Arrow Gear Company: OSHA inspections and violations
Downers Grove, Illinois · Aircraft Engine and Engine Parts Manufacturing · NAICS 336412
11inspections
34citation items
$10,680current penalties
Apr 19, 2018last inspection
Arrow Gear Company has 11 OSHA inspections on record in Illinois, the first in 1975.
OSHA's last visit started on Apr 19, 2018 on a referral, in Downers Grove.
Across those inspections OSHA issued 34 citation items: 17 serious, 1 repeat and 16 other-than-serious.
OSHA proposed $16,241 in penalties. After settlements and reviews the total is $10,680, down 34%.
Most often, OSHA cited 1910.94, ventilation (4 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Arrow Gear Company averages $7,500 over 1 cited inspection in that time.
Arrow Gear Company also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Illinois · latest 90 days of OSHA records
428employers cited
Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.
Incident on Apr 12, 2018: Employee is burned while working near pit furnace
At 1:15 p.m. on April 12, 2018, an employee was inserting a metal shim into the test chamber of a heat treating furnace. The employee leaned over the pit furnace and his shirt caught fire between the lid and the furnace, resulting in second and third degree burns to the torso area of his body. The employee was transported to the hospital and received medical treatment.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2023, the Downers Grove site logged 8 recordable injuries or illnesses among about 160 workers: 5.0 per 100 full-time workers, against a median of 2.3 for its industry. Those cases cost 383 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Arrow Gear Company
Downers Grove · 2023
160
8
8
5.0
2.3
Included with any plan: 2 more yearly logs from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(e)(2)
(2) Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner.
29 CFR 1910.110 · Storage and handling of liquefied petroleum gases
29 CFR 1910.132 · Personal protective equipment, general requirements
Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.