OSHA SearchOSHA records by employer

Asher Cole, Inc.: OSHA inspections and violations

Phoenix, Arizona · Nonupholstered Wood Household Furniture Manufacturing · NAICS 337122

2inspections
30citation items
$7,500current penalties
Apr 14, 2016last inspection

Since 2007, OSHA inspectors have visited Asher Cole, Inc. in Arizona 2 times.

The most recent inspection opened on Apr 14, 2016 as a planned inspection, in Phoenix.

In all, OSHA issued 30 citation items: 11 serious and 19 other-than-serious.

The penalties, $7,500 in total, stand where OSHA first set them.

The rule cited most here is 1910.134 (respiratory protection), 7 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Asher Cole, Inc. averages $1,250 across 1 cited inspection.

Asher Cole, Inc.: OSHA citation items per year, 2007 to 2016
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

92employers cited

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch Asher Cole, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341408672 OPENED APR 14, 2016Closed

Planned · Complete · Safety · 27 employees at the site · Closed Sep 28, 2017

1146 W Hilton Ave, Phoenix, AZ 85007 · Custom Architectural Woodwork and Millwork Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,250$1,250Jun 20, 2016Final
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Jun 20, 2016Final
Citation 1, item 1c
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Jun 20, 2016Final
Citation 1, item 1d
29 CFR 1910.134(k)(1)(i) · Respiratory protection
Serious$0$0Jun 20, 2016Final
Citation 2, item 1
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jun 20, 2016Final

Inspection 311613921 OPENED NOV 7, 2007Closed

Planned · Complete · Health · 28 employees at the site · Closed Feb 19, 2008

1146 W. Hilton Avenue, Phoenix, AZ 85007 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$1,250$1,250Dec 26, 2007Closed
Citation 1, item 2a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$1,250$1,250Dec 26, 2007Closed
Citation 1, item 2b
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Dec 26, 2007Closed
Citation 1, item 2c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Dec 26, 2007Closed
Citation 1, item 3
29 CFR 1910.213(j)(3) · Woodworking machinery
Serious$1,250$1,250Dec 26, 2007Closed
Citation 1, item 4
29 CFR 1910.213(m)(1) · Woodworking machinery
Serious$1,250$1,250Dec 26, 2007Closed
Citation 1, item 5
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$1,250$1,250Dec 26, 2007Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 3
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 4
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 5
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 6
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 7
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 8
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 9
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 10
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 11
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 12
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 13
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 14
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 15
29 CFR 1910.305(g)(1)(iiia) · Electrical wiring methods
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 16
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 17
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Dec 26, 2007Closed
Citation 2, item 18
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 26, 2007Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.107(g)(7)

(7) “No Smoking” signs. “No smoking” signs in large letters on contrasting color background shall be conspicuously posted at all spraying areas and paint storage rooms.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other nonupholstered wood household furniture manufacturing employers in Arizona

Alert subscribers get notified of each newly cited employer in Arizona the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.