Inspection 344516513 OPENED NOV 6, 2019Closed
86 Lake Cynthia Rd, Blackville, SC 29817 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Blackville, South Carolina · All Other Plastics Product Manufacturing · NAICS 326199
Augusta Fiberglass Coatings Inc has 12 OSHA inspections on record in South Carolina, the first in 1991.
OSHA's last visit started on Nov 6, 2019 after a complaint, in Blackville.
Across those inspections OSHA issued 71 citation items: 53 serious and 18 other-than-serious.
OSHA proposed $39,750 in penalties. After settlements and reviews the total is $24,788, down 38%.
Most often, OSHA cited 1910.107, spray painting and finishing (7 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Augusta Fiberglass Coatings Inc averages $1,550 over 1 cited inspection in that time.
1 inspection on this page followed a fatal incident.
South Carolina · latest 90 days of OSHA records
43employers cited
Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in South Carolina
Checking a subcontractor, a client or your own company? Watch Augusta Fiberglass Coatings Inc and get notified the morning OSHA posts a new citation for it.
Watch this companyOSHA records show Augusta Fiberglass Coatings Inc at 2 sites in 2 states. Together they've had 13 inspections and $75,119 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
See plans86 Lake Cynthia Rd, Blackville, SC 29817 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
86 Lake Cynthia Road, Blackville, SC 29817 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting |
Serious | $1,000 | $1,000 | Oct 17, 2018 | Final |
| Citation 2, item 1 29 CFR 1910.25(b)(3) · Stairways |
Other-than-serious | $0 | $0 | Oct 17, 2018 | Final |
| Citation 2, item 2a 29 CFR 1910.95(d)(1) · Noise |
Other-than-serious | $550 | $550 | Oct 17, 2018 | Final |
| Citation 2, item 2b 29 CFR 1910.95(g)(1) · Noise |
Other-than-serious | $0 | $0 | Oct 17, 2018 | Final |
| Citation 2, item 2c 29 CFR 1910.95(k)(1) · Noise |
Other-than-serious | $0 | $0 | Oct 17, 2018 | Final |
| Citation 2, item 2d 29 CFR 1910.95(l)(1) · Noise |
Other-than-serious | $0 | $0 | Oct 17, 2018 | Final |
86 Lake Cynthia Road, Blackville, SC 29817 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
86 Lake Cynthia Rd, Blackville, SC 29817 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
86 Lake Cynthia Rd, Blackville, SC 29817 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
86 Lake Cynthia Rd, Blackville, SC 29817 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.36(d)(1) · Exit route design |
Serious | $1,000 | $500 | Sep 18, 2012 | Closed |
| Citation 1, item 2 29 CFR 1910.106(d)(4)(i) · Flammable liquids |
Serious | $1,375 | $688 | Sep 18, 2012 | Final |
| Citation 1, item 3 29 CFR 1910.106(d)(4)(iii) · Flammable liquids |
Serious | $1,375 | $688 | Sep 18, 2012 | Final |
| Citation 1, item 4 29 CFR 1910.107(c)(5) · Spray painting and finishing |
Serious | $825 | $412 | Sep 18, 2012 | Final |
| Citation 1, item 5 29 CFR 1910.107(m)(1) · Spray painting and finishing |
Serious | $1,375 | $688 | Sep 18, 2012 | Final |
| Citation 1, item 6 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $1,375 | $688 | Sep 18, 2012 | Closed |
| Citation 1, item 7 29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks |
Serious | $1,375 | $688 | Sep 18, 2012 | Closed |
| Citation 1, item 9 29 CFR 1910.213(c)(1) · Woodworking machinery |
Serious | $825 | $412 | Sep 18, 2012 | Closed |
| Citation 1, item 10 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $600 | $300 | Sep 18, 2012 | Closed |
| Citation 1, item 12 29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts |
Serious | $825 | $412 | Sep 18, 2012 | Final |
| Citation 1, item 14 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Serious | $825 | $412 | Sep 18, 2012 | Final |
| Citation 1, item 15 29 CFR 1910.219(i)(2) · Belts, pulleys and power-transmission parts |
Serious | $825 | $412 | Sep 18, 2012 | Final |
| Citation 1, item 17 29 CFR 1910.242(b) · Hand and power tools |
Serious | $600 | $300 | Sep 18, 2012 | Closed |
