OSHA SearchOSHA records by employer

Aztech Plastering, LLC: OSHA inspections and violations

Las Vegas, Nevada · Drywall and Insulation Contractors · NAICS 238310

37inspections
89citation items
$47,911current penalties
Jan 8, 2026last inspection

Since 1993, OSHA inspectors have visited Aztech Plastering, LLC in Nevada 37 times.

The most recent inspection opened on Jan 8, 2026 as a planned inspection, in Las Vegas.

In all, OSHA issued 89 citation items: 58 serious, 8 repeat and 23 other-than-serious.

The proposed penalties came to $66,363; today they stand at $47,911, 28% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 58 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Aztech Plastering, LLC averages $1,996 across 14 cited inspections.

Aztech Plastering, LLC also files yearly injury logs with OSHA, summarized below.

The Wage and Hour Division has 2 cases on it since 2015, with $4,737 in back wages owed to workers.

Aztech Plastering, LLC: OSHA citation items per year, 1993 to 2026
Citation items per year, by inspection date.

Want to know if OSHA cites Aztech Plastering, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348680265 OPENED JAN 8, 2026Closed

Planned · Complete · Safety · 29 employees at the site · Closed Jul 28, 2026

1207 South 3rd Street, Las Vegas, NV 89104 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(iii)(c) · Ground-fault protection on job sites
Other-than-serious$0$0Jun 26, 2026Final

Inspection 348707886 OPENED JAN 8, 2026Closed

Planned · Complete · Health · 29 employees at the site · Closed Sep 14, 2026

1207 South 3rd Street, Las Vegas, NV 89104 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR LCB FILE NO. R069-20 (APPROVED AP
Other-than-serious$7,597$6,837Jun 26, 2026Final
Citation 1, item 2
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$711$640Jun 26, 2026Final

Inspection 348139908 OPENED MAR 26, 2025Closed

Planned · Complete · Safety · 42 employees at the site · Closed Aug 12, 2025

255 Promenade Place, Las Vegas, NV 89106 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346338460 OPENED NOV 10, 2022Closed

Unprogrammed related · Complete · Safety · 11 employees at the site · Closed Apr 6, 2023

100 East Warm Springs Road, Henderson, NV 89011 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345457667 OPENED AUG 4, 2021Closed

Planned · Complete · Safety · 11 employees at the site · Closed Oct 25, 2021

4400 Nexus Way, North Las Vegas, NV 89081 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345418974 OPENED JUL 6, 2021Closed

Planned · Complete · Safety · 12 employees at the site · Closed Oct 6, 2021

1091 Fielders Street, Henderson, NV 89011 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344568951 OPENED JAN 21, 2020Closed

Planned · Complete · Safety · 9 employees at the site · Closed Mar 12, 2020

7850 Giles Street, Las Vegas, NV 89113 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344274865 OPENED AUG 30, 2019Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Sep 5, 2019

11255 West Torino Avenue, Las Vegas, NV 89161 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

29 older inspections

Inspection 344142658 OPENED JUN 14, 2019Closed

Planned · Complete · Safety · 77 employees at the site · Closed Jul 15, 2019

655 East Dale Avenue, Henderson, NV 89044 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343818456 OPENED FEB 25, 2019Closed

Follow-up · Partial · Safety · 1 employee at the site · Closed Feb 25, 2019

11255 West Torino Avenue, Las Vegas, NV 89161 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343378352 OPENED JUL 16, 2018Closed

Planned · Complete · Safety · 17 employees at the site · Closed Sep 6, 2018

4259 South Maryland Parkway, Las Vegas, NV 89119 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343193348 OPENED MAY 23, 2018Closed

Planned · Complete · Safety · 120 employees at the site · Closed Feb 25, 2019

610 Crossbridge Drive, Las Vegas, NV 89138 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$4,500$4,500Aug 23, 2018Final

Inspection 342976289 OPENED FEB 26, 2018Closed

Planned · Complete · Safety · 10 employees at the site · Closed May 31, 2018

9450 West Hacienda Avenue, Las Vegas, NV 89148 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(8) · Scaffolds, general requirements
Other-than-serious$655$655Apr 19, 2018Final

Inspection 342625845 OPENED SEP 6, 2017Closed

Unprogrammed related · Complete · Safety · 5 employees at the site · Closed Jan 22, 2018

1501 West Lake Mead, Las Vegas, NV 89106 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$3,825$2,869Oct 31, 2017Final
Citation 2, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Other-than-serious$0$0Oct 31, 2017Final

