OSHA SearchOSHA records by employer

Window Solutions, Inc.: OSHA inspections and violations

Waukesha, Wisconsin · Finish Carpentry Contractors · NAICS 238350

4inspections
16citation items
$23,320current penalties
Jul 12, 2023last inspection

Window Solutions, Inc. has 4 OSHA inspections on record in Wisconsin, the first in 2012.

OSHA's last visit started on Jul 12, 2023 on a referral, in Waukesha.

Across those inspections OSHA issued 16 citation items: 6 serious and 10 other-than-serious.

OSHA proposed $36,774 in penalties. After settlements and reviews the total is $23,320, down 37%.

Most often, OSHA cited 1926.1053, ladders in construction (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Window Solutions, Inc. averages $7,373 over 3 cited inspections in that time.

Window Solutions, Inc. also files yearly injury logs with OSHA, summarized below.

Window Solutions, Inc.: OSHA citation items per year, 2012 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Window Solutions, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346823933 OPENED JUL 12, 2023Closed

Referral · Partial · Safety · 150 employees at the site · Closed Dec 5, 2023

1741 Dolphin Drive, Waukesha, WI 53186 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$9,488$5,700Aug 1, 2023Final
Citation 2, item 1
29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries
Other-than-serious$5,000$2,500Aug 1, 2023Final

Inspection 345716278 OPENED JAN 10, 2022Closed

Referral · Partial · Safety · 5 employees at the site · Closed Mar 30, 2022

8710 North Fielding Road, Bayside, WI 53217 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jan 6, 2022: Employee falls from ladder, fractures leg and thumb

At 9:15 a.m. on January 6, 2022, an employee removed a window while working from a ladder. While working, the ladder slipped out and the employee fell approximately eight feet. The employee was taken to the hospital and admitted to treat fractures to the leg and thumb.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1053(b)(5)(i) · Ladders in construction
Serious$9,510$6,657Mar 9, 2022Final
Citation 1, item 1b
29 CFR 1926.1053(b)(7) · Ladders in construction
Serious$0$0Mar 9, 2022Final

Inspection 341967883 OPENED DEC 13, 2016Closed

Referral · Partial · Health · 25 employees at the site · Closed Mar 28, 2017

12322 North Fairway Heights Drive, Mequon, WI 53092 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$4,988$3,492Jan 6, 2017Final
Citation 1, item 2
29 CFR 1926.1053(b)(7) · Ladders in construction
Serious$4,988$3,492Jan 6, 2017Final
Citation 2, item 1
29 CFR 1904.4(a) · Recording criteria
Other-than-serious$400$280Jan 6, 2017Final

Inspection 337115398 OPENED OCT 29, 2012Closed

Complaint · Partial · Health · 23 employees at the site · Closed Apr 1, 2013

1510 Paramount Drive, Waukesha, WI 53186 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.26(c)(2)(vii) · Portable metal ladders
Serious$1,600$800Feb 20, 2013Final
Citation 2, item 1
29 CFR 1910.107(c)(6) · Spray painting and finishing
Other-than-serious$0$0Feb 20, 2013Final
Citation 2, item 2
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$0$0Feb 20, 2013Final
Citation 2, item 3
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Feb 20, 2013Final
Citation 2, item 4
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$400$200Feb 20, 2013Final
Citation 2, item 8
29 CFR 1910.134(k)(3) · Respiratory protection
Other-than-serious$400$200Feb 20, 2013Final
Citation 2, item 9
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Feb 20, 2013Final
Citation 2, item 10
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Feb 20, 2013Final
Citation 2, item 11
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Feb 20, 2013Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Waukesha site logged 5 recordable injuries or illnesses among about 163 workers: 4.2 per 100 full-time workers, against a median of 2.3 for its industry. Those cases cost 20 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Milwaukee
Waukesha · 2025
163 504.22.3
Renewal by Andersen South
Waukesha · 2024
242 504.22.3

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(2)

(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.

29 CFR 1904.4 · Recording criteria

29 CFR 1904.4(a)

(a) Basic requirement. Each employer required by this part to keep records of fatalities, injuries, and illnesses must record each fatality, injury and illness that:

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.26 · Portable metal ladders

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.501 · Fall protection in construction

Other finish carpentry contractors employers in Wisconsin