Aztec Steel Inc.: OSHA inspections and violations

Boston, Massachusetts · Other Foundation, Structure, and Building Exterior Contractors · NAICS 238190

17inspections
25citation items
$32,822current penalties
Oct 8, 2021last inspection

OSHA has inspected Aztec Steel Inc. 17 times in Massachusetts since 1988.

The latest one began on Oct 8, 2021 on a referral, in Boston.

Those inspections ended with 25 citation items: 22 serious and 3 other-than-serious.

Penalties were first proposed at $54,433 and now stand at $32,822, 40% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 7 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Aztec Steel Inc. averages $18,272 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

Aztec Steel Inc.: OSHA citation items per year, 1988 to 2021
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

256employers cited

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Aztec Steel Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345598601 OPENED OCT 8, 2021Closed

Referral · Partial · Safety · 35 employees at the site · Closed Nov 7, 2022

115 Federal Street, Boston, MA 02110 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$9,136$9,136Mar 29, 2022Final
Citation 1, item 2
29 CFR 1926.501(a)(2) · Fall protection in construction
Serious$9,136$9,136Mar 29, 2022Final

Inspection 344669288 OPENED MAR 3, 2020Closed

Unprogrammed other · Complete · Safety · 23 employees at the site · Closed May 13, 2020

111 Federal Street 115 Winthrop Square, Boston, MA 02119 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315144329 OPENED OCT 13, 2011Closed

Planned · Partial · Safety · 30 employees at the site · Closed Dec 6, 2011

300 Longwood Avenue, Boston, MA 02115 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313797029 OPENED JAN 21, 2010Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed Jan 25, 2010

870 River Street, Hyde Park, MA 02136 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312104144 OPENED APR 1, 2009Closed

Unprogrammed related · Complete · Safety · 11 employees at the site · Closed Jun 17, 2009

Russia Wharf, Boston, MA 02210 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$600$300May 20, 2009Closed
Citation 1, item 1b
29 CFR 1926.501(b)(4)(iii) · Fall protection in construction
Serious$0$0May 20, 2009Closed

Inspection 309468403 OPENED NOV 28, 2005Closed

Unprogrammed other · Complete · Safety · 30 employees at the site · Closed Apr 3, 2007

140 Commonwealth Avenue, Chestnut Hill, MA 02467 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.34(c) · Means of egress
Serious$1,200$750May 25, 2006Final
Citation 1, item 2
29 CFR 1926.106(a) · Working over or near water
Serious$3,000$750May 25, 2006Final
Citation 1, item 3
29 CFR 1926.106(d) · Working over or near water
Serious$3,000$750May 25, 2006Final
Citation 1, item 4
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,000$750May 25, 2006Final
Citation 1, item 5
29 CFR 1926.502(b)(4) · Fall protection systems
Serious$3,000$750May 25, 2006Final
Citation 1, item 6
29 CFR 1926.802(b) · Cofferdams
Serious$1,500$750May 25, 2006Final
Citation 1, item 7
29 CFR 1926.802(c) · Cofferdams
Serious$1,500$750May 25, 2006Final
Citation 2, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$6,000$750May 25, 2006Final

Inspection 308103464 OPENED NOV 4, 2004Closed

Unprogrammed related · Complete · Safety · 9 employees at the site · Closed May 20, 2005

500 Atlantic Avenue, Boston, MA 02210 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(b)(1) · Fall protection systems
Other-than-serious$1,500$750Apr 22, 2005Closed
Citation 1, item 2
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$1,200$600Apr 22, 2005Closed

Inspection 306098906 OPENED OCT 2, 2003Closed

Unprogrammed related · Partial · Safety · 50 employees at the site · Closed Jan 16, 2004

140 Commonwealth Avenue, Chestnut Hill, MA 02467 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(a)(1) · Fall protection
Serious$3,000$3,000Dec 29, 2003Closed
9 older inspections

Inspection 305543852 OPENED SEP 27, 2002Closed

Unprogrammed related · Complete · Safety · 17 employees at the site · Closed Sep 30, 2002

1 Charles Street South, Boston, MA 02111 · Remediation Services · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305542201 OPENED JUL 12, 2002Closed

Unprogrammed related · Partial · Safety · 77 employees at the site · Closed Oct 2, 2002

283 Longwood Avenue, Boston, MA 02115 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.250(b)(9) · General requirements for storage
Serious$446$223Sep 13, 2002Closed

Inspection 302923495 OPENED SEP 11, 2000Closed

Unprogrammed related · Complete · Safety · 6 employees at the site · Closed Nov 16, 2000

Mbta Silver Line, Sleeper Street, South Boston, MA 02127 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302920020 OPENED MAR 6, 2000Closed

Unprogrammed related · Complete · Safety · 24 employees at the site · Closed Sep 11, 2000

1 Avery Street, Boston, MA 02111 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$875$438Aug 25, 2000Closed

Inspection 302060520 OPENED JAN 19, 1999Closed

Unprogrammed other · Complete · Safety · 21 employees at the site · Closed Feb 4, 1999

C07d2, Central Artery, Boston, MA 02128 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302059761 OPENED DEC 1, 1998Closed

Unprogrammed related · Complete · Safety · 8 employees at the site · Closed Feb 12, 1999

1979 Bay Street, Fall River, MA 02722 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Other-than-serious$3,000$1,500Dec 16, 1998Closed

Inspection 300344843 OPENED NOV 19, 1997Closed

Unprogrammed other · Complete · Safety · 30 employees at the site · Closed Mar 16, 1998

C07d2, Central Artery, Boston, MA 02128 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,400$700Dec 8, 1997Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$675$338Dec 8, 1997Closed

Inspection 108931403 OPENED JUN 22, 1992Closed

Unprogrammed related · Complete · Safety · 2 employees at the site · Closed Oct 27, 1992

700 Albany Street, Boston, MA 02118 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.250(a)(3) · General requirements for storage
Serious$375$188Oct 9, 1992Closed
Citation 1, item 2
29 CFR 1926.500(b)(2) · Scope, application, and definitions applicable to this subpart
Serious$375$188Oct 9, 1992Closed
Citation 1, item 3
29 CFR 1926.500(b)(7) · Scope, application, and definitions applicable to this subpart
Serious$375$188Oct 9, 1992Closed
Citation 2, item 1
29 CFR 1926.500(f)(1)(vib) · Scope, application, and definitions applicable to this subpart
Other-than-serious$0$0Oct 9, 1992Closed

Inspection 103423901 OPENED DEC 1, 1988Closed

Unprogrammed related · Complete · Safety · 7 employees at the site · Closed Feb 14, 1989

389 Binney Street, Cambridge, MA 02142 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Serious$140$140Jan 19, 1989Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Oct 24, 2016, Boston: Hospitalization · soreness, pain, hurt-nonspecified injury · back, including spine, spinal cord, unspecified

An employee was struck in the back by a piece of rebar resulting in hospitalization.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.106 · Working over or near water

29 CFR 1926.106(a)

(a) Employees working over or near water, where the danger of drowning exists, shall be provided with U.S. Coast Guard-approved life jacket or buoyant work vests.

29 CFR 1926.106(d)

(d) At least one lifesaving skiff shall be immediately available at locations where employees are working over or adjacent to water.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.250 · General requirements for storage

29 CFR 1926.34 · Means of egress

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.760 · Fall protection

29 CFR 1926.802 · Cofferdams

OSH Act Section 5 · General Duty Clause

Other other foundation, structure, and building exterior contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.