OSHA SearchOSHA records by employer

Bennington Potters, Inc.: OSHA inspections and violations

Bennington, Vermont · Pottery, Ceramics, and Plumbing Fixture Manufacturing · NAICS 327112

12inspections
48citation items
$7,335current penalties
Jan 16, 2019last inspection

Bennington Potters, Inc. has 12 OSHA inspections on record in Vermont, the first in 1972.

OSHA's last visit started on Jan 16, 2019 as a planned inspection, in Bennington.

Across those inspections OSHA issued 48 citation items: 24 serious and 24 other-than-serious.

OSHA proposed $10,434 in penalties. After settlements and reviews the total is $7,335, down 30%.

Most often, OSHA cited 1910.305, electrical wiring methods (9 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Bennington Potters, Inc. averages $1,330 over 2 cited inspections in that time.

Bennington Potters, Inc.: OSHA citation items per year, 1972 to 2019
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

25employers cited

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch Bennington Potters, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343719407 OPENED JAN 16, 2019Closed

Planned · Complete · Health · 13 employees at the site · Closed Aug 9, 2019

324 County St, Bennington, VT 05201 · Pottery, Ceramics, and Plumbing Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$2,217$1,330Jul 3, 2019Final
Citation 1, item 2
29 CFR 1910.1053(d)(1) · Silica dust in general industry
Serious$2,217$1,330Jul 3, 2019Final
Citation 2, item 1
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Jul 3, 2019Final
Citation 2, item 2
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Other-than-serious$0$0Jul 3, 2019Final
Citation 2, item 3
29 CFR 1910.1053(f)(2)(i) · Silica dust in general industry
Other-than-serious$0$0Jul 3, 2019Final

Inspection 342859071 OPENED JAN 3, 2018Closed

Complaint · Partial · Safety · 31 employees at the site · Closed Mar 7, 2018

324 County St, Bennington, VT 05201 · Pottery, Ceramics, and Plumbing Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Mar 1, 2018Final

Inspection 311480032 OPENED FEB 27, 2009Closed

Referral · Partial · Safety · 18 employees at the site · Closed Apr 27, 2009

324 County Street, Bennington, VT 05201 · Pottery, Ceramics, and Plumbing Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$600$400Mar 18, 2009Closed

Inspection 311478820 OPENED JAN 26, 2009Closed

Planned · Complete · Health · 25 employees at the site · Closed Mar 30, 2009

324 County Street, Bennington, VT 05201 · Pottery, Ceramics, and Plumbing Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$225$225Feb 26, 2009Closed

Inspection 305530982 OPENED DEC 9, 2002Closed

Planned · Complete · Safety · 51 employees at the site · Closed Jul 28, 2003

324 County Street, Bennington, VT 05201 · Pottery, Ceramics, and Plumbing Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$700$700Jan 8, 2003Closed
Citation 1, item 2
29 CFR 1910.23(b)(1)(i) · Guarding floor and wall openings and holes
Serious$875$875Jan 8, 2003Closed
Citation 2, item 1
29 CFR 1910.146(c)(4) · Permit-required confined spaces
Other-than-serious$0$0Jan 8, 2003Closed

Inspection 301490561 OPENED JAN 21, 1998Closed

Planned · Complete · Safety · 25 employees at the site · Closed Jan 5, 2011

324 County Street, Bennington, VT 05201 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(6) · Spray painting and finishing
Serious$100$50Jan 30, 1998Closed
Citation 1, item 1b
29 CFR 1910.107(c)(2) · Spray painting and finishing
Serious$0$0Jan 30, 1998Closed
Citation 1, item 2a
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$100$50Jan 30, 1998Closed
Citation 1, item 2b
29 CFR 1910.305(g)(1)(i) · Electrical wiring methods
Serious$0$0Jan 30, 1998Closed
Citation 1, item 2c
29 CFR 1910.305(j)(2)(ii) · Electrical wiring methods
Serious$0$0Jan 30, 1998Closed
Citation 2, item 1
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jan 30, 1998Closed
Citation 2, item 2
29 CFR 1910.253(e)(3)(ii) · Gas welding and cutting
Other-than-serious$0$0Jan 30, 1998Closed

