OSHA SearchOSHA records by employer

Ashland Woodworks, LLC: OSHA inspections and violations

Ashland, Virginia · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

3inspections
21citation items
$6,524current penalties
Jan 24, 2022last inspection

Since 2020, OSHA inspectors have visited Ashland Woodworks, LLC in Virginia 3 times.

The most recent inspection opened on Jan 24, 2022 on a referral, in Ashland.

In all, OSHA issued 21 citation items: 13 serious and 8 other-than-serious.

The proposed penalties came to $7,790; today they stand at $6,524, 16% less.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Ashland Woodworks, LLC averages $3,262 across 2 cited inspections.

1 inspection on this page followed a fatal incident.

Ashland Woodworks, LLC: OSHA citation items per year, 2020 to 2022
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

253employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Ashland Woodworks, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345740237 OPENED JAN 24, 2022Closed

Referral · Partial · Health · 25 employees at the site · Closed Jul 5, 2022

101 Henry Clay Road, Ashland, VA 23005 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Oct 6, 2021 (fatal): Employee with covid-19 infection dies

An employee was working in a wood kitchen cabinet and countertop manufacturer when he attended a non-work related communal event on September 9, and 11, 2021. The employee tested positive for COVID-19 on September 19, 2021 and did not return to work. The employee was admitted to the hospital on September 25, 2021 and remained in the hospital until he died on October 6, 2021.

No citations from this inspection.

Inspection 345727580 OPENED JAN 14, 2022Closed

Planned · Complete · Safety · 25 employees at the site · Closed May 27, 2022

101 Henry Clay Road, Ashland, VA 23005 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(c)(5) · Spray painting and finishing
Serious$1,190$1,190Apr 5, 2022Final
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$1,190$1,190Apr 5, 2022Final
Citation 1, item 3a
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$1,190$1,190Apr 5, 2022Final
Citation 1, item 3b
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Apr 5, 2022Final
Citation 1, item 3c
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Apr 5, 2022Final
Citation 2, item 1 Other-than-serious$0$0Apr 5, 2022Final
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Apr 5, 2022Final
Citation 2, item 3
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Apr 5, 2022Final
Citation 2, item 4
29 CFR 1910.303(g)(1)(i)(a) · Electrical equipment, general requirements
Other-than-serious$0$0Apr 5, 2022Final
Citation 2, item 5
29 CFR 1910.305(a)(2)(ix) · Electrical wiring methods
Other-than-serious$0$0Apr 5, 2022Final
Citation 2, item 6
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Other-than-serious$0$0Apr 5, 2022Final

Inspection 344640008 OPENED FEB 20, 2020Closed

Planned · Complete · Health · 20 employees at the site · Closed Jul 21, 2020

101 Henry Clay Rd., Ashland, VA 23005 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$840$588Apr 15, 2020Final
Citation 1, item 2a
29 CFR 1910.107(c)(2) · Spray painting and finishing
Serious$840$588Apr 15, 2020Final
Citation 1, item 2b
29 CFR 1910.107(g)(5) · Spray painting and finishing
Serious$0$0Apr 15, 2020Final
Citation 1, item 3a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$840$588Apr 15, 2020Final
Citation 1, item 3b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Apr 15, 2020Final
Citation 1, item 3c
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$0$0Apr 15, 2020Final
Citation 1, item 4
29 CFR 1910.151(b) · First aid and eyewash
Serious$600$420Apr 15, 2020Final
Citation 1, item 5 Serious$1,100$770Apr 15, 2020Final
Citation 2, item 1
29 CFR 1910.36(d)(2) · Exit route design
Other-than-serious$0$0Apr 15, 2020Final
Citation 2, item 2
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Apr 15, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1048 · Formaldehyde

29 CFR 1910.1048(d)(1)(i)

(d) Exposure monitoring—(1) General. (i) Each employer who has a workplace covered by this standard shall monitor employees to determine their exposure to formaldehyde.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(2)

(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.

29 CFR 1910.107(c)(5)

(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.94 · Ventilation

Other wood kitchen cabinet and countertop manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.