OSHA SearchOSHA records by employer

Anchor Sales & Services Co. Inc.: OSHA inspections and violations

Independence, Missouri · Other Commercial and Service Industry Machinery Manufacturing · NAICS 333318

2inspections
9citation items
$10,282current penalties
Feb 15, 2024last inspection

OSHA has inspected Anchor Sales & Services Co. Inc. 2 times in Missouri since 2024.

The latest one began on Feb 15, 2024 after a complaint, in Independence.

Those inspections ended with 9 citation items: 9 serious.

Penalties were first proposed at $49,364 and now stand at $10,282, 79% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 2 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Anchor Sales & Services Co. Inc. averages $5,141 (2 cited inspections).

Anchor Sales & Services Co. Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Missouri · latest 90 days of OSHA records

124employers cited

Get notified the morning OSHA posts each new citation in Missouri: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Missouri

Checking a subcontractor, a client or your own company? Watch Anchor Sales & Services Co. Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347284929 OPENED FEB 15, 2024Closed

Complaint · Partial · Safety · 31 employees at the site · Closed Sep 18, 2024

106 West 31 Street South, Independence, MO 64055 · Other Commercial and Service Industry Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(q)(1) · Forklifts and other powered industrial trucks
Serious$9,680$2,056Jul 12, 2024Final
Citation 1, item 2a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$5,485$2,056Jul 12, 2024Final
Citation 1, item 2b
29 CFR 1910.305(a)(2)(x) · Electrical wiring methods
Serious$0$0Jul 12, 2024Final
Citation 1, item 2c
29 CFR 1910.303(g)(1)(i)(b) · Electrical equipment, general requirements
Serious$8,067$0Jul 12, 2024Final
Citation 1, item 2d
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$9,680$0Jul 12, 2024Final

Inspection 347285108 OPENED FEB 15, 2024Closed

Complaint · Complete · Health · 29 employees at the site · Closed Sep 24, 2024

106 West 31 Street South, Independence, MO 64055 · Other Commercial and Service Industry Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$4,113$2,056Jul 12, 2024Final
Citation 1, item 1b
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$4,113$0Jul 12, 2024Final
Citation 1, item 3
29 CFR 1910.253(b)(4)(i) · Gas welding and cutting
Serious$4,113$2,056Jul 12, 2024Final
Citation 1, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$4,113$2,056Jul 12, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(g)(2)

(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other other commercial and service industry machinery manufacturing employers in Missouri

Alert subscribers get notified of each newly cited employer in Missouri the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.