| Citation 1, item 18 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Serious | $600 | $300 | Sep 18, 2012 | Closed |
| Citation 1, item 23 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $1,000 | $500 | Sep 18, 2012 | Closed |
| Citation 1, item 24 29 CFR 1910.305(j)(2)(v) · Electrical wiring methods |
Serious | $1,375 | $688 | Sep 18, 2012 | Closed |
| Citation 1, item 26a 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $0 | $550 | Sep 18, 2012 | Final |
| Citation 1, item 26b 29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Sep 18, 2012 | Final |
| Citation 1, item 26c 29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Sep 18, 2012 | Final |
| Citation 1, item 27a 29 CFR 1910.242(a) · Hand and power tools |
Serious | $0 | $300 | Sep 18, 2012 | Final |
| Citation 1, item 27b 29 CFR 1910.304(g)(6)(vic)(1) · Grounding and circuit protection |
Serious | $0 | $0 | Sep 18, 2012 | Final |
| Citation 1, item 27c 29 CFR 1910.304(g)(6)(vic)(3) · Grounding and circuit protection |
Serious | $0 | $0 | Sep 18, 2012 | Final |
| Citation 1, item 27d 29 CFR 1910.304(g)(6)(vic)(5) · Grounding and circuit protection |
Serious | $0 | $0 | Sep 18, 2012 | Final |
| Citation 1, item 27e 29 CFR 1910.304(g)(6)(vic)(8) · Grounding and circuit protection |
Serious | $0 | $0 | Sep 18, 2012 | Final |
| Citation 1, item 27f 29 CFR 1910.334(a)(3)(i) · Using electrical equipment |
Serious | $0 | $0 | Sep 18, 2012 | Final |
| Citation 2, item 1 29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Sep 18, 2012 | Closed |
| Citation 2, item 2 29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Sep 18, 2012 | Closed |
| Citation 2, item 3 29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Sep 18, 2012 | Closed |
| Citation 2, item 4 29 CFR 1910.213(c)(2) · Woodworking machinery |
Other-than-serious | $0 | $0 | Sep 18, 2012 | Closed |
| Citation 2, item 5 29 CFR 1910.213(c)(3) · Woodworking machinery |
Other-than-serious | $0 | $0 | Sep 18, 2012 | Closed |
| Citation 2, item 6 29 CFR 1910.244(a)(2)(vi) · Other portable tools and equipment |
Other-than-serious | $0 | $0 | Sep 18, 2012 | Closed |
| Citation 2, item 7 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Sep 18, 2012 | Closed |
| Citation 2, item 8 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Sep 18, 2012 | Closed |
| Citation 2, item 9 29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Sep 18, 2012 | Closed |
| Citation 2, item 10 29 CFR 1910.334(a)(2)(i) · Using electrical equipment |
Other-than-serious | $0 | $0 | Sep 18, 2012 | Closed |
86 Lake Cynthia Rd, Blackville, SC 29817 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.146(c)(1) · Permit-required confined spaces |
Serious | $1,375 | $1,375 | Jun 8, 2012 | Closed |
| Citation 1, item 2 29 CFR 1910.146(c)(4) · Permit-required confined spaces |
Serious | $1,375 | $1,375 | Jun 8, 2012 | Closed |
| Citation 1, item 3 29 CFR 1910.146(d)(10) · Permit-required confined spaces |
Serious | $1,375 | $1,375 | Jun 8, 2012 | Closed |
| Citation 1, item 4 29 CFR 1910.146(g)(1) · Permit-required confined spaces |
Serious | $1,375 | $1,375 | Jun 8, 2012 | Closed |
| Citation 1, item 5 29 CFR 1910.36(d)(1) · Exit route design |
Serious | $1,000 | $1,000 | Jun 8, 2012 | Closed |
| Citation 1, item 6 29 CFR 1910.37(a)(3) · Exit routes |
Serious | $1,000 | $1,000 | Jun 8, 2012 | Closed |
| Citation 1, item 7 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $600 | $600 | Jun 8, 2012 | Closed |
| Citation 2, item 1 29 CFR 1910.134(k)(6) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 8, 2012 | Closed |
Hwy. 3 South, Blackville, SC 29817 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Hwy. 3 South, Blackville, SC 29817 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Hwy. 3 South, Blackville, SC 29817 · OSHA's record · Phone and website on Google Maps
Incident on Jan 13, 1996 (fatal): Employee killed in flash fire