Inspection 342509940 OPENED JUL 24, 2017Closed

Unprogrammed related · Partial · Safety · 120 employees at the site · Closed Nov 1, 2017

8060 West Tropical Parkway, Las Vegas, NV 89103 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Repeat$100$100Sep 27, 2017Final

Inspection 342305661 OPENED MAY 1, 2017Closed

Planned · Complete · Safety · 8 employees at the site · Closed Apr 30, 2018

9880 West Flamingo Road, Las Vegas, NV 89147 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Repeat$6,400$3,840Sep 15, 2017Final
Citation 2, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,200$1,320Sep 15, 2017Final

Inspection 342254539 OPENED APR 12, 2017Closed

Planned · Complete · Safety · 8 employees at the site · Closed Aug 17, 2017

7740 South Las Vegas Blvd., Las Vegas, NV 89123 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Other-than-serious$0$0Jun 29, 2017Final
Citation 1, item 2
29 CFR 1926.451(h)(2)(i) · Scaffolds, general requirements
Other-than-serious$0$0Jun 29, 2017Final

Inspection 342256823 OPENED APR 12, 2017Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jun 10, 2017

1581 Mount Mariah Drive, Las Vegas, NV 89106 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(4) · Ladders in construction
Other-than-serious$0$0May 16, 2017Final

Inspection 342080348 OPENED FEB 1, 2017Closed

Planned · Complete · Safety · 7 employees at the site · Closed May 2, 2017

10445 Spencer Street, Las Vegas, NV 89183 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Mar 10, 2017Final
Citation 2, item 2
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Mar 10, 2017Final

Inspection 342149978 OPENED JAN 24, 2017Closed

Planned · Complete · Safety · 131 employees at the site · Closed Nov 21, 2017

7975 Blue Diamond Road, Las Vegas, NV 89178 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$3,000$3,000May 5, 2017Final
Citation 2, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0May 5, 2017Final
Citation 2, item 2
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0May 5, 2017Final
Citation 2, item 3
29 CFR 1910.134(k)(1) · Respiratory protection
Other-than-serious$0$0May 5, 2017Final

Inspection 341284198 OPENED FEB 25, 2016Closed

Unprogrammed other · Complete · Safety · 8 employees at the site · Closed May 31, 2016

7202 South Jones Blvd, Las Vegas, NV 89118 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Serious$1,000$1,000Apr 13, 2016Final

Inspection 340624246 OPENED MAY 12, 2015Closed

Unprogrammed other · Complete · Safety · 8 employees at the site · Closed Sep 3, 2015

5739 East Russel Road, Henderson, NV 89014 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(8) · Scaffolds, general requirements
Serious$2,400$1,680Jun 29, 2015Final
Citation 2, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Other-than-serious$0$0Jun 29, 2015Final

Inspection 340219336 OPENED JAN 21, 2015Closed

Accident · Partial · Safety · 20 employees at the site · Closed Apr 16, 2015

2151 Village Walk Drive, Henderson, NV 89052 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jan 19, 2015: An employee working from scaffold falls, sustains leg fractu

At 3:00 p.m. on January 19, 2015, Employee #1, employed by a plastering company, was working at a multifamily residential building construction project. He was standing on a scaffold and applying plaster by hand to pop-outs. A plank on the scaffold platform broke, and Employee #1 fell to the ground, a fall height of 5 feet. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for a compound fracture of his right leg below the knee.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$1,500$1,500Feb 20, 2015Final

Inspection 340138999 OPENED DEC 9, 2014Closed

Unprogrammed other · Complete · Safety · 21 employees at the site · Closed Mar 24, 2015

875 South Grand Central Parkway, Las Vegas, NV 89106 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.40(a) · Giving injury records to OSHA
Other-than-serious$150$150Jan 29, 2015Final

Inspection 317373470 OPENED APR 18, 2014Closed

Referral · Partial · Safety · 17 employees at the site · Closed May 15, 2014

594 North Stephanie Street, Henderson, NV 89014 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316838200 OPENED NOV 14, 2012Closed

Referral · Partial · Safety · 2 employees at the site · Closed Jan 7, 2013

232 North Jones Avneue, Las Vegas, NV 89107 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314888280 OPENED DEC 3, 2010Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jun 17, 2011

7400 Las Vegas Blvd., South, Las Vegas, NV 89123 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.32(a)(1) · Yearly injury summary
Other-than-serious$700$700Mar 8, 2011Closed

