OSHA SearchOSHA records by employer

Alliance Machine and Engraving, LLC.: OSHA inspections and violations

Ashland, Virginia · Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers · NAICS 332812

2inspections
12citation items
$5,160current penalties
Jan 15, 2025last inspection

OSHA has inspected Alliance Machine and Engraving, LLC. 2 times in Virginia since 2024.

The latest one began on Jan 15, 2025 after a complaint, in Ashland.

Those inspections ended with 12 citation items: 7 serious and 5 other-than-serious.

Penalties were first proposed at $9,315 and now stand at $5,160, 45% lower after settlements or reviews.

Gas welding and cutting comes up most often in these citations: 2 items under 1910.253.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Alliance Machine and Engraving, LLC. averages $2,580 (2 cited inspections).

Alliance Machine and Engraving, LLC.: OSHA citation items per year, 2024 to 2025
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

250employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Alliance Machine and Engraving, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347978926 OPENED JAN 15, 2025Closed

Complaint · Partial · Health · 25 employees at the site · Closed Jun 2, 2025

10190 Maple Leaf Court, Ashland, VA 23005 · Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(c)(2) · Spray painting and finishing
Serious$670$670Apr 18, 2025Final
Citation 1, item 2
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$600$600Apr 18, 2025Final
Citation 2, item 1
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$0$0Apr 18, 2025Final
Citation 2, item 2
29 CFR 1910.134(k)(6) · Respiratory protection
Other-than-serious$0$0Apr 18, 2025Final

Inspection 347951899 OPENED DEC 27, 2024Closed

Referral · Partial · Safety · 24 employees at the site · Closed May 26, 2025

10190 Maple Leaf Court, Ashland, VA 23005 · Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$1,340$1,005Apr 14, 2025Final
Citation 1, item 1b
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$0$0Apr 14, 2025Final
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$1,340$0Apr 14, 2025Final
Citation 1, item 3
29 CFR 1910.212(a)(2) · Machine guarding
Serious$2,685$1,880Apr 14, 2025Final
Citation 1, item 4a
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$1,340$1,005Apr 14, 2025Final
Citation 1, item 4b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Apr 14, 2025Final
Citation 1, item 5a
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$1,340$0Apr 14, 2025Final
Citation 1, item 5b
29 CFR 1910.253(b)(5)(ii)(j) · Gas welding and cutting
Other-than-serious$0$0Apr 14, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(2)

(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.

29 CFR 1910.107(g)(7)

(7) “No Smoking” signs. “No smoking” signs in large letters on contrasting color background shall be conspicuously posted at all spraying areas and paint storage rooms.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(ii)

(ii) In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.253 · Gas welding and cutting

Other metal coating, engraving (except jewelry and silverware), and allied services to manufacturers employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.