OSHA SearchOSHA records by employer

Accurate Steel Treating, Inc.: OSHA inspections and violations

South Gate, California · Metal Heat Treating · NAICS 332811

4inspections
38citation items
$16,000current penalties
Feb 18, 2020last inspection

Since 1989, OSHA inspectors have visited Accurate Steel Treating, Inc. in California 4 times.

The most recent inspection opened on Feb 18, 2020 as a planned inspection, in South Gate.

In all, OSHA issued 38 citation items: 17 serious and 21 other-than-serious.

The proposed penalties came to $20,560; today they stand at $16,000, 22% less.

The rule cited most here is 1910.178 (forklifts and other powered industrial trucks), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Accurate Steel Treating, Inc. averages $9,250 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Accurate Steel Treating, Inc. also files yearly injury logs with OSHA, summarized below.

Accurate Steel Treating, Inc.: OSHA citation items per year, 1989 to 2020
Citation items per year, by inspection date.

California · latest 90 days of OSHA records

1,134employers cited

Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in California

Checking a subcontractor, a client or your own company? Watch Accurate Steel Treating, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344641444 OPENED FEB 18, 2020Closed

Planned · Complete · Safety · 67 employees at the site · Closed Dec 14, 2020

10008 Miller Wy., South Gate, CA 90280 · Metal Heat Treating · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$325$125Apr 22, 2020Final
Citation 1, item 2
29 CFR 4650(E)
Other-than-serious$325$125Apr 22, 2020Final
Citation 2, item 1
29 CFR 3583(E)
Serious$2,925$2,250Apr 22, 2020Final
Citation 3, item 1
29 CFR 3480(A)
Serious$4,385$2,250Apr 22, 2020Final
Citation 4, item 1
29 CFR 5002
Serious$2,925$2,250Apr 22, 2020Final
Citation 5, item 1
29 CFR 5185(N)
Serious$2,925$2,250Apr 22, 2020Final

Inspection 310495353 OPENED MAY 12, 2009Closed

Accident · Partial · Safety · 55 employees at the site · Closed Oct 31, 2009

10008 Miller Way, South Gate, CA 90280 · Metal Heat Treating · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126167642 OPENED APR 6, 1999Closed

Accident · Partial · Safety · 43 employees at the site · Closed Nov 6, 1999

10008 Miller Way, South Gate, CA 90280 · OSHA's record · Phone and website on Google Maps

Incident on Feb 12, 1999: Employee's finger amputated by unguarded machine

At the time of the accident Employee #1 was working in the company's Rotoblast A rea. According to Employee #1, the machine had stopped while in operation. He tu rned off the machine, and then he removed the guard with the tools available to him. After seeing that the chain and sprocket were not the source of the problem , he restarted the machine. He took the guard to place it over the moving chain and sprocket. Then his finger was amputated when it was drawn into the pinch poi nt. Employee #1 was hospitalized. He had been trained in the operation of the ma chine, but not in the repair of the machine. The Spanish-speaking Employee #1 ha d received Lockout/Blockout training in English two months earlier. He had not b een instructed to take the guard off, but he had the tools to perform such work. Interviews showed that Lockout/Blockout training was performed, but only mainte nance personnel was trained and authorized to physically and electrically lockou t the machinery.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 3664 A
Other-than-serious$150$150Aug 9, 1999Closed
Citation 1, item 2 Other-than-serious$600$600Aug 9, 1999Closed
Citation 2, item 1
29 CFR 3314 A
Serious$2,000$2,000Aug 9, 1999Closed

Inspection 107276222 OPENED FEB 13, 1989Closed

Accident · Complete · Safety · 28 employees at the site · Closed Apr 24, 1989

10008 Miller Way, South Gate, CA 90280 · OSHA's record · Phone and website on Google Maps

Incident on Feb 13, 1989 (fatal): Employee killed when improperly secured hydraulic door falls

