Advanced Composites, Inc.: OSHA inspections and violations
Sidney, Ohio · General Warehousing and Storage · NAICS 493110
5inspections
11citation items
$27,989current penalties
Dec 11, 2024last inspection
Advanced Composites, Inc. has 5 OSHA inspections on record in Ohio, the first in 2006.
OSHA's last visit started on Dec 11, 2024 on a referral, in Sidney.
Across those inspections OSHA issued 11 citation items: 6 serious and 5 other-than-serious.
OSHA proposed $33,164 in penalties. After settlements and reviews the total is $27,989, down 16%.
Most often, OSHA cited 1910.178, forklifts and other powered industrial trucks (3 items).
For context, across all transportation and warehousing employers the median penalty per cited inspection since 2015 is $3,560. Advanced Composites, Inc. averages $9,457 over 2 cited inspections in that time.
1 inspection on this page followed a fatal incident.
Advanced Composites, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 3 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Ohio · latest 90 days of OSHA records
273employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.
Incident on Mar 31, 2010 (fatal): Employee is killed when crushed by forklift
At approximately 8:15 a.m. on March 31, 2010, Employee #1 had been assigned to p ull boxes of products for shipping. The back of the forklift collided with a sta ck of boxes weighing approximately 4,500 lbs, displacing the stack approximately 18 inches. The forklift being operated was a Komatsu Model FG25ST-12, Type LP, and was equipped with a seat belt. The latch plate for the belt was tucked under the seat indicating that it was not used. Boxes were palletized, stored in stac ks, three high in most cases, and, three to four deep throughout the warehouse. Employee #1 was found caught between the right side of the forklift and a stack of large palletized boxes. Her injuries included multiple rib fractures and live r lacerations. She was pronounced dead at 8:30 a.m. and the cause of death was d etermined to be compression asphyxia.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2023, the Sidney site logged 1 recordable injury or illness among about 311 workers: 0.3 per 100 full-time workers, against a median of 1.6 for its industry. Those cases cost 6 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Advanced Composites Inc.
Sidney · 2023
311
1
1
0.3
1.6
Advanced Composites Inc. Ohio
Sidney · 2022
300
8
5
2.6
1.6
Advanced Composites Ohio Inc.
Sidney · 2021
350
7
3
2.1
1.6
Advanced Composites Inc. Ohio Plant
Sidney · 2021
250
7
3
2.1
1.6
Advanced Composits Inc.
Sidney · 2020
350
6
1
1.9
1.6
Included with any plan: 3 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 3 reports on file.
Apr 21, 2025, Sidney: Amputation · amputations involving bone loss · other finger(s) n.e.c.
On April 21, 2025, an employee was working to change the rubber leveling feet on an 180-pound mixing silo scale. After the leveling feet were replaced, the employee was removing a wood cribbing block that was used to support the raised scale, when the scale slipped. The second finger on the employee's left hand was crushed between one of the leveling feet and the wood block, resulting in amputation.
Dec 9, 2024, Sidney: Amputation · amputations involving bone loss · other finger(s) n.e.c.
An employee was working inside a silo room. As they went to clear plastic material (pellets) from the machine, they contacted the rotary valve at the bottom of the silo, resulting in the amputation of their left middle and ring fingers. The machine was not guarded and not locked out at the time.
Feb 7, 2024, Sidney: Amputation · amputations, avulsions, enucleations unspecified · other finger(s) n.e.c.
On February 7, 2024, at approximately 5:00 p.m., an employee was attempting to clean a pneumatically operated vacuum ball valve when their left index finger became caught in the ball and valve, resulting in an amputation of the finger pad. The machine was not locked out at the time of the incident.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(3) How quickly must each injury or illness be recorded? You must enter each recordable injury or illness on the OSHA 300 Log and 301 Incident Report within seven (7) calendar days of receiving information that a recordable injury or illness has occurred.
29 CFR 1910.132 · Personal protective equipment, general requirements
29 CFR 1910.132(a)
(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.
29 CFR 1910.132(d)(2)
(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.
Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.