OSHA SearchOSHA records by employer

Mueller & Mueller, Inc.: OSHA inspections and violations

Ashland, Virginia · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

2inspections
11citation items
$7,308current penalties
Sep 28, 2026last inspection

Since 2022, OSHA inspectors have visited Mueller & Mueller, Inc. in Virginia 2 times.

The most recent inspection opened on Sep 28, 2026 on a referral, in Ashland and is still open.

In all, OSHA issued 11 citation items: 10 serious and 1 other-than-serious.

The proposed penalties came to $14,650; today they stand at $7,308, 50% less.

The rule cited most here is 1910.107 (spray painting and finishing), 6 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Mueller & Mueller, Inc. averages $7,308 across 1 cited inspection.

Mueller & Mueller, Inc.: OSHA citation items per year, 2022 to 2026
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

249employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Mueller & Mueller, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 349186981 OPENED SEP 28, 2026Open

Referral · Partial · Safety · 74 employees at the site · Open

The Closet Factory 10520 Lakeridge Parkway, Suite A, Ashland, VA 23005 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 346315799 OPENED NOV 1, 2022Closed

Complaint · Partial · Health · 28 employees at the site · Closed Nov 27, 2023

The Closet Factory 10520 Lakeridge Parkway, Suite A, Ashland, VA 23005 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(11) · Ladders in general industry
Serious$3,620$2,896Mar 8, 2023Final
Citation 1, item 2a
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$3,620$0Mar 8, 2023Final
Citation 1, item 2b
29 CFR 1910.29(k)(1) · Fall protection systems in general industry
Serious$0$0Mar 8, 2023Final
Citation 1, item 3a
29 CFR 1910.107(b)(1) · Spray painting and finishing
Serious$3,620$2,896Mar 8, 2023Final
Citation 1, item 3b
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$0$0Mar 8, 2023Final
Citation 1, item 3c
29 CFR 1910.107(f)(3) · Spray painting and finishing
Serious$0$0Mar 8, 2023Final
Citation 1, item 4a
29 CFR 1910.107(d)(3) · Spray painting and finishing
Serious$1,895$0Mar 8, 2023Final
Citation 1, item 4b
29 CFR 1910.107(d)(8) · Spray painting and finishing
Serious$0$0Mar 8, 2023Final
Citation 1, item 4c
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Mar 8, 2023Final
Citation 1, item 5
29 CFR 1910.110(f)(2)(i) · Storage and handling of liquefied petroleum gases
Serious$1,895$1,516Mar 8, 2023Final
Citation 2, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Mar 8, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(1)

(b) Spray booths—(1) Construction. Spray booths shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet.

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.107(d)(3)

(3) Independent exhaust. Each spray booth shall have an independent exhaust duct system discharging to the exterior of the building, except that multiple cabinet spray booths in which identical spray finishing material is used with a combined frontal area of not more than 18 square feet may have a common exhaust. If more than one fan serves one booth, all fans shall be so interconnected that one fan cannot operate without all fans being operated.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.23 · Ladders in general industry

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.29 · Fall protection systems in general industry

Other wood kitchen cabinet and countertop manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.