Employee #1 had finished spraying a fiberglass tank bottom in a 40 ft by 40 ft b uilding. The spray operation involved a dual component spray setup using Qua Cor r resin (164 degrees Fahrenheit flashpoint) and Qua Corr 2001 catalyst (518 degr ees F flashpoint). A coworker saw Employee #1 resting on a toolbox approximately 20 ft from the sprayed tank, smoking a cigarette while waiting for another empl oyee to get scissors to trim the mold. The coworker had brought a can of acetone back to the building, and was just leaving when he heard a flash fire. The buil ding was consumed in flames. Employee #1's body was found under the molded tank by firemen and employees after the fire was extinguished. The cause of death was determined to be smoke inhalation and heat burns. The tin-covered, wood-framed building was not equipped with a sprinkler system.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 4 29 CFR 1910.107(e)(9) · Spray painting and finishing |
Serious | $600 | $240 | Mar 12, 1996 | Closed |
| Citation 1, item 5 29 CFR 1910.107(m)(1) · Spray painting and finishing |
Serious | $1,100 | $440 | Mar 12, 1996 | Closed |
| Citation 1, item 6 29 CFR 1910.213(b)(3) · Woodworking machinery |
Serious | $600 | $240 | Mar 12, 1996 | Closed |
| Citation 1, item 7 29 CFR 1910.213(c)(1) · Woodworking machinery |
Serious | $600 | $240 | Mar 12, 1996 | Closed |
| Citation 1, item 8 29 CFR 1910.213(h)(1) · Woodworking machinery |
Serious | $600 | $240 | Mar 12, 1996 | Closed |
| Citation 1, item 9 29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts |
Serious | $600 | $240 | Mar 12, 1996 | Closed |
| Citation 1, item 10 29 CFR 1910.307(b) · Hazardous (classified) locations |
Serious | $800 | $320 | Mar 12, 1996 | Closed |
| Citation 1, item 11a 29 CFR 1910.107(c)(5) · Spray painting and finishing |
Serious | $1,925 | $770 | Mar 12, 1996 | Closed |
| Citation 1, item 11b 29 CFR 1910.107(c)(6)(i) · Spray painting and finishing |
Serious | $0 | $0 | Mar 12, 1996 | Closed |
| Citation 1, item 11c 29 CFR 1910.107(c)(7) · Spray painting and finishing |
Serious | $0 | $0 | Mar 12, 1996 | Closed |
Hwy. 3 South, Blackville, SC 29817 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Hwy. 3 South, Blackville, SC 29817 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 10012 A |
Serious | $900 | $450 | Oct 10, 1991 | Closed |
| Citation 1, item 2 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $560 | $280 | Oct 10, 1991 | Closed |
| Citation 1, item 3 29 CFR 1910.29(a)(3)(vi) · Manually propelled mobile ladder stands and scaffolds (towers) |
Serious | $720 | $360 | Oct 10, 1991 | Closed |
| Citation 1, item 4 29 CFR 1910.29(a)(3)(vii) · Manually propelled mobile ladder stands and scaffolds (towers) |
Serious | $800 | $400 | Oct 10, 1991 | Closed |
| Citation 1, item 5 29 CFR 1910.29(a)(4)(ii) · Manually propelled mobile ladder stands and scaffolds (towers) |
Serious | $720 | $360 | Oct 10, 1991 | Closed |
| Citation 1, item 6 29 CFR 1910.132(a) · Personal protective equipment, general requirements |
Serious | $720 | $360 | Oct 10, 1991 | Closed |
| Citation 1, item 7 29 CFR 1910.133(a)(1) · Eye and face protection |
Serious | $480 | $240 | Oct 10, 1991 | Closed |
| Citation 1, item 8 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $480 | $240 | Oct 10, 1991 | Closed |
| Citation 1, item 9 29 CFR 1910.178(m)(12) · Forklifts and other powered industrial trucks |
Serious | $560 | $280 | Oct 10, 1991 | Closed |
| Citation 1, item 10 29 CFR 1910.1200(h) · Hazard communication |
Serious | $1,000 | $500 | Oct 10, 1991 | Closed |
| Citation 2, item 1 29 CFR 30006 |
Other-than-serious | $80 | $0 | Oct 10, 1991 | Closed |
| Citation 2, item 2 29 CFR 1910.29(a)(3)(vii) · Manually propelled mobile ladder stands and scaffolds (towers) |
Other-than-serious | $80 | $0 | Oct 10, 1991 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(4)(i)
(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra
29 CFR 1910.106(d)(4)(iii)
(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.
29 CFR 1910.107(c)(5)
(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.
Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.