OSHA SearchOSHA records by employer

A. J. Manufacturing, Inc.: OSHA inspections and violations

Bloomer, Wisconsin · Metal Window and Door Manufacturing · NAICS 332321

15inspections
78citation items
$45,910current penalties
Feb 24, 2022last inspection

OSHA has inspected A. J. Manufacturing, Inc. 15 times in Wisconsin since 1997.

The latest one began on Feb 24, 2022 as a planned inspection, in Bloomer.

Those inspections ended with 78 citation items: 53 serious, 2 repeat and 23 other-than-serious.

Penalties were first proposed at $79,753 and now stand at $45,910, 42% lower after settlements or reviews.

Mechanical power presses comes up most often in these citations: 16 items under 1910.217.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and A. J. Manufacturing, Inc. averages $21,872 (1 cited inspection).

A. J. Manufacturing, Inc.: OSHA citation items per year, 1997 to 2022
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

229employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch A. J. Manufacturing, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345802268 OPENED FEB 24, 2022Closed

Planned · Complete · Safety · 100 employees at the site · Closed Dec 12, 2022

105 Riggs Street, Bloomer, WI 54724 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(i)(7) · Respiratory protection
Serious$6,340$3,804Jul 18, 2022Final
Citation 1, item 2a Serious$11,094$6,656Jul 18, 2022Final
Citation 1, item 2b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Jul 18, 2022Final
Citation 1, item 2c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Jul 18, 2022Final
Citation 1, item 3a
29 CFR 1910.147(d)(3) · Lockout/tagout
Serious$11,094$6,656Jul 18, 2022Final
Citation 1, item 3b
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$0$0Jul 18, 2022Final
Citation 1, item 4
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$7,925$4,755Jul 18, 2022Final

Inspection 336035993 OPENED AUG 28, 2012Closed

Follow-up · Partial · Safety · 80 employees at the site · Closed Aug 30, 2012

105 Riggs St., Bloomer, WI 54724 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 331099952 OPENED DEC 7, 2011Closed

Complaint · Partial · Health · 62 employees at the site · Closed Jun 6, 2012

105 Riggs Street, Bloomer, WI 54724 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$2,700$1,890Feb 28, 2012Final
Citation 1, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Feb 28, 2012Final
Citation 1, item 1c
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$0$0Feb 28, 2012Final
Citation 1, item 2a
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$4,500$3,150Feb 28, 2012Final
Citation 1, item 2b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Feb 28, 2012Final
Citation 1, item 2c
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Feb 28, 2012Final
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Feb 28, 2012Final
Citation 2, item 2
29 CFR 1910.252(c)(2)(ii) · Welding fire safety
Other-than-serious$0$0Feb 28, 2012Final

Inspection 106054455 OPENED JUL 10, 2007Closed

Programmed other · Partial · Safety · 40 employees at the site · Closed Jul 10, 2007

1217 Oak St., Bloomer, WI 54724 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307042374 OPENED FEB 21, 2007Closed

Planned · Complete · Safety · 40 employees at the site · Closed Sep 17, 2007

105 Riggs St., Bloomer, WI 54724 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$1,300$650Mar 30, 2007Closed
Citation 1, item 1b
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Serious$0$0Mar 30, 2007Closed
Citation 1, item 2a
29 CFR 1910.147(c)(4)(iib) · Lockout/tagout
Serious$1,625$813Mar 30, 2007Closed
Citation 1, item 2b
29 CFR 1910.147(d)(3) · Lockout/tagout
Serious$0$0Mar 30, 2007Closed
Citation 1, item 3
29 CFR 1910.151(c) · First aid and eyewash
Serious$1,300$650Mar 30, 2007Closed
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$975$488Mar 30, 2007Closed
Citation 1, item 5
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$2,275$1,137Mar 30, 2007Closed

