OSHA SearchOSHA records by employer

Air Distributors, Inc.: OSHA inspections and violations

Dunnellon, Florida · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · NAICS 333415

5inspections
10citation items
$17,518current penalties
Nov 1, 2023last inspection

Since 2017, OSHA inspectors have visited Air Distributors, Inc. in Florida 5 times.

The most recent inspection opened on Nov 1, 2023 after a complaint, in Jacksonville.

In all, OSHA issued 10 citation items: 4 serious and 6 other-than-serious.

The proposed penalties came to $36,756; today they stand at $17,518, 52% less.

The rule cited most here is 1910.212 (machine guarding), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Air Distributors, Inc. averages $4,380 across 4 cited inspections.

It reported 2 severe injuries to OSHA since 2015.

Air Distributors, Inc.: OSHA citation items per year, 2017 to 2023
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Air Distributors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347073116 OPENED NOV 1, 2023Closed

Complaint · Partial · Safety · 3 employees at the site · Closed May 7, 2024

5355 Ramona Boulevard, Jacksonville, FL 32099 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Feb 7, 2024Final
Citation 1, item 2
29 CFR 1910.37(b)(5) · Exit routes
Other-than-serious$0$0Feb 7, 2024Final
Citation 1, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 7, 2024Final

Inspection 345445753 OPENED JUL 28, 2021Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Aug 6, 2021

1139 Eldridge St, Clearwater, FL 33755 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343675369 OPENED DEC 14, 2018Closed

Referral · Partial · Safety · 60 employees at the site · Closed Jun 19, 2019

2541 W. Dunnellon Rd, Dunnellon, FL 34433 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Dec 7, 2018: Employee strikes thumb against saw blade and amputates finge

At 2:30 p.m. on December 7, 2018, an employee was cutting an inch square metal tube with a Kyler Johnson Horizontal Bandsaw and put his right thumb by the saw blade before striking it. The employee amputated the tip of his thumb and was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Other-than-serious$18,564$6,603May 22, 2019Final

Inspection 343437455 OPENED AUG 28, 2018Closed

Complaint · Partial · Safety · 53 employees at the site · Closed Jan 17, 2019

2541 W. Dunnellon Rd, Dunnellon, FL 34433 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$6,467$3,880Jan 7, 2019Final
Citation 1, item 1b
29 CFR 1910.212(a)(3)(iii) · Machine guarding
Serious$0$0Jan 7, 2019Final

Inspection 342456928 OPENED JUL 10, 2017Closed

Referral · Partial · Safety · 42 employees at the site · Closed Dec 28, 2017

2541 W. Dunnellon Rd, Dunnellon, FL 34433 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jun 29, 2017: Employee's fingers are amputated while operating press brake

At approximately 3:02 p.m. on June 29, 2017, an employee was operating a press brake. While removing a part, the employee amputated three fingers on her left hand. The employee was not hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$5,387$3,232Dec 15, 2017Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$5,070$3,042Dec 15, 2017Final
Citation 2, item 1
29 CFR 1904.32(b)(3) · Yearly injury summary
Other-than-serious$1,268$761Dec 15, 2017Final
Citation 2, item 2
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Dec 15, 2017Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Dec 7, 2018, Dunnellon: Hospitalization, amputation · amputations · fingertip(s)

An employee was using a horizontal bandsaw. Their glove became caught pulling their hand/thumb into the blade. The employee suffered the amputation of the right thumb tip.

Jun 29, 2017, Dunnellon: Amputation · amputations · finger(s), fingernail(s), n.e.c.

An employee was bending metal on a brake press machine when the employee's left hand was caught in the machine, amputating the middle, ring, and pinky fingers.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(b)(3)

(3) How do I certify the annual summary? A company executive must certify that he or she has examined the OSHA 300 Log and that he or she reasonably believes, based on his or her knowledge of the process by which the information was recorded, that the annual summary is correct and complete.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.212(a)(3)(iii)

(iii) Special handtools for placing and removing material shall be such as to permit easy handling of material without the operator placing a hand in the danger zone. Such tools shall not be in lieu of other guarding required by this section, but can only be used to supplement protection provided.

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.37 · Exit routes

OSH Act Section 5 · General Duty Clause

Other air-conditioning and warm air heating equipment and commercial and industrial refrigeration equipment manufacturing employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.