OSHA SearchOSHA records by employer

Bandera Utility Contractors, LLC: OSHA inspections and violations

Frisco, Texas · Water and Sewer Line and Related Structures Construction · NAICS 237110

3inspections
9citation items
$176,992current penalties
Jul 30, 2024last inspection

Since 2012, OSHA inspectors have visited Bandera Utility Contractors, LLC in Texas 3 times.

The most recent inspection opened on Jul 30, 2024 after a complaint, in Fort Worth.

In all, OSHA issued 9 citation items: 8 serious and 1 other-than-serious.

The proposed penalties came to $251,220; today they stand at $176,992, 30% less.

The rule cited most here is 1926.1053 (ladders in construction), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Bandera Utility Contractors, LLC averages $86,046 across 2 cited inspections.

1 inspection on this page followed a fatal incident.

Bandera Utility Contractors, LLC: OSHA citation items per year, 2012 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Bandera Utility Contractors, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347653461 OPENED JUL 30, 2024Closed

Complaint · Partial · Safety · 20 employees at the site · Closed Jan 28, 2025

1900 Blue Mound Road West Marlowe Wellington Hybrid, Fort Worth, TX 76131 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$13,690$8,214Dec 23, 2024Final
Citation 2, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$31,939$31,939Dec 23, 2024Final
Citation 2, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$31,939$31,939Dec 23, 2024Final

Inspection 346042393 OPENED JUN 24, 2022Closed

Fatality or catastrophe · Partial · Safety · 130 employees at the site · Closed May 14, 2024

4643 Fm 543, Mckinney, TX 75071 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Jun 24, 2022 (fatal): Employee is killed while repairing pipeline after trench col

At 9:00 a.m. on June 24, 2022, an employee was working in a trench repairing a new sewer line when the trench collapsed. The employee was asphyixated and died on the scene.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(k)(1) · Excavations
Serious$13,052$13,052Dec 20, 2022Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$13,052$13,052Dec 20, 2022Final
Citation 1, item 3
29 CFR 1926.1053(b)(15) · Ladders in construction
Serious$9,324$13,052Dec 20, 2022Final
Citation 2, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$130,524$60,844Dec 20, 2022Final

Inspection 337609838 OPENED NOV 28, 2012Closed

Planned · Partial · Safety · 38 employees at the site · Closed Feb 1, 2013

5275 Town & Country Boulevard Block A Lot 3r, Frisco, TX 75034 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(6) · Ladders in construction
Other-than-serious$2,800$0Dec 26, 2012Final
Citation 1, item 2
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$4,900$4,900Dec 26, 2012Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(15)

(15) Ladders shall be inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.