Abc Supply Co., Inc.: OSHA inspections and violations
Miami, Florida · Roofing, Siding, and Insulation Material Merchant Wholesalers · NAICS 423330
13inspections
10citation items
$56,143current penalties
Aug 8, 2024last inspection
Abc Supply Co., Inc. has 13 OSHA inspections on record in Florida, the first in 1989.
OSHA's last visit started on Aug 8, 2024 after a complaint, in Bradenton.
Across those inspections OSHA issued 10 citation items: 6 serious, 1 repeat and 3 other-than-serious.
OSHA proposed $93,352 in penalties. After settlements and reviews the total is $56,143, down 40%.
Most often, OSHA cited Section 5(a)(1), the General Duty Clause (2 items).
For context, across all wholesale employers the median penalty per cited inspection since 2015 is $3,425. Abc Supply Co., Inc. averages $25,657 over 2 cited inspections in that time.
1 inspection on this page followed a fatal incident.
Abc Supply Co., Inc. also files yearly injury logs with OSHA, summarized below.
It reported 2 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Florida · latest 90 days of OSHA records
326employers cited
Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.
OSHA records show Abc Supply Co., Inc. at 41 sites in 8 states. Together they've had 54 inspections and $250,615 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 41 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
Planned · Partial · Safety · 2 employees at the site · Closed Jan 11, 2018
4364 Ne 28th Street Lot 16e - Oak Hill Plantation, Ocala, FL 34471 · Roofing, Siding, and Insulation Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps
Incident on Dec 10, 2001 (fatal): One killed, one injured when boom conveyor hits power line
On December 10, 2001, Employees #1 and #2, who worked for different companies, w ere standing next to a truck delivering roofing materials. The operator of the b oom conveyor on the truck was moving it into position to load materials from the truck to the roof on a residential house. There were trees in the area that mad e moving the boom conveyor to the roof difficult and that contributed to it cont acting a 7620-volt power line. Employee #1, who was standing adjacent to the tru ck, was electrocuted. Employee #2, who was standing nearby, he received an elect ric shock; he sustained injuries that required hospitalization.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Jacksonville site logged 6 recordable injuries or illnesses among about 35 workers: 15.4 per 100 full-time workers, against a median of 3.5 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
ABC Supply 495
Jacksonville · 2025
35
6
0
15.4
3.5
ABC Supply 483
Tampa · 2025
37
1
1
2.6
3.5
ABC Supply 046
Tampa · 2025
32
2
0
5.4
3.5
ABC Supply 501
Lakeland · 2025
31
5
0
13.6
3.5
ABC Supply 050
Jacksonville · 2025
30
2
0
5.9
3.5
ABC Supply 494
Miami · 2025
29
2
1
6.6
3.5
ABC Supply 131
Ocala · 2025
23
3
1
10.7
3.5
ABC Supply 500
Cape Coral · 2025
27
0
0
0.0
3.5
Included with any plan: 74 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.
Sep 30, 2021, Lakeland: Hospitalization · fractures · neck and back
An employee was loading building materials onto a truck. As he stood in the bed, moving a knuckle boom crane's fork, the upright bar loosened and he fell off the truck. He suffered a neck/spinal fracture.
On 2/25/2015, an employee's left index finger was caught in a conveyor belt that was being used to move shingles to a rooftop and crushed but not severed.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.303 · Electrical equipment, general requirements
29 CFR 1910.303(g)(1)(i)
(i) Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized shall comply with the following dimensions, except as required or permitted elsewhere in this subpart:
(iii) Vehicular and mechanical equipment. (A) Any vehicle or mechanical equipment capable of having parts of its structure elevated near energized overhead lines shall be operated so that a clearance of 10 ft. (305 cm) is maintained. If the voltage is higher than 50kV, the clearance shall be increased 4 in. (10 cm) for every 10kV over that voltage. However, under any of the following conditions, the clearance may be reduced:
(a) Application. An employer must have an emergency action plan whenever an OSHA standard in this part requires one. The requirements in this section apply to each such emergency action plan.
Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.