OSHA SearchOSHA records by employer

Atlas Iron Works: OSHA inspections and violations

St. Louis, Missouri · Fabricated Structural Metal Manufacturing · NAICS 332312

7inspections
41citation items
$15,322current penalties
May 16, 2024last inspection

Since 1982, OSHA inspectors have visited Atlas Iron Works in Missouri 7 times.

The most recent inspection opened on May 16, 2024 after a complaint, in Saint Louis.

In all, OSHA issued 41 citation items: 34 serious and 7 other-than-serious.

The proposed penalties came to $25,690; today they stand at $15,322, 40% less.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Atlas Iron Works averages $4,610 across 1 cited inspection.

Atlas Iron Works also files yearly injury logs with OSHA, summarized below.

Atlas Iron Works: OSHA citation items per year, 1982 to 2024
Citation items per year, by inspection date.

Missouri · latest 90 days of OSHA records

118employers cited

Get notified the morning OSHA posts each new citation in Missouri: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Missouri

Checking a subcontractor, a client or your own company? Watch Atlas Iron Works and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347485047 OPENED MAY 16, 2024Closed

Complaint · Partial · Health · 15 employees at the site · Closed Mar 3, 2025

4020 Geraldine Avenue, Saint Louis, MO 63115 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$4,610$2,305Oct 16, 2024Final
Citation 1, item 2
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Serious$4,610$2,305Oct 16, 2024Final
Citation 2, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 16, 2024Final
Citation 2, item 2
29 CFR 1910.1200(g)(10) · Hazard communication
Other-than-serious$0$0Oct 16, 2024Final

Inspection 332838473 OPENED MAR 15, 2012Closed

Planned · Partial · Safety · 22 employees at the site · Closed Sep 20, 2012

4020 Geraldine Avenue, Saint Louis, MO 63115 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,800$1,260Aug 30, 2012Final
Citation 1, item 1b
29 CFR 1910.134(e)(2)(i) · Respiratory protection
Serious$0$0Aug 30, 2012Final
Citation 1, item 1c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Aug 30, 2012Final
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$2,400$1,680Aug 30, 2012Final
Citation 1, item 3
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$2,400$1,680Aug 30, 2012Final
Citation 1, item 4a
29 CFR 1910.303(e)(1)(ii) · Electrical equipment, general requirements
Serious$1,800$1,260Aug 30, 2012Final
Citation 1, item 4b
29 CFR 1910.303(f)(1) · Electrical equipment, general requirements
Serious$0$0Aug 30, 2012Final
Citation 1, item 4c
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$0$0Aug 30, 2012Final
Citation 1, item 5
29 CFR 1910.1200(e) · Hazard communication
Serious$1,800$1,260Aug 30, 2012Final
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Aug 30, 2012Final

Inspection 304321557 OPENED JUN 27, 2001Closed

Planned · Complete · Safety · 28 employees at the site · Closed Dec 21, 2001

4020 Geraldine Ave, St. Louis, MO 63115 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.133(a)(5) · Eye and face protection
Serious$525$262Sep 27, 2001Closed
Citation 1, item 1b
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$0$0Sep 27, 2001Closed
Citation 1, item 2
29 CFR 1910.178(n)(4) · Forklifts and other powered industrial trucks
Serious$700$350Sep 27, 2001Closed
Citation 1, item 3
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Serious$700$350Sep 27, 2001Closed
Citation 1, item 4a Serious$700$350Sep 27, 2001Closed
Citation 1, item 4b Serious$0$0Sep 27, 2001Closed
Citation 1, item 5a
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$875$438Sep 26, 2001Closed
Citation 1, item 5b
29 CFR 1910.212(a)(1) · Machine guarding
Serious$0$0Sep 27, 2001Closed
Citation 1, item 5c
29 CFR 1910.212(a)(5) · Machine guarding
Serious$0$0Sep 27, 2001Closed
Citation 1, item 6
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$700$350Sep 27, 2001Closed
Citation 1, item 7a
29 CFR 1910.303(b)(1)(iii) · Electrical equipment, general requirements
Serious$875$438Sep 27, 2001Closed
Citation 1, item 7b
29 CFR 1910.303(e) · Electrical equipment, general requirements
Serious$0$0Sep 27, 2001Closed
Citation 1, item 7c
29 CFR 1910.305(a)(2)(iiif) · Electrical wiring methods
Serious$0$0Sep 27, 2001Closed
Citation 1, item 7d
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Sep 27, 2001Closed
Citation 1, item 7e
29 CFR 1910.334(a)(3)(ii) · Using electrical equipment
Serious$0$0Sep 27, 2001Closed
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Sep 27, 2001Closed
Citation 2, item 2
29 CFR 1910.179(d)(4)(iii) · Overhead and gantry cranes
Other-than-serious$0$0Sep 27, 2001Closed

Inspection 109583351 OPENED APR 22, 1999Closed

Planned · No inspection · Safety · Closed Apr 22, 1999

4020 Geraldine Ave, St. Louis, MO 63115 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109532010 OPENED JUN 7, 1996Closed

Complaint · Partial · Health · 28 employees at the site · Closed Feb 7, 1997

4020 Geraldine Ave, St. Louis, MO 63115 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(c)(2) · Spray painting and finishing
Serious$875$875Oct 16, 1996Closed
Citation 1, item 1b
29 CFR 1910.107(c)(3) · Spray painting and finishing
Serious$0$0Oct 16, 1996Closed
Citation 1, item 1c
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Oct 16, 1996Closed
Citation 1, item 1d
29 CFR 1910.107(c)(7) · Spray painting and finishing
Serious$0$0Oct 16, 1996Closed
Citation 1, item 1e
29 CFR 1910.107(e)(5) · Spray painting and finishing
Serious$0$0Oct 16, 1996Closed
Citation 2, item 1
29 CFR 1910.134(b)(1) · Respiratory protection
Other-than-serious$0$0Oct 16, 1996Closed
Citation 2, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Oct 16, 1996Closed

Inspection 1461318 OPENED FEB 12, 1985Closed

Planned · Complete · Safety · 14 employees at the site · Closed Feb 13, 1985

4020 Geraldine Ave, St Louis, MO 63115 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 217672351 OPENED APR 28, 1982Closed

Planned · Complete · Safety · 15 employees at the site · Closed Oct 1, 1982

4020 Geraldine Ave, St Louis, MO 63115 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.179(f)(1)(i) · Overhead and gantry cranes
Serious$320$160Jun 3, 1982Closed
Citation 1, item 1c Serious$0$0May 7, 1982Closed
Citation 1, item 1d Serious$0$0May 7, 1982Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2021, the St. Louis site logged 0 recordable injuries or illnesses among about 20 workers: 0.0 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Atlas Iron Works, Inc.
St. Louis · 2021
20 000.03.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(2)

(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.

29 CFR 1910.107(c)(3)

(3) Hot surfaces. Space-heating appliances, steampipes, or hot surfaces shall not be located in a spraying area where deposits of combustible residues may readily accumulate.

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.95 · Noise

Other fabricated structural metal manufacturing employers in Missouri

Alert subscribers get notified of each newly cited employer in Missouri the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.