace and Oven Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Other-than-serious$8,067$3,700Oct 25, 2024Final
Citation 1, item 2
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$8,067$8,067Oct 25, 2024Final
Citation 1, item 4a
29 CFR 1910.107(b)(10) · Spray painting and finishing
Serious$8,067$8,067Oct 25, 2024Final
Citation 1, item 4b
29 CFR 1910.107(c)(6) · Spray painting and finishing
Other-than-serious$0$0Oct 25, 2024Final
Citation 1, item 4c
29 CFR 1910.107(c)(8) · Spray painting and finishing
Other-than-serious$0$0Oct 25, 2024Final
Citation 1, item 5a
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$8,067$3,813Oct 25, 2024Final
Citation 1, item 5b
29 CFR 1910.107(g)(3) · Spray painting and finishing
Other-than-serious$8,067$0Oct 25, 2024Final
Citation 1, item 6a
29 CFR 1910.133(a)(1) · Eye and face protection
Other-than-serious$6,453$3,700Oct 25, 2024Final
Citation 1, item 6b
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0Oct 25, 2024Final
Citation 1, item 7a
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$4,839$3,700Oct 25, 2024Final
Citation 1, item 7b
29 CFR 1910.134(k)(6) · Respiratory protection
Other-than-serious$0$0Oct 25, 2024Final
Citation 1, item 8a
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$6,453$6,453Oct 25, 2024Final
Citation 2, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$112,926$15,000Oct 25, 2024Final
Citation 2, item 2
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$15,000$15,000Jan 17, 2025Final
Citation 2, item 3
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Other-than-serious$15,000$15,000Jan 17, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.28 · Fall protection in general industry

Other industrial process furnace and oven manufacturing employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.