Since 1990, OSHA inspectors have visited Biewer-Wisconsin Sawmill, Inc. in Wisconsin 16 times.
The most recent inspection opened on Jun 24, 2025 on a referral, in Prentice.
In all, OSHA issued 78 citation items: 55 serious, 10 repeat and 13 other-than-serious.
The proposed penalties came to $175,268; today they stand at $133,695, 24% less.
The rule cited most here is 1910.147 (lockout/tagout), 26 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Biewer-Wisconsin Sawmill, Inc. averages $20,685 across 5 cited inspections.
Biewer-Wisconsin Sawmill, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 6 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Wisconsin · latest 90 days of OSHA records
214employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Biewer-Wisconsin Sawmill, Inc. and get notified the morning OSHA posts a new citation for it.
Incident on Sep 5, 2018: Employee catches hand between motor belt and pulley, fractur
At 9:15 a.m. on September 5, 2018, an employee was reinstalling a drive motor belt for the number 2 pressure roller on an edger that had fallen off of its drive sprockets. The employee was rolling the drive motor belt onto the drive sprocket when the pulley unexpectedly moved and pulled his hand in between the belt and sprocket. The employee sustained a fractured thumb, lacerated his palm and the back of his hand, and abrasions on his index, middle finger, and ring finger. The employee was hospitalized.
Incident on Sep 13, 2018: Employee amputates hand when struck by spline remover head
At 11:00 p.m. on September 13, 2018, an employee was clearing a blocked photo eye on the spline remover and entered the guardrail while the remover was running and other equipment was not isolated or locked out. The employee's right hand came into contact with the remover head and was amputated at the wrist. The employee was hospitalized.
Incident on May 25, 2017: Employee sustains fractures and partial amputation of finger
At 6:30 a.m. on May 25, 2017, an edger operator in-training was adjusting the position of a board on in-feed side of an edger's conveyor chain. The employee's fingertip was caught between the feed stock material and a pressure in-feed roller. The employee reached into the clamping/in-feed roller area of the edger without using the companies alternative safety procedure for adjusting the position of a skewed boards on the in-feed side of the edger and did not lockout the edger and related in-feed conveyor equipment. The employee sustained fractures and partial amputation of right ring finger to the first knuckle. the first knuckle.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Prentice site logged 4 recordable injuries or illnesses among about 110 workers: 3.3 per 100 full-time workers, against a median of 4.2 for its industry. Those cases cost 145 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Biewer Wisconsin Sawmill, Inc.
Prentice · 2025
110
4
2
3.3
4.2
Included with any plan: 8 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 6 reports on file.
Jun 18, 2025, Prentice: Hospitalization · multiple severe wounds and internal injuries · multiple trunk locations
A maintenance employee was dismantling a kiln. As he was pulling top panels apart, a panel gave out and he fell approximately 6-8 feet, resulting in a fractured lower vertebra and a bruised lung. Fall protection was not tied off at the time.
May 6, 2021, Prentice: Amputation · amputations · fingertip(s)
On May 6, 2021, an employee was unjamming a machine. As a sorter bin was lowering, the employee's left index finger was pulled into the pulley system resulting in a fingertip amputation.
On September 13, 2018, at approximately 11:00 p.m., an employee operating a CNS computer identified a blocked photo eye and used water to clean the photo eye. The employee then saw wood in the machine and was attempting to remove it when the employee contacted the spline remover, resulting in an amputation of the right hand.
An employee was changing a belt on a machine when the belt lacerated the employee's right hand, causing tendon damage that required surgery. The machine was not locked out at the time of the incident.
An employee was trying to remove a board that was lodged in the infeed of an edger when his right ring finger made contact with the cutter-head and was amputated.
A PSI blower chip loading system plugged up and tripped the breaker. A maintenance employee locked out the machine, cleared the plug, and restarted the machine. The employee was checking for air flow through the pipes with his right index finger hanging at the stop plate when the mechanical sleeve lacerated the finger pad. The machine amputated a chunk of the right index finger pad. The…
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.