Inspection 346107410 OPENED JUL 27, 2022Closed
9001 Ambassador Row, Dallas, TX 75247 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Atrium Windows and Doors 8 times in Texas since 2014.
The latest one began on Jul 27, 2022 to follow up on an earlier case, in Dallas.
Those inspections ended with 14 citation items: 9 serious and 5 other-than-serious.
Penalties were first proposed at $154,733 and now stand at $73,625, 52% lower after settlements or reviews.
Lockout/tagout comes up most often in these citations: 5 items under 1910.147.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Atrium Windows and Doors averages $12,406 (4 cited inspections).
2 inspections on this page followed a fatal incident.
Atrium Windows and Doors also files yearly injury logs with OSHA, summarized below.
It reported 2 severe injuries to OSHA since 2015.
Texas · latest 90 days of OSHA records
391employers cited
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Atrium Windows and Doors and get notified the morning OSHA posts a new citation for it.
Watch this companyOSHA records show Atrium Windows and Doors at 4 sites in 2 states. Together they've had 9 inspections and $75,575 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 4 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
See plans9001 Ambassador Row, Dallas, TX 75247 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
9001 Ambassador Row, Dallas, TX 75247 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Other-than-serious | $13,653 | $13,653 | Nov 4, 2021 | Final |
9001 Ambassador Row, Dallas, TX 75247 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Jan 9, 2021 (fatal): Employee with covid-19 infection dies
An employee worked in the Glass department. At his workstation, he spoke to the line lead when given work instructions and other employees who would bring him glass in carts for processing in the production line. The employee reported to his work station on December 22, 2020, and was admitted to the hospital the same day for positive COVID-19 treatment. He died on January 9, 2021, while in the hospital due to complications of COVID-19.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1904.4(a) · Recording criteria |
Other-than-serious | $2,146 | $11,505 | Jul 6, 2021 | Final |
1223 Tappan Circle, Carrollton, TX 75006 · Unlaminated Plastics Profile Shape Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1223 Tappan Circle, Carrollton, TX 75006 · Unlaminated Plastics Profile Shape Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.95(c)(1) · Noise |
Serious | $12,934 | $6,467 | Oct 24, 2018 | Final |
9001 Ambassador Row, Dallas, TX 75247 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $7,000 | $7,000 | Jul 29, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.147(c)(6)(ii) · Lockout/tagout |
Serious | $38,500 | $5,500 | Jul 29, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.147(c)(7)(i)(b) · Lockout/tagout |
Other-than-serious | $38,500 | $5,500 | Jul 29, 2016 | Final |
930 Hensley Ln, Wylie, TX 75098 · Alumina and Aluminum Production and Processing · OSHA's record · Phone and website on Google Maps
Incident on Nov 22, 2014 (fatal): Employee caught in machinery and is killed
At 2:00 a.m. on November 22, 2014, an employee had just completed the installation of an idler shaft for a low puller that was part of a material handling system for an aluminum extrusion operation. The employee stepped up onto a hot saw platform and got in the saw's path just prior to the saw making a cut of extruded aluminum. The employee became caught between the hydraulically-controlled carriage of the saw and cooling ducts. The employee was killed due to traumatic asphyxia.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $7,000 | $3,700 | May 20, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(7)(i)(b) · Lockout/tagout |
Other-than-serious | $7,000 | $3,700 | May 20, 2015 | Final |
| Citation 1, item 3 OSH Act Section 5(a)(1) · General Duty Clause |
Serious | $7,000 | $7,000 | May 20, 2015 | Final |
9001 Ambassador Row, Dallas, TX 75247 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 3 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Other-than-serious | $5,000 | $1,600 | Dec 5, 2014 | Final |
| Citation 1, item 4 29 CFR 1926.25(a) · Housekeeping |
Serious | $4,000 | $2,000 | Dec 5, 2014 | Final |
| Citation 1, item 6 29 CFR 1926.403(b)(2) · Electrical equipment on job sites |
Serious | $4,000 | $2,000 | Dec 5, 2014 | Final |
| Citation 1, item 7 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Serious | $4,000 | $2,000 | Dec 5, 2014 | Final |
| Citation 1, item 8 29 CFR 1926.405(g)(2)(iv) · Job-site wiring |
Serious | $4,000 | $2,000 | Dec 5, 2014 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Dallas site logged 3 recordable injuries or illnesses among about 448 workers: 0.6 per 100 full-time workers, against a median of 2.6 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Atrium Windows and Doors Dallas · 2025 | 448 | 3 | 0 | 0.6 | 2.6 |
| North Texas Plant Dallas · 2021 | 800 | 26 | 13 | 2.9 | 3.6 |
Included with any plan: 6 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansEmployers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.
Jun 8, 2021, Dallas: Hospitalization · soreness, pain, hurt-nonspecified injury · leg(s), unspecified
An employee was cleaning rollers on a roller oven. He was pulled into the box of the oven, suffering injuries to the right leg.
Mar 24, 2016, Dallas: Amputation · amputations · finger(s), fingernail(s), n.e.c.
While cutting aluminum on a saw, an employee sustained a right middle finger amputation.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1904.4(a)
(a) Basic requirement. Each employer required by this part to keep records of fatalities, injuries, and illnesses must record each fatality, injury and illness that:
29 CFR 1910.147(c)(4)(i)
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(6)(i)
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.