Inspection 344524251 OPENED DEC 18, 2019Closed
477 Cold Springs Road, Douglas, WY 82633 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Azota Gas Processing Ltd has 2 OSHA inspections on record in Wyoming, the first in 2019.
OSHA's last visit started on Dec 18, 2019 after a complaint, in Douglas.
Across those inspections OSHA issued 22 citation items: 18 serious and 4 other-than-serious.
OSHA proposed $49,474 in penalties. After settlements and reviews the total is $38,166, down 23%.
Most often, OSHA cited 1926.1204, permit-required confined space program (8 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Azota Gas Processing Ltd averages $38,166 over 1 cited inspection in that time.
Wyoming · latest 90 days of OSHA records
30employers cited
Get notified the morning OSHA posts each new citation in Wyoming: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Wyoming
Checking a subcontractor, a client or your own company? Watch Azota Gas Processing Ltd and get notified the morning OSHA posts a new citation for it.
Watch this company477 Cold Springs Road, Douglas, WY 82633 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
477 Cold Springs Road, Douglas, WY 82633 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.51(g) · Sanitation |
Serious | $4,240 | $4,240 | Feb 12, 2020 | Final |
| Citation 1, item 2 29 CFR 1926.152(b)(1) · Flammable liquids |
Serious | $7,068 | $7,068 | Feb 12, 2020 | Final |
| Citation 1, item 3 29 CFR 1910.178(m)(5)(i) · Forklifts and other powered industrial trucks |
Serious | $5,654 | $5,654 | Feb 12, 2020 | Final |
| Citation 1, item 4 29 CFR 1926.350(a)(9) · Gas welding and cutting |
Serious | $7,068 | $7,068 | Feb 12, 2020 | Final |
| Citation 1, item 5 29 CFR 1926.351(e) · Arc welding and cutting |
Other-than-serious | $4,240 | $0 | Feb 12, 2020 | Final |
| Citation 1, item 6 29 CFR 1926.352(c) · Fire prevention |
Other-than-serious | $7,068 | $0 | Feb 12, 2020 | Final |
| Citation 1, item 7 29 CFR 1926.1153(d)(2)(i) · Silica dust in construction |
Serious | $7,068 | $7,068 | Feb 12, 2020 | Final |
| Citation 1, item 8a 29 CFR 1926.1203(a) · Confined Spaces in Construction: general requirements |
Serious | $7,068 | $7,068 | Feb 12, 2020 | Final |
| Citation 1, item 8b 29 CFR 1926.1203(b)(1) · Confined Spaces in Construction: general requirements |
Serious | $0 | $0 | Feb 12, 2020 | Final |
| Citation 1, item 8c 29 CFR 1926.1203(d) · Confined Spaces in Construction: general requirements |
Serious | $0 | $0 | Feb 12, 2020 | Final |
| Citation 1, item 8d 29 CFR 1926.1203(e)(2)(iii) · Confined Spaces in Construction: general requirements |
Serious | $0 | $0 | Feb 12, 2020 | Final |
| Citation 1, item 8e 29 CFR 1926.1203(e)(2)(ix) · Confined Spaces in Construction: general requirements |
Serious | $0 | $0 | Feb 12, 2020 | Final |
| Citation 1, item 8f 29 CFR 1926.1204(b) · Permit-required confined space program |
Serious | $0 | $0 | Feb 12, 2020 | Final |
| Citation 1, item 8g 29 CFR 1926.1204(c)(3) · Permit-required confined space program |
Serious | $0 | $0 | Feb 12, 2020 | Final |
| Citation 1, item 8h 29 CFR 1926.1204(d)(1) · Permit-required confined space program |
Serious | $0 | $0 | Feb 12, 2020 | Final |
| Citation 1, item 8i 29 CFR 1926.1204(d)(8) · Permit-required confined space program |
Serious | $0 | $0 | Feb 12, 2020 | Final |
| Citation 1, item 8j 29 CFR 1926.1204(e)(1) · Permit-required confined space program |
Serious | $0 | $0 | Feb 12, 2020 | Final |
| Citation 1, item 8k 29 CFR 1926.1204(f) · Permit-required confined space program |
Serious | $0 | $0 | Feb 12, 2020 | Final |
| Citation 1, item 8l 29 CFR 1926.1204(h) · Permit-required confined space program |
Serious | $0 | $0 | Feb 12, 2020 | Final |
| Citation 1, item 8m 29 CFR 1926.1204(i) · Permit-required confined space program |
Serious | $0 | $0 | Feb 12, 2020 | Final |
| Citation 2, item 1 29 CFR 1910.134(c)(2)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | Feb 12, 2020 | Final |
| Citation 2, item 2 29 CFR 1926.453(b)(2)(iv) · Aerial lifts |
Other-than-serious | $0 | $0 | Feb 12, 2020 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(c)(2)(i)
(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and
29 CFR 1910.178(m)(5)(i)
(5)(i) When a powered industrial truck is left unattended, load engaging means shall be fully lowered, controls shall be neutralized, power shall be shut off, and brakes set. Wheels shall be blocked if the truck is parked on an incline.
29 CFR 1926.1153(d)(2)(i)
(2) Exposure assessment—(i) General. The employer shall assess the exposure of each employee who is or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section.
Alert subscribers get notified of each newly cited employer in Wyoming the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.