OSHA SearchOSHA records by employer

All Plastics, LLC: OSHA inspections and violations

Addison, Texas · All Other Plastics Product Manufacturing · NAICS 326199

2inspections
14citation items
$38,914current penalties
Oct 30, 2023last inspection

Since 2018, OSHA inspectors have visited All Plastics, LLC in Texas 2 times.

The most recent inspection opened on Oct 30, 2023 as a planned inspection, in Addison.

In all, OSHA issued 14 citation items: 10 serious and 4 other-than-serious.

The proposed penalties came to $78,161; today they stand at $38,914, 50% less.

The rule cited most here is 1910.134 (respiratory protection), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. All Plastics, LLC averages $38,914 across 1 cited inspection.

All Plastics, LLC also files yearly injury logs with OSHA, summarized below.

All Plastics, LLC: OSHA citation items per year, 2018 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites All Plastics, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347070526 OPENED OCT 30, 2023Closed

Planned · No inspection · Health · Closed Oct 31, 2023

15700 Midway Rd., Addison, TX 75001 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343317392 OPENED JUL 19, 2018Closed

Planned · Partial · Health · 53 employees at the site · Closed Dec 5, 2019

15700 Midway Rd., Addison, TX 75001 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$11,641$6,985Nov 29, 2018Final
Citation 1, item 2 Serious$8,315$4,989Nov 29, 2018Final
Citation 1, item 3a
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$6,652$0Nov 29, 2018Final
Citation 1, item 3b
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Nov 29, 2018Final
Citation 1, item 3c
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0Nov 29, 2018Final
Citation 1, item 4
29 CFR 1910.151(c) · First aid and eyewash
Serious$8,315$4,989Nov 29, 2018Final
Citation 1, item 5
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$6,652$3,991Nov 29, 2018Final
Citation 1, item 6
29 CFR 1910.212(b) · Machine guarding
Serious$4,989$2,993Nov 29, 2018Final
Citation 1, item 7a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$6,652$3,991Nov 29, 2018Final
Citation 1, item 7b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Nov 29, 2018Final
Citation 1, item 8
29 CFR 1910.242(b) · Hand and power tools
Serious$6,652$3,991Nov 29, 2018Final
Citation 1, item 9
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$4,989$2,993Nov 29, 2018Final
Citation 1, item 10
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$6,652$3,991Nov 29, 2018Final
Citation 1, item 11
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$6,652$0Nov 29, 2018Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2020, the Addison site logged 2 recordable injuries or illnesses among about 45 workers: 4.9 per 100 full-time workers, against a median of 2.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Addison Location
Addison · 2020
45 204.92.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise

OSH Act Section 5 · General Duty Clause

Other all other plastics product manufacturing employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.