Badger Equipment Company: OSHA inspections and violations
Winona, Minnesota · Construction Machinery Manufacturing · NAICS 333120
11inspections
35citation items
$14,228current penalties
May 25, 2021last inspection
Badger Equipment Company has 11 OSHA inspections on record in Minnesota, the first in 1996.
OSHA's last visit started on May 25, 2021 as a planned inspection, in Winona.
Across those inspections OSHA issued 35 citation items: 28 serious and 7 other-than-serious.
OSHA proposed $24,225 in penalties. After settlements and reviews the total is $14,228, down 41%.
Most often, OSHA cited 1910.107, spray painting and finishing (5 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Badger Equipment Company averages $656 over 2 cited inspections in that time.
Badger Equipment Company also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Minnesota · latest 90 days of OSHA records
371employers cited
Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2020, the Winona site logged 9 recordable injuries or illnesses among about 24 workers: 36.2 per 100 full-time workers, against a median of 2.7 for its industry. Those cases cost 69 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Badger Equipment Co
Winona · 2020
24
9
4
36.2
2.7
Badger Equipment Co.
Winona · 2019
27
3
0
12.3
2.7
Included with any plan: 2 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
(b) Spray booths—(1) Construction. Spray booths shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet.
29 CFR 1910.107(e)(2)
(2) Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner.
29 CFR 1910.110 · Storage and handling of liquefied petroleum gases
Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.