Employee #1 was checking inside a heat treating oven for leaks. He propped open the hydraulic door with a piece of pipe, leaving the hydraulic pressure still on in the downward position. The pipe slipped and the door fell on Employee #1's h ead, breaking his leg and neck and killing him.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$1,000$1,000Mar 23, 1989Closed
Citation 1, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$360$360Mar 23, 1989Closed
Citation 1, item 3
29 CFR 1910.26(c)(3)(iii) · Portable metal ladders
Serious$240$240Mar 23, 1989Closed
Citation 1, item 4
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$360$360Mar 23, 1989Closed
Citation 1, item 5
29 CFR 1910.151(c) · First aid and eyewash
Serious$240$240Mar 23, 1989Closed
Citation 1, item 6
29 CFR 1910.212(a)(5) · Machine guarding
Serious$300$300Mar 23, 1989Closed
Citation 1, item 7
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$240$240Mar 23, 1989Closed
Citation 1, item 8a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$420$420Mar 23, 1989Closed
Citation 1, item 8b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 23, 1989Closed
Citation 1, item 9
29 CFR 1910.243(c)(4) · Guarding of portable powered tools
Serious$240$240Mar 23, 1989Closed
Citation 1, item 10
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$240$240Mar 23, 1989Closed
Citation 1, item 11
29 CFR 1910.307(b) · Hazardous (classified) locations
Serious$240$240Mar 23, 1989Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$60$60Mar 23, 1989Closed
Citation 2, item 2
29 CFR 1904.5(a) · Determination of work-relatedness
Other-than-serious$60$60Mar 23, 1989Closed
Citation 2, item 3 Other-than-serious$0$0Mar 23, 1989Closed
Citation 2, item 4
29 CFR 1910.111(b)(10)(ii) · Storage and handling of anhydrous ammonia
Other-than-serious$0$0Mar 23, 1989Closed
Citation 2, item 5
29 CFR 1910.111(b)(10)(iii) · Storage and handling of anhydrous ammonia
Other-than-serious$0$0Mar 23, 1989Closed
Citation 2, item 6
29 CFR 1910.145(c)(3) · Specifications for accident prevention signs and tags
Other-than-serious$0$0Mar 23, 1989Closed
Citation 2, item 7
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Mar 23, 1989Closed
Citation 2, item 8
29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Mar 23, 1989Closed
Citation 2, item 9
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Mar 23, 1989Closed
Citation 2, item 10
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Mar 23, 1989Closed
Citation 2, item 11 Other-than-serious$0$0Mar 23, 1989Closed
Citation 2, item 12
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Mar 23, 1989Closed
Citation 2, item 13
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 23, 1989Closed
Citation 2, item 14
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Mar 23, 1989Closed
Citation 2, item 15
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Mar 23, 1989Closed
Citation 2, item 16
29 CFR 1910.1200(f)(4)(i) · Hazard communication
Other-than-serious$0$0Mar 23, 1989Closed
Citation 2, item 17
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Mar 23, 1989Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2020, the South Gate site logged 12 recordable injuries or illnesses among about 60 workers: 14.1 per 100 full-time workers, against a median of 3.2 for its industry. Those cases cost 31 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Accurate Steel Treating, Inc.
South Gate · 2020
60 121014.13.2

Included with any plan: 2 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1904.5 · Determination of work-relatedness

29 CFR 1904.5(a)

(a) Basic requirement. You must consider an injury or illness to be work-related if an event or exposure in the work environment either caused or contributed to the resulting condition or significantly aggravated a pre-existing injury or illness. Work-relatedness is presumed for injuries and illnesses resulting from events or exposures occurring in the work environment, unless an exception in § 1904.5(b)(2) specifically applies.

29 CFR 1910.111 · Storage and handling of anhydrous ammonia

29 CFR 1910.111(b)(10)(ii)

(ii) Stationary storage installations must have at least two suitable gas masks in readily-accessible locations. Full-face masks with ammonia canisters that have been approved by NIOSH under 42 CFR part 84 are suitable for emergency action involving most anhydrous ammonia leaks, particularly leaks that occur outdoors. For respiratory protection in concentrated ammonia atmospheres, a self-contained breathing apparatus is required.

29 CFR 1910.111(b)(10)(iii)

(iii) Stationary storage installations shall have an easily accessible shower or a 50-gallon drum of water.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.145 · Specifications for accident prevention signs and tags

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.26 · Portable metal ladders

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.94 · Ventilation

29 CFR 2500.10

29 CFR 2500.8

OSH Act Section 5 · General Duty Clause

Other metal heat treating employers in California

Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.