OSHA SearchOSHA records by employer

Accu Machining Center, Inc.: OSHA inspections and violations

Easton, Pennsylvania · Machine Shops · NAICS 332710

5inspections
20citation items
$3,819current penalties
Feb 26, 2025last inspection

OSHA has inspected Accu Machining Center, Inc. 5 times in Pennsylvania since 1994.

The latest one began on Feb 26, 2025 as a planned inspection, in Easton.

Those inspections ended with 20 citation items: 10 serious and 10 other-than-serious.

Penalties were first proposed at $5,434 and now stand at $3,819, 30% lower after settlements or reviews.

Forklifts and other powered industrial trucks comes up most often in these citations: 3 items under 1910.178.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Accu Machining Center, Inc. averages $2,544 (1 cited inspection).

Accu Machining Center, Inc.: OSHA citation items per year, 1994 to 2025
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

280employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Accu Machining Center, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348066655 OPENED FEB 26, 2025Closed

Planned · No inspection · Safety · 8 employees at the site · Closed Mar 3, 2025

3750 Nicholas Street, Easton, PA 18045 · Machine Shops · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341143949 OPENED OCT 20, 2016Closed

Planned · Complete · Health · 11 employees at the site · Closed Mar 27, 2017

3750 Nicholas Street, Easton, PA 18045 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$1,817$1,272Nov 21, 2016Final
Citation 1, item 2
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$1,817$1,272Nov 21, 2016Final
Citation 2, item 1
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Nov 21, 2016Final
Citation 2, item 2
29 CFR 1910.1026(d)(1) · Hexavalent chromium
Other-than-serious$0$0Nov 21, 2016Final

Inspection 306575440 OPENED MAY 27, 2003Closed

Planned · Partial · Safety · 26 employees at the site · Closed Jun 27, 2003

187 N. Commerce Way, Lehigh Valley, PA 18002 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$525$275Jun 3, 2003Closed
Citation 1, item 1b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jun 3, 2003Closed
Citation 1, item 2
29 CFR 1910.242(b) · Hand and power tools
Serious$525$250Jun 3, 2003Closed

Inspection 122025125 OPENED MAY 30, 1996Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Jun 7, 1996

3750 Nicholas Street, Easton, PA 18045 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(q)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jun 5, 1996Closed
Citation 1, item 2
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jun 5, 1996Closed

Inspection 123257479 OPENED JUN 30, 1994Closed

Planned · Complete · Safety · 25 employees at the site · Closed Sep 26, 1995

3750 Nicholas Street, Easton, PA 18045 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$300$300Jul 6, 1994Closed
Citation 1, item 2
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Serious$225$225Jul 6, 1994Closed
Citation 1, item 3a
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$225$225Jul 6, 1994Closed
Citation 1, item 3b
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Jul 6, 1994Closed
Citation 1, item 3c
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$0$0Jul 6, 1994Closed
Citation 2, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Jul 6, 1994Closed
Citation 2, item 2
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Other-than-serious$0$0Jul 6, 1994Closed
Citation 2, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jul 6, 1994Closed
Citation 2, item 4
29 CFR 1910.1200(h)(1)(iii) · Hazard communication
Other-than-serious$0$0Jul 6, 1994Closed
Citation 2, item 5
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0Jul 6, 1994Closed
Citation 2, item 6
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Jul 6, 1994Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(d)(1)

(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other machine shops employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.