Inspection 346770662 OPENED JUN 8, 2023Closed
1157 55th Street, Brooklyn, NY 11219 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2018, OSHA inspectors have visited WJP Builders Corp. in New York 8 times.
The most recent inspection opened on Jun 8, 2023 to follow up on an earlier case, in Brooklyn.
In all, OSHA issued 26 citation items: 24 serious and 2 repeat.
The proposed penalties came to $129,726; today they stand at $104,090, 20% less.
The rule cited most here is 1926.451 (scaffolds, general requirements), 6 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. WJP Builders Corp. averages $17,348 across 6 cited inspections.
New York · latest 90 days of OSHA records
356employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch WJP Builders Corp. and get notified the morning OSHA posts a new citation for it.
Watch this company1157 55th Street, Brooklyn, NY 11219 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1157 55th Street, Brooklyn, NY 11219 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.20(b)(2) · Construction safety programs |
Serious | $5,801 | $5,801 | Dec 9, 2022 | Final |
| Citation 1, item 2 29 CFR 1926.21(b)(2) · Construction safety training |
Serious | $5,801 | $5,801 | Dec 9, 2022 | Final |
| Citation 1, item 3 29 CFR 1926.451(c)(3) · Scaffolds, general requirements |
Serious | $5,801 | $5,801 | Dec 9, 2022 | Final |
| Citation 1, item 4 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $5,801 | $5,801 | Dec 9, 2022 | Final |
| Citation 1, item 5 29 CFR 1926.454(a) · Scaffold training |
Serious | $5,801 | $5,801 | Dec 9, 2022 | Final |
| Citation 1, item 6 29 CFR 1926.501(a)(2) · Fall protection in construction |
Serious | $5,801 | $5,801 | Dec 9, 2022 | Final |
| Citation 1, item 7 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $5,801 | $5,801 | Dec 9, 2022 | Final |
| Citation 1, item 8 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Serious | $5,801 | $5,801 | Dec 9, 2022 | Final |
| Citation 1, item 9 29 CFR 1926.850(a) · Preparatory operations |
Serious | $5,801 | $5,801 | Dec 9, 2022 | Final |
| Citation 2, item 1 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Repeat | $11,602 | $11,602 | Dec 9, 2022 | Final |
1101 55th St., Brooklyn, NY 11219 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.20(b)(2) · Construction safety programs |
Serious | $4,241 | $2,120 | Jun 3, 2020 | Final |
| Citation 1, item 2 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Serious | $4,241 | $2,123 | Jun 3, 2020 | Final |
| Citation 1, item 3 29 CFR 1926.451(c)(2) · Scaffolds, general requirements |
Serious | $5,937 | $3,819 | Jun 3, 2020 | Final |
| Citation 1, item 4 29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements |
Serious | $5,937 | $3,819 | Jun 3, 2020 | Final |
| Citation 1, item 5 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $5,937 | $3,819 | Jun 3, 2020 | Final |
1232 39th Street, Brooklyn, NY 11218 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.304(h)(1) · Woodworking tools |
Serious | $5,834 | $3,750 | Nov 18, 2019 | Final |
| Citation 1, item 2 29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites |
Serious | $5,834 | $3,750 | Nov 18, 2019 | Final |
1342 40th St, Brooklyn, NY 11218 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.150(a)(4) · Fire protection |
Serious | $2,500 | $1,680 | Oct 30, 2019 | Final |
| Citation 1, item 2 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Serious | $3,126 | $2,100 | Oct 30, 2019 | Final |
| Citation 2, item 1 29 CFR 1926.1052(c)(1)(i) · Stairways in construction |
Repeat | $6,252 | $4,220 | Oct 30, 2019 | Final |
1150 58th St, Brooklyn, NY 11219 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1214 40th St., Brooklyn, NY 11218 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.405(a)(2)(ii)(a) · Job-site wiring |
Serious | $3,880 | $3,880 | Dec 21, 2018 | Final |
| Citation 1, item 1b 29 CFR 1926.405(a)(2)(ii)(e) · Job-site wiring |
Serious | $2,772 | $0 | Dec 21, 2018 | Final |
| Citation 1, item 3 29 CFR 1926.405(b)(2) · Job-site wiring |
Serious | $3,880 | $2,000 | Dec 21, 2018 | Final |
| Citation 1, item 4 29 CFR 1926.405(g)(2)(iii) · Job-site wiring |
Serious | $2,772 | $1,120 | Dec 21, 2018 | Final |
5414 12th Avenue, Brooklyn, NY 11219 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.1052(c)(1)(i) · Stairways in construction |
Serious | $2,772 | $2,079 | Jun 28, 2018 | Final |
| Citation 1, item 1b 29 CFR 1926.1052(c)(1)(ii) · Stairways in construction |
Serious | $0 | $0 | Jun 28, 2018 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1052(c)(1)(i)
(i) At least one handrail; and
29 CFR 1926.1052(c)(1)(ii)
(ii) One stairrail system along each unprotected side or edge.
29 CFR 1926.150(a)(4)
(4) All firefighting equipment shall be periodically inspected and maintained in operating condition. Defective equipment shall be immediately replaced.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.