OSHA SearchOSHA records by employer

Barefoot Spas LLC: OSHA inspections and violations

Richmond, Virginia · Plastics Plumbing Fixture Manufacturing · NAICS 326191

2inspections
7citation items
$2,828current penalties
Dec 10, 2019last inspection

Since 2019, OSHA inspectors have visited Barefoot Spas LLC in Virginia 2 times.

The most recent inspection opened on Dec 10, 2019 as a planned inspection, in Richmond.

In all, OSHA issued 7 citation items: 3 serious and 4 other-than-serious.

The proposed penalties came to $4,040; today they stand at $2,828, 30% less.

The rule cited most here is 1910.215 (grinders and abrasive wheels), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Barefoot Spas LLC averages $1,414 across 2 cited inspections.

Barefoot Spas LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Barefoot Spas LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344499660 OPENED DEC 10, 2019Closed

Planned · Complete · Health · 80 employees at the site · Closed Mar 11, 2020

8401 Fort Darling Road North Chesterfield, Richmond, VA 23237 · Plastics Plumbing Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Feb 11, 2020Final

Inspection 344253760 OPENED AUG 22, 2019Closed

Planned · Complete · Safety · 50 employees at the site · Closed Nov 1, 2019

8401 Fort Darling Road North Chesterfield, Richmond, VA 23237 · Plastics Plumbing Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$2,020$1,414Oct 21, 2019Final
Citation 1, item 1b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Oct 21, 2019Final
Citation 1, item 2
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$2,020$1,414Oct 21, 2019Final
Citation 2, item 1
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Oct 21, 2019Final
Citation 2, item 2
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Oct 21, 2019Final
Citation 2, item 3
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 21, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(c)(4)

(4) The employer shall assure that portable fire extinguishers are maintained in a fully charged and operable condition and kept in their designated places at all times except during use.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(p)(1)

(p) Operation of the truck. (1) If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

Other plastics plumbing fixture manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.