OSHA SearchOSHA records by employer

Beach Sign and Design LLC: OSHA inspections and violations

Virginia Beach, Virginia · Sign Manufacturing · NAICS 339950

3inspections
27citation items
$6,153current penalties
Oct 3, 2025last inspection

Since 2025, OSHA inspectors have visited Beach Sign and Design LLC in Virginia 3 times.

The most recent inspection opened on Oct 3, 2025 after a complaint, in Chesapeake.

In all, OSHA issued 27 citation items: 20 serious and 7 other-than-serious.

The proposed penalties came to $8,790; today they stand at $6,153, 30% less.

The rule cited most here is 1910.134 (respiratory protection), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Beach Sign and Design LLC averages $2,051 across 3 cited inspections.

Beach Sign and Design LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

249employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Beach Sign and Design LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348539461 OPENED OCT 3, 2025Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Apr 28, 2026

1322 Greenbrier Pkwy, Chesapeake, VA 23320 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$690$483Mar 16, 2026Final
Citation 2, item 1
29 CFR 1926.50(c) · Medical services and first aid
Other-than-serious$0$0Mar 16, 2026Final

Inspection 348376120 OPENED JUL 16, 2025Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Mar 23, 2026

332 Cleveland Place, Virginia Beach, VA 23462 · Sign Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 16VAC25-60-120
Serious$2,010$1,407Dec 23, 2025Final
Citation 1, item 1b
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$0$0Dec 23, 2025Final
Citation 1, item 1c
29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks
Serious$0$0Dec 23, 2025Final
Citation 1, item 1d
29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks
Serious$0$0Dec 23, 2025Final
Citation 1, item 1e
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$0$0Dec 23, 2025Final
Citation 1, item 2a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$2,010$1,407Dec 23, 2025Final
Citation 1, item 2b
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Dec 23, 2025Final
Citation 1, item 2c
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$0$0Dec 23, 2025Final
Citation 2, item 1a
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Dec 23, 2025Final
Citation 2, item 1b
29 CFR 1910.37(b)(5) · Exit routes
Other-than-serious$0$0Dec 23, 2025Final
Citation 2, item 2a
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Dec 23, 2025Final
Citation 2, item 2b
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Dec 23, 2025Final

Inspection 348377417 OPENED JUL 16, 2025Closed

Complaint · Partial · Health · 4 employees at the site · Closed Jul 14, 2026

332 Cleveland Place, Virginia Beach, VA 23462 · Sign Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(1) · Spray painting and finishing
Serious$1,020$714Jan 9, 2026Final
Citation 1, item 1b
29 CFR 1910.107(b)(2) · Spray painting and finishing
Serious$0$0Jan 9, 2026Final
Citation 1, item 1c
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Jan 9, 2026Final
Citation 1, item 1d
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$0$0Jan 9, 2026Final
Citation 1, item 1e
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0Jan 9, 2026Final
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,020$714Jan 9, 2026Final
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Jan 9, 2026Final
Citation 1, item 2c
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Jan 9, 2026Final
Citation 1, item 2d
29 CFR 1910.134(k)(3) · Respiratory protection
Serious$0$0Jan 9, 2026Final
Citation 1, item 3
29 CFR 1910.212(a)(5) · Machine guarding
Serious$1,020$714Jan 9, 2026Final
Citation 1, item 4
29 CFR 16VAC25-60-120
Serious$1,020$714Jan 9, 2026Final
Citation 2, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jan 9, 2026Final
Citation 2, item 1b
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Jan 9, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(1)

(b) Spray booths—(1) Construction. Spray booths shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.37 · Exit routes

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

Other sign manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.