Atlantic Refinishing & Restoration, Inc.: OSHA inspections and violations
Waldorf, Maryland · Tile and Terrazzo Contractors · NAICS 238340
4inspections
26citation items
$3,170current penalties
Nov 12, 2025last inspection
Since 1994, OSHA inspectors have visited Atlantic Refinishing & Restoration, Inc. in Maryland 4 times.
The most recent inspection opened on Nov 12, 2025 after a complaint, in Beltsville.
In all, OSHA issued 26 citation items: 14 serious and 12 other-than-serious.
The proposed penalties came to $5,850; today they stand at $3,170, 46% less.
The rule cited most here is 1910.107 (spray painting and finishing), 9 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Atlantic Refinishing & Restoration, Inc. averages $1,440 across 1 cited inspection.
Atlantic Refinishing & Restoration, Inc. also files yearly injury logs with OSHA, summarized below.
The Wage and Hour Division has 7 cases on it since 2015, with $165,431 in back wages owed to workers.
Citation items per year, by inspection date.
Maryland · latest 90 days of OSHA records
178employers cited
Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Atlantic Refinishing & Restoration, Inc. and get notified the morning OSHA posts a new citation for it.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2023, the Beltsville site logged 2 recordable injuries or illnesses among about 306 workers: 0.9 per 100 full-time workers, against a median of 2.8 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Atlantic Restoration & Waterproofing, Inc.
Beltsville · 2023
306
2
0
0.9
2.8
Wage and hour cases
Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.
Period reviewed
Violations
Workers owed
Back wages
Penalties
Sep 15, 2021 to Sep 17, 2022
Beltsville
96
52
$73,607
$0
Apr 16, 2021 to Jun 30, 2021
BELTSVILLE
2
2
$5,141
$0
Jan 6, 2020 to Oct 20, 2020
Beltsville
39
20
$17,137
$0
Feb 20, 2018 to Feb 19, 2020
Beltsville
21
7
$46,433
$0
Oct 6, 2019 to Jan 6, 2020
Beltsville
7
7
$4,364
$0
Aug 18, 2017 to Aug 18, 2019
Waldorf
3
0
$0
$0
Apr 13, 2014 to May 12, 2015
Waldorf
13
13
$18,749
$0
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(b)(5)(iv)
(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.
Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.