Inspection 307041699 OPENED OCT 19, 2006Closed

Planned · Complete · Safety · 40 employees at the site · Closed Feb 9, 2007

1217 Oak St., Bloomer, WI 54724 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes
Serious$1,300$780Nov 22, 2006Closed
Citation 1, item 2
29 CFR 1910.147(c)(5)(iib) · Lockout/tagout
Serious$1,300$780Nov 22, 2006Closed
Citation 1, item 3
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Serious$1,625$975Nov 22, 2006Closed
Citation 1, item 4
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$1,625$975Nov 22, 2006Closed
Citation 1, item 5
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$975$0Nov 22, 2006Closed
Citation 1, item 6
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$1,300$780Nov 22, 2006Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Nov 22, 2006Closed
Citation 2, item 2
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Nov 22, 2006Closed
Citation 2, item 3
29 CFR 1910.219(e)(2)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Nov 22, 2006Closed

Inspection 300254471 OPENED DEC 1, 2003Closed

Planned · Complete · Safety · 54 employees at the site · Closed Feb 3, 2004

105 Riggs St. - North Plant, Bloomer, WI 54724 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$525$525Dec 16, 2003Closed
Citation 2, item 1
29 CFR 1910.217(b)(4)(iii) · Mechanical power presses
Repeat$200$200Dec 16, 2003Closed
Citation 3, item 1
29 CFR 1904.10(a) · Recording criteria for cases involving occupational hearing loss
Other-than-serious$0$0Dec 16, 2003Closed
Citation 3, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Other-than-serious$0$0Dec 16, 2003Closed
Citation 3, item 3
29 CFR 1910.217(c)(2)(ib) · Mechanical power presses
Other-than-serious$0$0Dec 16, 2003Closed
Citation 3, item 4
29 CFR 1910.1020(g)(1)(i) · Access to employee exposure and medical records
Other-than-serious$0$0Dec 16, 2003Closed
Citation 3, item 5
29 CFR 1910.1030(c)(1)(iv) · Bloodborne pathogens
Other-than-serious$0$0Dec 16, 2003Closed
Citation 3, item 6
29 CFR 1910.1030(g)(2)(iv) · Bloodborne pathogens
Other-than-serious$0$0Dec 16, 2003Closed

Inspection 300254489 OPENED DEC 1, 2003Closed

Planned · Complete · Safety · 46 employees at the site · Closed Feb 3, 2004

1217 Oak St., Bloomer, WI 54724 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$375$375Dec 16, 2003Closed
Citation 2, item 1
29 CFR 1910.217(c)(2)(ib) · Mechanical power presses
Repeat$200$200Dec 16, 2003Closed
Citation 3, item 1
29 CFR 1910.1020(g)(1)(i) · Access to employee exposure and medical records
Other-than-serious$0$0Dec 16, 2003Closed
Citation 3, item 2
29 CFR 1910.1030(c)(1)(iv) · Bloodborne pathogens
Other-than-serious$0$0Dec 16, 2003Closed
Citation 3, item 3
29 CFR 1910.1030(g)(2)(iv) · Bloodborne pathogens
Other-than-serious$0$0Dec 6, 2003Closed
7 older inspections

Inspection 106053937 OPENED NOV 26, 2002Closed

Complaint · Partial · Health · 45 employees at the site · Closed Jan 24, 2003

105 Riggs St. - North Plant, Bloomer, WI 54724 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,625$1,138Dec 23, 2002Closed
Citation 1, item 2
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Serious$975$682Dec 23, 2002Closed
Citation 2, item 1
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Other-than-serious$0$0Dec 23, 2002Closed

Inspection 106051428 OPENED AUG 16, 2001Closed

Planned · Partial · Safety · 45 employees at the site · Closed Sep 6, 2001

105 Riggs St. - North Plant, Bloomer, WI 54724 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Other-than-serious$0$0Aug 29, 2001Closed
Citation 1, item 2
29 CFR 1910.217(c)(2)(ib) · Mechanical power presses
Other-than-serious$0$0Aug 29, 2001Closed

Inspection 106055676 OPENED APR 17, 2001Closed

Planned · Partial · Safety · 46 employees at the site · Closed May 15, 2001

105 Riggs St., Bloomer, WI 54724 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$3,500$2,100Apr 20, 2001Closed
Citation 1, item 1b
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$0$0Apr 20, 2001Closed
Citation 1, item 2a
29 CFR 1910.217(b)(3)(i) · Mechanical power presses
Serious$675$405Apr 20, 2001Closed
Citation 1, item 2b
29 CFR 1910.217(b)(4)(i) · Mechanical power presses
Serious$0$0Apr 20, 2001Closed
Citation 1, item 2c
29 CFR 1910.217(b)(4)(iii) · Mechanical power presses
Serious$0$0Apr 20, 2001Closed
Citation 1, item 3
29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts
Serious$675$0Apr 20, 2001Closed

