Inspection 345882526 OPENED APR 7, 2022Closed
142 East 3450 North, Spanish Fork, UT 84660 · Medicinal and Botanical Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Young Living Essential Oils 6 times in Utah since 2000.
The latest one began on Apr 7, 2022 after a complaint, in Spanish Fork.
Those inspections ended with 26 citation items: 16 serious and 10 other-than-serious.
Penalties were first proposed at $14,630 and now stand at $12,205, 17% lower after settlements or reviews.
Respiratory protection comes up most often in these citations: 6 items under 1910.134.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Young Living Essential Oils averages $1,125 (1 cited inspection).
1 inspection on this page followed a fatal incident.
Utah · latest 90 days of OSHA records
73employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Utah
Checking a subcontractor, a client or your own company? Watch Young Living Essential Oils and get notified the morning OSHA posts a new citation for it.
Watch this company142 East 3450 North, Spanish Fork, UT 84660 · Medicinal and Botanical Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2089 Neways Drive, Springville, UT 84663 · Medicinal and Botanical Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
675 South 500 East, American Fork, UT 84003 · Medicinal and Botanical Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR UAC R614-1-5.F.1 |
Serious | $2,250 | $1,125 | Mar 9, 2021 | Final |
250 S Main St, Payson, UT 84651 · Other Direct Selling Establishments · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.106(d)(4)(i) · Flammable liquids |
Serious | $1,750 | $1,000 | Aug 3, 2005 | Final |
| Citation 1, item 2a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $1,100 | $550 | Aug 3, 2005 | Final |
| Citation 1, item 2b 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Aug 3, 2005 | Final |
250 S Main St, Payson, UT 84651 · OSHA's record · Phone and website on Google Maps
Incident on Aug 17, 2000 (fatal): Employee killed when struck by lid of pressure steamer
Employee #1 was in charge of monitoring the process of using steam to distill es sential oils from plant material. The 8 ft deep steam distillation vessel has an inner diameter of 89 1/2 in. and a conical-type lid that fastens on top. The ve ssel is positioned so that the lid joint is approximately 2 1/2 in. above the wo rking platform--waist level--so the operator can access it. Plant material is pl aced on top of a removable grate/screen, compacted, and secured before the lid i s fastened by a series of 12 strongback devices. Steam is then applied at the bo ttom at a pressure range of between 95 and 125 psi. The steam travels up through the material, extracting the essential oil, and then through a 10 in. wide open ing in the lid that tapers down to 2 1/2 in. before entering a cold water conden ser tube, where the oil/water vapor is converted to a liquid. The liquid is capt ured and run through a separator, where the essential oil is separated from the water for collection. The process lasts for approximately 2 1/2 hours. At the ti me of the accident, the material had been processing for between 40 and 45 minut es when, for some reason, the vessel began to overpressurize, causing a critical upset condition and a rupture at the lid/cover joint. Employee #1 was standing directly next to the vessel when the lid violently separated from it, dischargin g the pressure and material outward. He was struck in the head, and died as a re sult of his injuries.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 10005 D03 |
Serious | $1,350 | $1,350 | Dec 7, 2000 | Closed |
| Citation 1, item 2 29 CFR 10006 A |
Serious | $1,350 | $1,350 | Dec 7, 2000 | Closed |
| Citation 1, item 3a 29 CFR 1910.134(a)(2) · Respiratory protection |
Serious | $1,350 | $1,350 | Dec 7, 2000 | Closed |
| Citation 1, item 3b 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | Dec 7, 2000 | Closed |
| Citation 1, item 3c 29 CFR 1910.134(f)(1) · Respiratory protection |
Serious | $0 | $0 | Dec 7, 2000 | Closed |
| Citation 1, item 3d 29 CFR 1910.134(d)(1) · Respiratory protection |
Serious | $0 | $0 | Dec 7, 2000 | Closed |
| Citation 1, item 4 29 CFR 1910.146(c)(4) · Permit-required confined spaces |
Serious | $1,350 | $1,350 | Dec 7, 2000 | Closed |
| Citation 1, item 5 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $1,350 | $1,350 | Dec 7, 2000 | Closed |
| Citation 1, item 6 29 CFR 1910.219(e)(1) · Belts, pulleys and power-transmission parts |
Serious | $1,350 | $1,350 | Dec 7, 2000 | Closed |
| Citation 1, item 7 29 CFR 1910.252(c)(4)(i) · Welding fire safety |
Serious | $0 | $0 | Dec 7, 2000 | Closed |
| Citation 2, item 1a 29 CFR 10005 E11 |
Other-than-serious | $225 | $225 | Dec 7, 2000 | Closed |
| Citation 2, item 1b 29 CFR 1910.179(j)(2) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Dec 7, 2000 | Closed |
| Citation 2, item 1c 29 CFR 1910.179(j)(3) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Dec 7, 2000 | Closed |
| Citation 2, item 2 29 CFR 1910.212(b) · Machine guarding |
Other-than-serious | $190 | $190 | Dec 7, 2000 | Closed |
| Citation 2, item 3a 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Other-than-serious | $190 | $190 | Dec 7, 2000 | Closed |
| Citation 2, item 3b 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Dec 7, 2000 | Closed |
| Citation 2, item 3c 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Dec 7, 2000 | Closed |
| Citation 2, item 3d 29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Dec 7, 2000 | Closed |
| Citation 2, item 3e 29 CFR 1910.334(a)(2)(i) · Using electrical equipment |
Other-than-serious | $0 | $0 | Dec 7, 2000 | Closed |
| Citation 2, item 4 29 CFR 1910.1200(g)(8) · Hazard communication |
Other-than-serious | $225 | $225 | Dec 7, 2000 | Closed |
250 S Main St, Payson, UT 84651 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.134(a)(2) · Respiratory protection |
Serious | $600 | $600 | Aug 1, 2000 | Closed |
| Citation 1, item 1b 29 CFR 1910.134(d)(1)(iii) · Respiratory protection |
Serious | $0 | $0 | Aug 1, 2000 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(4)(i)
(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1910.1200(g)(8)
(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)
Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.