Inspection 348094293 OPENED MAR 10, 2025Closed
No citations from this inspection.
Philadelphia, Pennsylvania · Framing Contractors · NAICS 238130
Since 2021, OSHA inspectors have visited A Squared Construction LLC dba a Squared Framing in Pennsylvania 12 times.
The most recent inspection opened on Mar 10, 2025 to follow up on an earlier case.
In all, OSHA issued 18 citation items: 11 serious, 6 repeat and 1 other-than-serious.
The proposed penalties came to $332,536; today they stand at $307,436, 8% less.
The rule cited most here is 1926.501 (fall protection in construction), 5 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. A Squared Construction LLC dba a Squared Framing averages $51,239 across 6 cited inspections.
It reported 1 severe injury to OSHA since 2015.
Pennsylvania · latest 90 days of OSHA records
285employers cited
6 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch A Squared Construction LLC dba a Squared Framing and get notified the morning OSHA posts a new citation for it.
Watch this companyNo citations from this inspection.
918 N. Broad St., Philadelphia, PA 19130 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2139 North 6th Street, Philadelphia, PA 19122 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Repeat | $51,563 | $51,563 | Oct 18, 2023 | Final |
| Citation 1, item 2 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Repeat | $10,313 | $10,313 | Oct 18, 2023 | Final |
1901 E York St, Philadelphia, PA 19125 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(b)(2) · Scaffolds, general requirements |
Serious | $12,031 | $12,031 | Jun 29, 2023 | Final |
| Citation 1, item 2 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $12,031 | $12,031 | Jun 29, 2023 | Final |
| Citation 1, item 3 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Serious | $12,031 | $12,031 | Jun 29, 2023 | Final |
| Citation 1, item 4 29 CFR 1926.1053(a)(3)(i) · Ladders in construction |
Serious | $8,595 | $8,595 | Jun 29, 2023 | Final |
| Citation 1, item 5 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $12,031 | $12,031 | Jun 29, 2023 | Final |
| Citation 2, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Repeat | $60,156 | $60,156 | Jun 29, 2023 | Final |
1201 Vine Street, Philadelphia, PA 19107 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.20(b)(2) · Construction safety programs |
Serious | $6,875 | $6,875 | May 4, 2023 | Final |
| Citation 2, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Repeat | $34,375 | $34,375 | May 4, 2023 | Final |
2224 Germantown Ave, Philadelphia, PA 19133 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2702 Federal St, Philadelphia, PA 19146 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2100 Lombard St, Philadelphia, PA 19146 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Repeat | $23,928 | $17,000 | Dec 2, 2022 | Final |
2010 W Girard Ave, Philadelphia, PA 19130 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2410 Cypress St., Philadelphia, PA 19103 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
456-500 N 5th St, Philadelphia, PA 19123 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.21(b)(2) · Construction safety training |
Serious | $10,513 | $8,410 | Nov 9, 2021 | Final |
| Citation 1, item 2 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Serious | $10,513 | $8,410 | Nov 9, 2021 | Final |
| Citation 2, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Repeat | $52,564 | $42,051 | Nov 9, 2021 | Final |
| Citation 3, item 1 29 CFR 1904.40(a) · Giving injury records to OSHA |
Other-than-serious | $1,502 | $751 | Nov 9, 2021 | Final |
2601 Poplar Street, Philadelphia, PA 19130 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.200(g)(2) · Accident prevention signs and tags |
Serious | $4,505 | $3,604 | Aug 10, 2021 | Final |
| Citation 1, item 2 29 CFR 1926.453(b)(2)(iv) · Aerial lifts |
Serious | $4,505 | $3,604 | Aug 10, 2021 | Final |
| Citation 1, item 3 29 CFR 1926.453(b)(2)(v) · Aerial lifts |
Serious | $4,505 | $3,604 | Aug 10, 2021 | Final |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Apr 12, 2022, Philadelphia: Hospitalization · intracranial injuries, unspecified · brain
An employee fell through a floor hole cover on the third level of a building, landing on the concrete floor of the basement and suffering head trauma.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1904.40(a)
(a) Basic requirement. When an authorized government representative asks for the records you keep under part 1904, you must provide copies of the records within four (4) business hours.
29 CFR 1926.1053(a)(3)(i)
(3)(i) Rungs, cleats, and steps of portable ladders (except as provided below) and fixed ladders (including individual-rung/step ladders) shall be spaced not less than 10 inches (25 cm) apart, nor more than 14 inches (36 cm) apart, as measured between center lines of the rungs, cleats, and steps.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.