OSHA SearchOSHA records by employer

Willow Tex, LLC.: OSHA inspections and violations

Mount Airy, North Carolina · Fabric Coating Mills · NAICS 313320

3inspections
10citation items
$3,337current penalties
Aug 20, 2019last inspection

Willow Tex, LLC. has 3 OSHA inspections on record in North Carolina, the first in 2015.

OSHA's last visit started on Aug 20, 2019 to follow up on an earlier case, in Mount Airy.

Across those inspections OSHA issued 10 citation items: 2 serious and 8 other-than-serious.

OSHA proposed $4,525 in penalties. After settlements and reviews the total is $3,337, down 26%.

Most often, OSHA cited 1910.305, electrical wiring methods (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,872. Willow Tex, LLC. averages $3,337 over 1 cited inspection in that time.

Willow Tex, LLC. also files yearly injury logs with OSHA, summarized below.

Willow Tex, LLC.: OSHA citation items per year, 2015 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Willow Tex, LLC. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344246228 OPENED AUG 20, 2019Closed

Follow-up · Partial · Safety · 36 employees at the site · Closed Aug 22, 2019

501 Piedmont Triad West Drive, Mount Airy, NC 27030 · Fabric Coating Mills · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343914511 OPENED APR 5, 2019Closed

Planned · Complete · Safety · 36 employees at the site · Closed May 21, 2019

501 Piedmont Triad West Drive, Mount Airy, NC 27030 · Fabric Coating Mills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$750$700Apr 17, 2019Final
Citation 1, item 2
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$750$700Apr 17, 2019Final
Citation 1, item 3
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$2,800$1,837Apr 17, 2019Final
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$225$100Apr 17, 2019Final
Citation 2, item 2
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Apr 17, 2019Final
Citation 2, item 3
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Apr 17, 2019Final
Citation 2, item 4a
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Apr 17, 2019Final
Citation 2, item 4b
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Apr 17, 2019Final
Citation 2, item 5
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Apr 17, 2019Final
Citation 2, item 6
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Apr 17, 2019Final

Inspection 340991736 OPENED OCT 16, 2015Closed

Complaint · Partial · Health · 23 employees at the site · Closed Nov 25, 2015

501 Piedmont Triad West Drive, Mount Airy, NC 27030 · Leather and Hide Tanning and Finishing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Mount Airy site logged 0 recordable injuries or illnesses among about 20 workers: 0.0 per 100 full-time workers, against a median of 2.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Willow Tex, LLC
Mount Airy · 2023
20 000.02.6
Willow Tex HQ
Mount Airy · 2019
38 000.02.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(c)(1)

(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.212(b)

(b) Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other fabric coating mills employers in North Carolina

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.