Inspection 344796750 OPENED JUN 19, 2020Closed
Herbert St., Providence, RI 02909 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Johnston, Rhode Island · Masonry Contractors · NAICS 238140
OSHA has inspected Zeus Impex, LLC 2 times in Rhode Island since 2019.
The latest one began on Jun 19, 2020 after a complaint, in Providence.
Those inspections ended with 6 citation items: 6 serious.
Penalties were first proposed at $16,192 and now stand at $11,332, 30% lower after settlements or reviews.
Requirements for cast-in-place concrete comes up most often in these citations: 2 items under 1926.703.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Zeus Impex, LLC averages $11,332 (1 cited inspection).
Rhode Island · latest 90 days of OSHA records
83employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Rhode Island
Checking a subcontractor, a client or your own company? Watch Zeus Impex, LLC and get notified the morning OSHA posts a new citation for it.
Watch this companyHerbert St., Providence, RI 02909 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
64 Mill St., Johnston, RI 02919 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.20(b)(2) · Construction safety programs |
Serious | $4,048 | $2,833 | Mar 9, 2020 | Final |
| Citation 1, item 1b 29 CFR 1926.21(b)(2) · Construction safety training |
Serious | $0 | $0 | Mar 9, 2020 | Final |
| Citation 1, item 2a 29 CFR 1926.703(a)(1) · Requirements for cast-in-place concrete |
Serious | $4,048 | $2,833 | Mar 9, 2020 | Final |
| Citation 1, item 2b 29 CFR 1926.703(a)(2) · Requirements for cast-in-place concrete |
Serious | $0 | $0 | Mar 9, 2020 | Final |
| Citation 1, item 3 29 CFR 1926.754(a) · Structural steel assembly |
Serious | $4,048 | $2,833 | Mar 9, 2020 | Final |
| Citation 1, item 4 29 CFR 1926.850(a) · Preparatory operations |
Serious | $4,048 | $2,833 | Mar 9, 2020 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.20(b)(2)
(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.
29 CFR 1926.21(b)(2)
(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.
29 CFR 1926.703(a)(1)
(a) General requirements for formwork. (1) Formwork shall be designed, fabricated, erected, supported, braced and maintained so that it will be capable of supporting without failure all vertical and lateral loads that may reasonably be anticipated to be applied to the formwork. Formwork which is designed, fabricated, erected, supported, braced and maintained in conformance with the appendix to this section will be deemed to meet the requirements of this paragraph.
Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.