Inspection 345717011 OPENED JAN 8, 2022Closed
12320 Calm Pointe Court, Port Saint Lucie, FL 34953 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Yukon Construction Inc. has 8 OSHA inspections on record in Florida, the first in 2006.
OSHA's last visit started on Jan 8, 2022 as part of a related case, in Port Saint Lucie.
Across those inspections OSHA issued 11 citation items: 10 serious and 1 other-than-serious.
OSHA proposed $24,660 in penalties. After settlements and reviews the total is $15,341, down 38%.
Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Yukon Construction Inc. averages $3,417 over 2 cited inspections in that time.
Florida · latest 90 days of OSHA records
326employers cited
5 of them in the same industry
Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Florida
Checking a subcontractor, a client or your own company? Watch Yukon Construction Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company12320 Calm Pointe Court, Port Saint Lucie, FL 34953 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1806 N. Flamingo Road, Pembroke Pines, FL 33028 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(c)(2) · Scaffolds, general requirements |
Serious | $5,390 | $3,234 | Dec 1, 2015 | Final |
| Citation 1, item 2 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $2,200 | $1,320 | Dec 1, 2015 | Final |
| Citation 1, item 3 29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements |
Serious | $2,200 | $1,320 | Dec 1, 2015 | Final |
139 Tierra Lane, Jupiter, FL 33477 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $1,600 | $960 | Mar 18, 2015 | Final |
Cascada Isles Building #25, Cooper City, FL 33328 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $3,850 | $2,310 | Nov 1, 2012 | Final |
| Citation 1, item 2 29 CFR 1926.95(a) · Criteria for personal protective equipment |
Serious | $3,850 | $2,310 | Nov 1, 2012 | Final |
| Citation 2, item 1 29 CFR 1904.40(a) · Giving injury records to OSHA |
Other-than-serious | $770 | $462 | Nov 1, 2012 | Final |
4377 Cascada Circle, Cooper City, FL 33328 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2955 Nw 125th Avenue, Sunrise, FL 33323 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements |
Serious | $700 | $525 | Nov 2, 2006 | Closed |
| Citation 1, item 2 29 CFR 1926.452(c)(2) · Rules for each type of scaffold |
Serious | $700 | $525 | Nov 2, 2006 | Closed |
2955 Nw 125th Avenue, Sunrise, FL 33323 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements |
Serious | $900 | $675 | Feb 2, 2007 | Closed |
2955 Nw 125th Avenue, Sunrise, FL 33323 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps
Incident on Apr 6, 2006: Employee receives multiple fractures in fall from guardrail
On April 6, 2006, Employee #1 was cleaning concrete spoils off the existing slab from columns that had been formed and poured on the fourth floor of Building Nu mber 4 at the Artesia construction site. While scraping the concrete with a shov el, he lost his balance, causing him to lean on the guardrail system. The guardr ail system failed, which resulted in his fall from the fourth floor to a second floor. He fell approximately 24 ft, striking a second floor concrete slab pn the way down and sustaining multiple fractures across his body. Emergency medical p ersonnel were summoned. They arrived and transported him to a medical center. At the hospital, he underwent surgical procedures to repair the multiple fractures . After undergoing the surgical procedures, he was hospitalized for postoperativ e treatment. The investigaton revealed that the guardrail had been altered from the original installation to place the column forms and had not been sufficientl y fastened to the column forms once they had been installed.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.502(b)(3) · Fall protection systems |
Serious | $2,500 | $1,700 | Sep 1, 2006 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1904.40(a)
(a) Basic requirement. When an authorized government representative asks for the records you keep under part 1904, you must provide copies of the records within four (4) business hours.
29 CFR 1926.451(c)(2)
(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.
29 CFR 1926.451(c)(2)(ii)
(ii) Unstable objects shall not be used to support scaffolds or platform units.
Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.