Inspection 341758860 OPENED SEP 8, 2016Closed
600 Greenlawn Drive, Columbia, SC 29209 · Siding Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Columbia, South Carolina · Siding Contractors · NAICS 238170
Since 2016, OSHA inspectors have visited Wood Connection Inc in South Carolina 2 times.
The most recent inspection opened on Sep 8, 2016 to follow up on an earlier case, in Columbia.
In all, OSHA issued 2 citation items: 2 serious.
The penalties, $2,000 in total, stand where OSHA first set them.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Wood Connection Inc averages $2,000 across 1 cited inspection.
1 inspection on this page followed a fatal incident.
South Carolina · latest 90 days of OSHA records
41employers cited
Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in South Carolina
Checking a subcontractor, a client or your own company? Watch Wood Connection Inc and get notified the morning OSHA posts a new citation for it.
Watch this company600 Greenlawn Drive, Columbia, SC 29209 · Siding Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
600 Greenlawn Drive, Columbia, SC 29209 · Siding Contractors · OSHA's record · Phone and website on Google Maps
Incident on Mar 8, 2016 (fatal): One employee electrocuted, one burned when scaffold pole mak
At approximately 1:35 p.m. on March 8, 2016, Employees #1 and #2 were on the ground level of the north side of a three story apartment building number 1. Both employees were getting ready to set a 41-ft 8-in. long aluminum scaffold pole up right for a scaffold set up. A coworker was on the roof area of building number 1 with a rope to pull the scaffold pole up right. The pole was mostly upright, when a strong breeze blew the scaffold pole towards a 13,800 volt single phase power line. Employee #1 and Employee #2 were holding scaffold pole when it made contact with the power line. Employee #1 died on site. Employee #2 received third degree burns and was transported to a burn center. Primary phase of power line above the ground level was 38-ft high. The distance from scaffold pole, when it was upright, to primary phase was 28-ft. The amperage of power line with no load was 0. The fault amperage current when scaffold pole made contact with power line was 2,558 amps. The neutral line was 31-ft 5-in. above ground level.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 3a 29 CFR 1926.451(f)(6) · Scaffolds, general requirements |
Serious | $2,000 | $2,000 | Jul 7, 2016 | Final |
| Citation 1, item 3b 29 CFR 1926.454(a) · Scaffold training |
Serious | $0 | $0 | Jul 7, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(f)(6)
(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:
29 CFR 1926.454(a)
(a) The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable:
Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.