Inspection 348838871 OPENED MAR 25, 2026Closed
1905 Cong W L Dickinson Dr., Montgomery, AL 36109 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Montgomery, Alabama · Drywall and Insulation Contractors · NAICS 238310
OSHA has inspected Woolard Brothers Commercial Contracting, Inc. 7 times in Alabama since 1998.
The latest one began on Mar 25, 2026 as a planned inspection, in Montgomery.
Those inspections ended with 16 citation items: 13 serious, 1 repeat and 2 other-than-serious.
Penalties were first proposed at $26,103 and now stand at $17,008, 35% lower after settlements or reviews.
Scaffolds, general requirements comes up most often in these citations: 9 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Woolard Brothers Commercial Contracting, Inc. averages $3,775 (2 cited inspections).
Alabama · latest 90 days of OSHA records
94employers cited
Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Alabama
Checking a subcontractor, a client or your own company? Watch Woolard Brothers Commercial Contracting, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company1905 Cong W L Dickinson Dr., Montgomery, AL 36109 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Shopping Plaza 1032 Boll Weevil Cir, Enterprise, AL 36330 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.453(b)(2)(v) · Aerial lifts |
Serious | $5,636 | $3,650 | Jul 3, 2019 | Final |
207 Montgomery Street, Montgomery, AL 36107 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.501(b)(4)(i) · Fall protection in construction |
Serious | $6,467 | $3,900 | Sep 19, 2018 | Final |
| Citation 1, item 1b 29 CFR 1926.502(i)(3) · Fall protection systems |
Serious | $0 | $0 | Sep 19, 2018 | Final |
| Citation 1, item 1c 29 CFR 1926.502(i)(4) · Fall protection systems |
Serious | $0 | $0 | Sep 19, 2018 | Final |
1144 N. University, Montgomery, AL 36109 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.300(a) · Tools—Hand and Power: general requirements |
Serious | $3,000 | $2,000 | Apr 27, 2010 | Closed |
495 Molton Street, Montgomery, AL 36104 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements |
Serious | $1,200 | $1,080 | Jun 12, 2009 | Closed |
| Citation 1, item 2a 29 CFR 1926.451(b)(10) · Scaffolds, general requirements |
Other-than-serious | $1,200 | $0 | Jun 12, 2009 | Closed |
| Citation 1, item 2b 29 CFR 1926.452(c)(3) · Rules for each type of scaffold |
Other-than-serious | $0 | $0 | Jun 12, 2009 | Closed |
| Citation 1, item 4 29 CFR 1926.502(d)(8) · Fall protection systems |
Serious | $2,100 | $1,890 | Jun 12, 2009 | Closed |
| Citation 2, item 1 29 CFR 1926.451(b)(1)(ii) · Scaffolds, general requirements |
Repeat | $4,200 | $2,700 | Jun 12, 2009 | Closed |
135 Court St, Prattville, AL 36066 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Serious | $1,250 | $1,000 | Jan 29, 2009 | Closed |
| Citation 1, item 1b 29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements |
Serious | $0 | $0 | Jan 29, 2009 | Closed |
1144 N. University, Montgomery, AL 36109 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Serious | $525 | $394 | Sep 23, 1998 | Closed |
| Citation 1, item 1b 29 CFR 1926.451(c)(2) · Scaffolds, general requirements |
Serious | $0 | $0 | Sep 23, 1998 | Closed |
| Citation 1, item 1c 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $0 | $0 | Sep 23, 1998 | Closed |
| Citation 1, item 2 29 CFR 1926.451(f)(3) · Scaffolds, general requirements |
Serious | $525 | $394 | Sep 23, 1998 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.300(a)
(a) Condition of tools. All hand and power tools and similar equipment, whether furnished by the employer or the employee, shall be maintained in a safe condition.
29 CFR 1926.451(b)(1)
(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:
29 CFR 1926.451(b)(1)(ii)
(ii) Where the employer makes the demonstration provided for in paragraph (b)(1)(i) of this section, the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 9 1/2 inches (24.1 cm).
Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.