Appalachian Machine Inc.: OSHA inspections and violations

Dublin, Virginia · Machine Shops · NAICS 332710

8inspections
39citation items
$5,305current penalties
Dec 17, 2024last inspection

Appalachian Machine Inc. has 8 OSHA inspections on record in Virginia, the first in 1994.

OSHA's last visit started on Dec 17, 2024 as a planned inspection, in Dublin.

Across those inspections OSHA issued 39 citation items: 20 serious and 19 other-than-serious.

OSHA proposed $7,910 in penalties. After settlements and reviews the total is $5,305, down 33%.

Most often, OSHA cited 1910.134, respiratory protection (14 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Appalachian Machine Inc. averages $1,405 over 3 cited inspections in that time.

Appalachian Machine Inc.: OSHA citation items per year, 1994 to 2024
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

253employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Appalachian Machine Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347940298 OPENED DEC 17, 2024Closed

Planned · Complete · Safety · 24 employees at the site · Closed Mar 18, 2025

5304 Laboratory Rd, Dublin, VA 24084 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$705$494Jan 23, 2025Final
Citation 1, item 2a
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$705$494Jan 23, 2025Final
Citation 1, item 2b
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$0$0Jan 23, 2025Final
Citation 1, item 3a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$1,340$938Jan 23, 2025Final
Citation 1, item 3b
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Jan 23, 2025Final
Citation 2, item 1
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$0$0Jan 23, 2025Final

Inspection 347155178 OPENED DEC 11, 2023Closed

Complaint · Partial · Safety · 24 employees at the site · Closed Mar 15, 2024

5304 Laboratory Rd, Dublin, VA 24084 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Serious$600$420Jan 23, 2024Final
Citation 1, item 2
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$650$455Jan 23, 2024Final
Citation 2, item 1
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Jan 23, 2024Final
Citation 2, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jan 23, 2024Final

Inspection 343456414 OPENED SEP 12, 2018Closed

Planned · Complete · Health · 24 employees at the site · Closed Nov 30, 2018

5304 Laboratory Rd, Dublin, VA 24084 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$600$420Oct 5, 2018Final
Citation 1, item 1b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Oct 5, 2018Final
Citation 1, item 1c
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$0$0Oct 5, 2018Final
Citation 1, item 1d
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$0$0Oct 5, 2018Final
Citation 1, item 1e
29 CFR 1910.134(k)(5) · Respiratory protection
Serious$0$0Oct 5, 2018Final
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$600$420Oct 5, 2018Final
Citation 1, item 3
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$820$574Oct 5, 2018Final
Citation 2, item 1
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Oct 5, 2018Final
Citation 2, item 2
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Oct 5, 2018Final

Inspection 316861087 OPENED DEC 13, 2012Closed

Planned · Complete · Health · 19 employees at the site · Closed Aug 28, 2013

5304 Laboratory Street, Dublin, VA 24084 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$315$236Jan 3, 2013Closed
Citation 2, item 1
29 CFR 1910.107(e)(2) · Spray painting and finishing
Other-than-serious$0$0Jan 3, 2013Closed
Citation 2, item 2
29 CFR 1910.107(g)(2) · Spray painting and finishing
Other-than-serious$0$0Jan 3, 2013Closed
Citation 2, item 3
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Jan 3, 2013Closed
Citation 2, item 4
29 CFR 1910.134(f)(3) · Respiratory protection
Other-than-serious$0$0Jan 3, 2013Closed
Citation 2, item 5
29 CFR 1910.134(g)(1)(ia) · Respiratory protection
Other-than-serious$0$0Jan 3, 2013Closed
Citation 2, item 6
29 CFR 1910.134(k)(5) · Respiratory protection
Other-than-serious$0$0Jan 3, 2013Closed

Inspection 309674752 OPENED JAN 4, 2006Closed

Planned · Complete · Health · 20 employees at the site · Closed Jun 19, 2006

5304 Laboratory Street, Dublin, VA 24084 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Feb 2, 2006Closed
Citation 1, item 2
29 CFR 1910.107(g)(2) · Spray painting and finishing
Other-than-serious$0$0Feb 2, 2006Closed
Citation 1, item 3
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Feb 2, 2006Closed
Citation 1, item 4
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Feb 2, 2006Closed
Citation 1, item 5
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0Feb 2, 2006Closed
Citation 1, item 6
29 CFR 1910.134(k)(3) · Respiratory protection
Other-than-serious$0$0Feb 2, 2006Closed

Inspection 303093157 OPENED NOV 6, 2001Closed

Planned · Complete · Safety · 22 employees at the site · Closed Jan 7, 2002

5304 Laboratory Street, Dublin, VA 24084 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$375$250Dec 19, 2001Closed
Citation 1, item 2a
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$300$155Dec 19, 2001Closed
Citation 1, item 2b
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$0$0Dec 19, 2001Closed
Citation 2, item 1
29 CFR 1910.178(k)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Dec 19, 2001Closed
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Dec 19, 2001Closed

Inspection 300665056 OPENED JUL 15, 1999Closed

Planned · Partial · Safety · 15 employees at the site · Closed Jul 15, 1999

5304 Laboratory Street, Dublin, VA 24084 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 123697666 OPENED OCT 4, 1994Closed

Planned · Complete · Safety · 22 employees at the site · Closed Nov 28, 1994

5304 Laboratory Street, Dublin, VA 24084 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$450$225Oct 11, 1994Closed
Citation 1, item 2
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$450$225Oct 11, 1994Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(e)(2)

(2) Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner.

29 CFR 1910.107(g)(2)

(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.94 · Ventilation