Inspection 312278757 OPENED SEP 8, 2008Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Sep 17, 2008

Eastern Avenue & Sunset Road (hampton Inn), Las Vegas, NV 89119 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310431473 OPENED MAR 20, 2007Closed

Unprogrammed related · Partial · Safety · 8 employees at the site · Closed May 29, 2007

5905 West Charleston Blvd., Las Vegas, NV 89146 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$875$875Apr 2, 2007Closed
Citation 1, item 2
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$625$625Apr 2, 2007Closed

Inspection 310428578 OPENED JAN 4, 2007Closed

Planned · Complete · Safety · 18 employees at the site · Closed Apr 17, 2007

6584 Decatur Blvd, Las Vegas, NV 89084 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Repeat$10,000$6,000Feb 13, 2007Closed
Citation 1, item 1b
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Repeat$0$0Feb 13, 2007Closed
Citation 1, item 1c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Repeat$0$0Feb 13, 2007Closed
Citation 2, item 1a
29 CFR 1926.451(b)(3)(ii) · Scaffolds, general requirements
Serious$625$375Feb 13, 2007Closed
Citation 2, item 1b
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Serious$0$0Feb 13, 2007Closed
Citation 2, item 1c
29 CFR 1926.451(b)(8) · Scaffolds, general requirements
Serious$0$0Feb 13, 2007Closed
Citation 2, item 1d
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Feb 13, 2007Closed
Citation 2, item 1e
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Feb 13, 2007Closed
Citation 2, item 2a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$625$375Feb 13, 2007Closed
Citation 2, item 2b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Feb 13, 2007Closed
Citation 2, item 2c
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Feb 13, 2007Closed
Citation 2, item 2d
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Feb 13, 2007Closed
Citation 3, item 1a
29 CFR 1904.32(a)(1) · Yearly injury summary
Other-than-serious$0$0Jan 30, 2007Closed
Citation 3, item 1b
29 CFR 1904.32(b)(2)(i) · Yearly injury summary
Other-than-serious$0$0Jan 30, 2007Closed
Citation 3, item 1c
29 CFR 1904.32(b)(2)(ii) · Yearly injury summary
Other-than-serious$0$0Jan 30, 2007Closed

Inspection 309409746 OPENED DEC 29, 2005Closed

Planned · Complete · Safety · 9 employees at the site · Closed May 8, 2006

1489 Foothills Village Drive, Henderson, NV 89012 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.307(b)(1) · Mechanical power-transmission apparatus
Serious$2,000$1,200Feb 8, 2006Closed
Citation 1, item 1b
29 CFR 1926.307(e)(3)(i) · Mechanical power-transmission apparatus
Serious$0$0Feb 8, 2006Closed
Citation 1, item 2a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,000$1,200Feb 8, 2006Closed
Citation 1, item 2b
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$0$0Feb 8, 2006Closed
Citation 1, item 2c
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$0$0Feb 8, 2006Closed
Citation 1, item 2d
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Feb 8, 2006Closed
Citation 1, item 2e
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$0$0Feb 8, 2006Closed
Citation 1, item 2f
29 CFR 1926.452(c)(3) · Rules for each type of scaffold
Serious$0$0Feb 8, 2006Closed
Citation 2, item 1a
29 CFR 1904.32(b)(1) · Yearly injury summary
Other-than-serious$0$0Jan 18, 2006Closed
Citation 2, item 1b
29 CFR 1904.32(b)(2)(ii) · Yearly injury summary
Other-than-serious$0$0Jan 18, 2006Closed
Citation 2, item 2
29 CFR 1926.307(p)(1) · Mechanical power-transmission apparatus
Other-than-serious$0$0Jan 18, 2006Closed

Inspection 307585612 OPENED MAY 14, 2004Closed

Planned · Complete · Safety · 22 employees at the site · Closed May 27, 2004

7830 Las Vegas Blvd. South, Las Vegas, NV 89123 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307581603 OPENED MAR 10, 2004Closed

Unprogrammed related · Partial · Safety · 45 employees at the site · Closed May 11, 2004

7900 West Sahara Avenue, Las Vegas, NV 89117 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$625$625Apr 15, 2004Closed
Citation 1, item 1b
29 CFR 1926.451(g)(4)(xv) · Scaffolds, general requirements
Serious$0$0Apr 15, 2004Closed
Citation 1, item 1c
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$0$0Apr 15, 2004Closed