Inspection 106052871 OPENED JAN 13, 1998Closed

Planned · Complete · Safety · 47 employees at the site · Closed Feb 19, 1998

105 Riggs St., Bloomer, WI 54724 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$1,100$0Feb 4, 1998Closed

Inspection 106052889 OPENED JAN 13, 1998Closed

Planned · Complete · Safety · 58 employees at the site · Closed Mar 26, 1998

105 Riggs St. - North Plant, Bloomer, WI 54724 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,375$675Feb 4, 1998Closed
Citation 1, item 2a
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$825$415Feb 4, 1998Closed
Citation 1, item 2b
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Feb 4, 1998Closed
Citation 1, item 2c
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0Feb 4, 1998Closed
Citation 1, item 2d
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$0$0Feb 4, 1998Closed
Citation 2, item 1
29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes
Other-than-serious$0$0Feb 4, 1998Closed

Inspection 106052475 OPENED AUG 25, 1997Closed

Planned · Partial · Safety · 58 employees at the site · Closed Dec 10, 1997

105 Riggs St. - North Plant, Bloomer, WI 54724 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,375$720Sep 29, 1997Closed
Citation 1, item 2a
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$3,500$1,750Sep 29, 1997Closed
Citation 1, item 2b
29 CFR 1910.217(b)(4)(i) · Mechanical power presses
Serious$0$0Sep 29, 1997Closed
Citation 1, item 2c
29 CFR 1910.217(b)(5)(i) · Mechanical power presses
Serious$0$0Sep 29, 1997Closed
Citation 1, item 2d
29 CFR 1910.217(c)(2)(ia) · Mechanical power presses
Serious$0$0Sep 29, 1997Closed
Citation 1, item 2e
29 CFR 1910.217(e)(1)(ii) · Mechanical power presses
Serious$0$0Sep 29, 1997Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Sep 29, 1997Closed
Citation 2, item 2 Other-than-serious$0$0Sep 29, 1997Closed

Inspection 300245941 OPENED AUG 25, 1997Closed

Planned · Partial · Safety · 47 employees at the site · Closed Dec 10, 1997

105 Riggs St., Bloomer, WI 54724 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$2,750$1,375Sep 29, 1997Closed
Citation 1, item 1b
29 CFR 1910.217(b)(4)(i) · Mechanical power presses
Serious$0$0Sep 29, 1997Closed
Citation 1, item 1c
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$0$0Sep 29, 1997Closed
Citation 1, item 1d
29 CFR 1910.217(c)(2)(ia) · Mechanical power presses
Serious$0$0Sep 29, 1997Closed
Citation 1, item 1e
29 CFR 1910.217(e)(1)(ii) · Mechanical power presses
Serious$0$0Sep 29, 1997Closed
Citation 1, item 2a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$825$410Sep 29, 1997Closed
Citation 1, item 2b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Sep 29, 1997Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Sep 29, 1997Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.10 · Recording criteria for cases involving occupational hearing loss

29 CFR 1904.10(a)

(a) Basic requirement. If an employee's hearing test (audiogram) reveals that the employee has experienced a work-related Standard Threshold Shift (STS) in hearing in one or both ears, and the employee's total hearing level is 25 decibels (dB) or more above audiometric zero (averaged at 2000, 3000, and 4000 Hz) in the same ear(s) as the STS, you must record the case on the OSHA 300 Log.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.1020 · Access to employee exposure and medical records

29 CFR 1910.1020(g)(1)(i)

(i) The existence, location, and availability of any records covered by this section;

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1030(c)(1)(iv)

(iv) The Exposure Control Plan shall be reviewed and updated at least annually and whenever necessary to reflect new or modified tasks and procedures which affect occupational exposure and to reflect new or revised employee positions with occupational exposure. The review and update of such plans shall also:

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise

Other metal window and door manufacturing employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.