Inspection 345597819 OPENED OCT 22, 2021Closed
1965 Bennett Drive, Deland, FL 32724 · Metal Tank (Heavy Gauge) Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2013, OSHA inspectors have visited Advanced Manufacturing & Power Systems, Inc. in Florida 6 times.
The most recent inspection opened on Oct 22, 2021 to follow up on an earlier case, in Deland.
In all, OSHA issued 10 citation items: 5 serious and 5 other-than-serious.
The proposed penalties came to $20,526; today they stand at $12,316, 40% less.
The rule cited most here is 1910.107 (spray painting and finishing), 5 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Advanced Manufacturing & Power Systems, Inc. averages $4,058 across 2 cited inspections.
Florida · latest 90 days of OSHA records
320employers cited
Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Florida
Checking a subcontractor, a client or your own company? Watch Advanced Manufacturing & Power Systems, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company1965 Bennett Drive, Deland, FL 32724 · Metal Tank (Heavy Gauge) Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1965 Bennett Drive, Deland, FL 32724 · Metal Tank (Heavy Gauge) Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 OSH Act Section 5(a)(1) · General Duty Clause |
Serious | $9,282 | $5,569 | Jun 10, 2019 | Final |
| Citation 2, item 1 29 CFR 1910.22(d)(1) · Walking-working surfaces |
Other-than-serious | $744 | $446 | Jun 10, 2019 | Final |
1965 Bennett Drive, Deland, FL 32724 · Metal Tank (Heavy Gauge) Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1965 Bennett Dr., Deland, FL 32724 · Motor Vehicle Electrical and Electronic Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1965 Bennett Dr., Deland, FL 32724 · Motor and Generator Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.107(g)(2) · Spray painting and finishing |
Serious | $2,100 | $2,100 | Mar 2, 2016 | Final |
1965 Bennett Drive, Deland, FL 32724 · Metal Tank (Heavy Gauge) Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.179(j)(1)(ii)(b) · Overhead and gantry cranes |
Serious | $2,800 | $1,400 | Feb 22, 2013 | Final |
| Citation 1, item 2 29 CFR 1910.179(l)(3)(iii)(d) · Overhead and gantry cranes |
Serious | $2,800 | $1,400 | Feb 22, 2013 | Final |
| Citation 1, item 3 29 CFR 1910.180(d)(1) · Crawler locomotive and truck cranes |
Serious | $2,800 | $1,400 | Feb 22, 2013 | Final |
| Citation 2, item 1a 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Feb 22, 2013 | Final |
| Citation 2, item 1b 29 CFR 1910.107(c)(2) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Feb 22, 2013 | Final |
| Citation 2, item 1c 29 CFR 1910.107(e)(2) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Feb 22, 2013 | Final |
| Citation 2, item 1d 29 CFR 1910.107(g)(7) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Feb 22, 2013 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(c)(2)
(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.
29 CFR 1910.107(e)(2)
(2) Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner.
Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.