XJTT Hospitality Inc.: OSHA inspections and violations

Cabo Rojo, Puerto Rico · Commercial and Institutional Building Construction · NAICS 236220

1inspections
2citation items
$375current penalties
Feb 10, 2015last inspection

XJTT Hospitality Inc. has one OSHA inspection on record in Puerto Rico.

OSHA opened it on Feb 10, 2015 as a planned inspection, in Cabo Rojo.

From that inspection OSHA issued 2 citation items: 1 serious and 1 other-than-serious.

OSHA proposed $750 in penalties. After settlements and reviews the total is $375, down 50%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. XJTT Hospitality Inc. averages $375 over 1 cited inspection in that time.

XJTT Hospitality Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Puerto Rico · latest 90 days of OSHA records

108employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Puerto Rico

Checking a subcontractor, a client or your own company? Watch XJTT Hospitality Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340345644 OPENED FEB 10, 2015Closed

Planned · Complete · Safety · 8 employees at the site · Closed Apr 15, 2015

Carr. 3301 Km 2.7, Sector El Combate, Cabo Rojo, PR 00623 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$750$375Mar 17, 2015Final
Citation 2, item 1
29 CFR 1926.405(a)(2)(ii)(b) · Job-site wiring
Other-than-serious$0$0Mar 17, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(b)

(B) Branch circuits shall originate in a power outlet or panelboard. Conductors shall be run as multiconductor cord or cable assemblies or open conductors, or shall be run in raceways. All conductors shall be protected by overcurrent devices at their ampacity. Runs of open conductors shall be located where the conductors will not be subject to physical damage, and the conductors shall be fastened at intervals not exceeding 10 feet (3.05 m). No branch-circuit conductors shall be laid on the floor. Each branch circuit that supplies receptacles or fixed equipment shall contain a separate equipment grounding conductor if the branch circuit is run as open conductors.