Inspection 305001984 OPENED JAN 3, 2002Closed

Referral · Partial · Safety · 2 employees at the site · Closed Aug 12, 2002

983 Auto Show Drive, Henderson, NV 89104 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Repeat$2,000$1,200Mar 11, 2002Closed
Citation 1, item 1b
29 CFR 1926.451(b)(10) · Scaffolds, general requirements
Repeat$0$0Mar 11, 2002Closed
Citation 1, item 1c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Repeat$0$0Mar 11, 2002Closed
Citation 2, item 1a
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$1,000$600Mar 11, 2002Closed
Citation 2, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Mar 11, 2002Closed
Citation 2, item 1c
29 CFR 1926.451(g)(4)(ii) · Scaffolds, general requirements
Serious$0$0Mar 11, 2002Closed
Citation 2, item 1d
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$0$0Mar 11, 2002Closed
Citation 2, item 1e
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$0$0Mar 11, 2002Closed

Inspection 304644842 OPENED JUL 24, 2001Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jun 24, 2002

Mission Dr/horizon Ridge (palm Hills), Henderson, NV 89015 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,000$1,500Sep 17, 2001Closed
Citation 1, item 1b
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$0$0Sep 17, 2001Closed
Citation 1, item 1c
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Sep 17, 2001Closed
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$3,000$1,500Sep 17, 2001Closed
Citation 1, item 2b
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0Sep 17, 2001Closed
Citation 1, item 2c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Sep 17, 2001Closed
Citation 1, item 2d
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Sep 17, 2001Closed
Citation 1, item 2e
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$0$0Sep 17, 2001Closed
Citation 1, item 2f
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Sep 17, 2001Closed

Inspection 302533393 OPENED DEC 14, 1999Closed

Unprogrammed related · Partial · Safety · 17 employees at the site · Closed Aug 31, 2000

6560 Surrey Street, Las Vegas, NV 89119 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$900Feb 18, 2000Closed
Citation 1, item 1b
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$0$0Feb 18, 2000Closed
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$300$180Feb 18, 2000Closed
Citation 1, item 2b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Feb 18, 2000Closed
Citation 1, item 2c
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Feb 18, 2000Closed
Citation 1, item 3a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,500$900Feb 18, 2000Closed
Citation 1, item 3b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Feb 18, 2000Closed
Citation 1, item 3c
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$0$0Feb 18, 2000Closed
Citation 1, item 4
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$375$225Feb 18, 2000Closed
Citation 1, item 5
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$525$315Feb 18, 2000Closed
Citation 2, item 1 Other-than-serious$0$0Jan 7, 2000Closed

Inspection 114575244 OPENED APR 26, 1993Closed

Referral · Partial · Safety · 8 employees at the site · Closed Feb 7, 1994

1518 East Fremont Avenue, Las Vegas, NV 89101 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(8) · Scaffolds, general requirements
Serious$1,050$525May 24, 1993Final
Citation 1, item 1b
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$0$0May 24, 1993Final
Citation 1, item 1c
29 CFR 1926.451(d)(3) · Scaffolds, general requirements
Serious$0$0May 24, 1993Final
Citation 1, item 1d
29 CFR 1926.451(d)(7) · Scaffolds, general requirements
Serious$0$0May 24, 1993Final
Citation 1, item 1e
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$0$0May 24, 1993Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Las Vegas site logged 8 recordable injuries or illnesses among about 96 workers: 15.6 per 100 full-time workers, against a median of 2.8 for its industry. Those cases cost 11 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Main Office - 01
Las Vegas · 2025
96 8215.62.8

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Nov 29, 2017 to Dec 10, 2019
Las Vegas
1312$2,542$0
Nov 27, 2014 to Nov 28, 2017
Las Vegas
22$2,195$0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(a)(1)

(1) Review the OSHA 300 Log to verify that the entries are complete and accurate, and correct any deficiencies identified;

29 CFR 1904.32(b)(1)

(b) Implementation—(1) How extensively do I have to review the OSHA 300 Log entries at the end of the year? You must review the entries as extensively as necessary to make sure that they are complete and correct.

29 CFR 1904.32(b)(2)(i)

(i) Total the columns on the OSHA 300 Log (if you had no recordable cases, enter zeros for each column total); and

29 CFR 1904.40 · Giving injury records to OSHA

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.307 · Mechanical power-transmission apparatus

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 6180.3830

Other drywall and insulation contractors employers in Nevada

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.