OSHA SearchOSHA records by employer

Bayou Trailers & Manufacturing, LLC: OSHA inspections and violations

Waveland, Mississippi · Truck Trailer Manufacturing · NAICS 336212

2inspections
11citation items
$17,928current penalties
Oct 25, 2017last inspection

OSHA has inspected Bayou Trailers & Manufacturing, LLC 2 times in Mississippi since 2017.

The latest one began on Oct 25, 2017 to follow up on an earlier case, in Waveland.

Those inspections ended with 11 citation items: 10 serious and 1 other-than-serious.

Penalties were first proposed at $17,928 and still stand at $17,928.

Spray painting and finishing comes up most often in these citations: 5 items under 1910.107.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Bayou Trailers & Manufacturing, LLC averages $17,928 (1 cited inspection).

Bayou Trailers & Manufacturing, LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Mississippi · latest 90 days of OSHA records

24employers cited

Get notified the morning OSHA posts each new citation in Mississippi: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Mississippi

Checking a subcontractor, a client or your own company? Watch Bayou Trailers & Manufacturing, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342729944 OPENED OCT 25, 2017Closed

Follow-up · Partial · Safety · 8 employees at the site · Closed Oct 27, 2017

463 Hwy 90, Waveland, MS 39576 · Truck Trailer Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342578267 OPENED AUG 23, 2017Closed

Monitoring · Partial · Safety · 8 employees at the site · Closed Jun 25, 2020

463 Hwy 90, Waveland, MS 39576 · Truck Trailer Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(c)(5) · Spray painting and finishing
Serious$2,173$2,173Sep 22, 2017Final
Citation 1, item 1b
29 CFR 1910.107(d)(5) · Spray painting and finishing
Serious$0$0Sep 22, 2017Final
Citation 1, item 2
29 CFR 1910.107(e)(2) · Spray painting and finishing
Serious$2,173$2,173Sep 22, 2017Final
Citation 1, item 3
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$2,173$2,173Sep 22, 2017Final
Citation 1, item 4
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$2,173$2,173Sep 22, 2017Final
Citation 1, item 5
29 CFR 1910.212(a)(5) · Machine guarding
Serious$2,173$2,173Sep 22, 2017Final
Citation 1, item 6
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$2,173$2,173Sep 22, 2017Final
Citation 1, item 7
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,630$1,630Sep 22, 2017Final
Citation 1, item 8
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$1,630$1,630Sep 22, 2017Final
Citation 1, item 9
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$1,630$1,630Sep 22, 2017Final
Citation 2, item 1
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$0$0Sep 22, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(5)

(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.

29 CFR 1910.107(d)(5)

(5) Electric motors. Electric motors driving exhaust fans shall not be placed inside booths or ducts. See also paragraph (c) of this section.

29 CFR 1910.107(e)(2)

(2) Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

Other truck trailer manufacturing employers in Mississippi

Alert subscribers get notified of each newly cited employer in Mississippi the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.