Inspection 124427931 OPENED APR 26, 1995Closed

Complaint · Partial · Health · 40 employees at the site · Closed Jan 5, 2011

324 County Street, Bennington, VT 05201 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(b)(1) · Respiratory protection
Serious$700$350Sep 15, 1995Closed
Citation 1, item 1b
29 CFR 1910.1000(a)(3) · Air contaminants
Serious$0$0Sep 15, 1995Closed
Citation 1, item 1c
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Sep 15, 1995Closed

Inspection 124424185 OPENED JAN 3, 1995Closed

Planned · Complete · Safety · 50 employees at the site · Closed Jan 5, 2011

324 County Street, Bennington, VT 05201 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Serious$375$375Jan 19, 1995Closed
Citation 1, item 2
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Serious$375$375Jan 19, 1995Closed
Citation 1, item 3a
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$375$375Jan 19, 1995Closed
Citation 1, item 3b
29 CFR 1910.305(g)(1)(i) · Electrical wiring methods
Serious$0$0Jan 19, 1995Closed
Citation 2, item 1a
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Jan 19, 1995Closed
Citation 2, item 1b
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Jan 19, 1995Closed
4 older inspections

Inspection 111723631 OPENED NOV 12, 1991Closed

Planned · Complete · Safety · 50 employees at the site · Closed Apr 6, 1992

324 County Street, Bennington, VT 05201 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$525$300Jan 6, 1992Closed
Citation 1, item 2a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$525$300Jan 6, 1992Closed
Citation 1, item 2b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 6, 1992Closed
Citation 1, item 3a
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Serious$525$300Jan 6, 1992Closed
Citation 1, item 3b
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Jan 6, 1992Closed
Citation 1, item 3c
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$0$0Jan 6, 1992Closed
Citation 2, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Jan 6, 1992Closed
Citation 2, item 2
29 CFR 1910.37(f)(2) · Exit routes
Other-than-serious$0$0Jan 6, 1992Closed
Citation 2, item 3
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jan 6, 1992Closed
Citation 2, item 4
29 CFR 1910.213(b)(3) · Woodworking machinery
Other-than-serious$0$0Jan 6, 1992Closed

Inspection 18673798 OPENED NOV 6, 1986Closed

Planned · Complete · Safety · 60 employees at the site · Closed Dec 24, 1986

324 County Street, Bennington, VT 05201 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(b)(6) · Exit route design
Other-than-serious$0$0Nov 21, 1986Closed
Citation 1, item 2
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Nov 21, 1986Closed
Citation 1, item 3
29 CFR 1910.213(h)(1) · Woodworking machinery
Other-than-serious$0$0Nov 21, 1986Closed
Citation 1, item 4
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0Nov 21, 1986Closed
Citation 1, item 5
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Nov 21, 1986Closed
Citation 1, item 6
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Nov 21, 1986Closed
Citation 1, item 7
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0Nov 21, 1986Closed
Citation 1, item 8
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Nov 21, 1986Closed
Citation 1, item 9
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Nov 21, 1986Closed
Citation 1, item 10
29 CFR 1910.305(g)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Nov 21, 1986Closed

Inspection 10353977 OPENED APR 12, 1973Closed

Complaint · Complete · Health · 35 employees at the site · Closed Mar 10, 1984

324 County St, Bennington, VT 05201 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 10353563 OPENED AUG 24, 1972Closed

Planned · Partial · Health · 50 employees at the site · Closed Mar 10, 1984

324 County St, Bennington, VT 05201 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.141(g)(1) · Sanitation
Other-than-serious$0$0Sep 28, 1972Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.1053 · Silica dust in general industry

29 CFR 1910.1053(d)(1)

(d) Exposure assessment—(1) General. The employer shall assess the exposure of each employee who is or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2) or the scheduled monitoring option in paragraph (d)(3) of this section.

29 CFR 1910.1053(f)(2)(i)

(2) Written exposure control plan. (i) The employer shall establish and implement a written exposure control plan that contains at least the following elements:

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

Other pottery, ceramics, and plumbing fixture manufacturing employers in Vermont

Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.