OSHA SearchOSHA records by employer

Arthur Products, Inc.: OSHA inspections and violations

Sparks, Nevada · Wood Window and Door Manufacturing · NAICS 321911

7inspections
12citation items
$7,540current penalties
Sep 26, 2016last inspection

Since 2013, OSHA inspectors have visited Arthur Products, Inc. in Nevada 7 times.

The most recent inspection opened on Sep 26, 2016 to follow up on an earlier case, in Sparks.

In all, OSHA issued 12 citation items: 6 serious and 6 other-than-serious.

The penalties, $7,540 in total, stand where OSHA first set them.

The rule cited most here is 1910.157 (portable fire extinguishers), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Arthur Products, Inc. averages $2,100 across 1 cited inspection.

Arthur Products, Inc.: OSHA citation items per year, 2013 to 2016
Citation items per year, by inspection date.

Nevada · latest 90 days of OSHA records

114employers cited

Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nevada

Checking a subcontractor, a client or your own company? Watch Arthur Products, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341801124 OPENED SEP 26, 2016Closed

Follow-up · Partial · Health · 11 employees at the site · Closed Sep 26, 2016

1555 Industrial Way, Sparks, NV 89431 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341064061 OPENED NOV 12, 2015Closed

Complaint · Partial · Health · 14 employees at the site · Closed Mar 8, 2022

1555 Industrial Way, Sparks, NV 89431 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(d)(2) · Spray painting and finishing
Serious$1,400$1,400Feb 22, 2016Final
Citation 1, item 2
29 CFR 1910.107(g)(3) · Spray painting and finishing
Serious$700$700Feb 22, 2016Final
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Feb 22, 2016Final

Inspection 340158039 OPENED DEC 30, 2014Closed

Referral · Partial · Safety · 13 employees at the site · Closed Dec 30, 2014

1492 Linda Way, Sparks, NV 89431 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340159037 OPENED DEC 30, 2014Closed

Referral · Partial · Health · 13 employees at the site · Closed Dec 30, 2014

1492 Linda Way, Sparks, NV 89431 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317618247 OPENED APR 8, 2014Closed

Unprogrammed related · Partial · Health · 18 employees at the site · Closed Apr 18, 2014

1492 Linda Way, Sparks, NV 89431 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317618304 OPENED APR 8, 2014Closed

Follow-up · Partial · Health · 18 employees at the site · Closed Dec 3, 2014

1492 Linda Way, Sparks, NV 89431 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317224715 OPENED AUG 20, 2013Closed

Referral · Complete · Health · 18 employees at the site · Closed Dec 16, 2014

1492 Linda Way, Sparks, NV 89431 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,360$1,360Dec 9, 2013Closed
Citation 1, item 2
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,360$1,360Dec 9, 2013Closed
Citation 1, item 3
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,700$1,700Dec 9, 2013Closed
Citation 1, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,020$1,020Dec 9, 2013Closed
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Dec 9, 2013Closed
Citation 2, item 2
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Dec 9, 2013Closed
Citation 2, item 3
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Dec 9, 2013Closed
Citation 2, item 4
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Dec 9, 2013Closed
Citation 2, item 5
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Dec 9, 2013Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(d)(2)

(2) General. All spraying areas shall be provided with mechanical ventilation adequate to remove flammable vapors, mists, or powders to a safe location and to confine and control combustible residues so that life is not endangered. Mechanical ventilation shall be kept in operation at all times while spraying operations are being conducted and for a sufficient time thereafter to allow vapors from drying coated articles and drying finishing material residue to be exhausted.

29 CFR 1910.107(g)(3)

(3) Residue disposal. Residue scrapings and debris contaminated with residue shall be immediately removed from the premises and properly disposed of. Approved metal waste cans shall be provided wherever rags or waste are impregnated with finishing material and all such rags or waste deposited therein immediately after use. The contents of waste cans shall be properly disposed of at least once daily or at the end of each shift.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.22 · General requirements

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 6180.3750

Other wood window and door manufacturing employers in Nevada

Alert subscribers get notified of each newly cited employer in Nevada the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.