OSHA SearchOSHA records by employer

Big Lake Services: OSHA inspections and violations

Rankin, Texas · Support Activities for Oil and Gas Operations · NAICS 213112

5inspections
6citation items
$30,241current penalties
Aug 31, 2017last inspection

OSHA has inspected Big Lake Services 5 times in Texas since 2010.

The latest one began on Aug 31, 2017 after a fatality or catastrophe, in Midland.

Those inspections ended with 6 citation items: 6 serious.

Penalties were first proposed at $49,102 and now stand at $30,241, 38% lower after settlements or reviews.

the General Duty Clause comes up most often in these citations: 3 items under Section 5(a)(1).

How that compares: the median penalty per cited inspection for mining and oil and gas employers since 2015 is $2,880, and Big Lake Services averages $8,774 (3 cited inspections).

1 inspection on this page followed a fatal incident.

It reported 3 severe injuries to OSHA since 2015.

Big Lake Services: OSHA citation items per year, 2010 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Big Lake Services again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342608163 OPENED AUG 31, 2017Closed

Fatality or catastrophe · Partial · Safety · 5 employees at the site · Closed Apr 16, 2019

Well Number 3305h, Midland, TX 79701 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps

Incident on Aug 31, 2017 (fatal): Employee is struck by falling block and is killed

At 7:00 a.m. on August 31, 2017, an employee was cutting bands from a pipe that was being removed. The employee was struck by a traveling block when the tubing lines snapped and the block dropped, killing the employee.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$12,805$8,239Jan 11, 2018Final

Inspection 342019841 OPENED JAN 9, 2017Closed

Referral · Partial · Safety · 4 employees at the site · Closed Aug 21, 2017

Dorothy A-02 Wb Upton County, Crane, TX 79731 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps

Incident on Jan 6, 2017: Employee is struck by pressurized valve and is injured

At 11:00 a.m. on January 6, 2017, during cold weather temperatures, an employee and a coworker were removing frozen bolts on a pressurized BOP. During work, the employee was struck by a pressurized valve that became airborne during its removal. The employee sustained a head injury and fractured leg. fractured leg.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(b) · Machine guarding
Serious$7,171$4,303Jun 13, 2017Final
Citation 1, item 2
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$10,755$6,453Jun 13, 2017Final
Citation 1, item 3
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$7,171$4,303Jun 13, 2017Final

Inspection 340808617 OPENED JUL 28, 2015Closed

Fatality or catastrophe · Partial · Safety · 150 employees at the site · Closed Oct 29, 2015

Cr 105 Lynch 16 Lease #1, Rankin, TX 79778 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$6,300$3,024Oct 6, 2015Final

Inspection 340494509 OPENED MAR 25, 2015Closed

Planned · Complete · Safety · 4 employees at the site · Closed Sep 24, 2015

Fdl Energy Gardendale 6-5, Gardendale, TX 79758 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314703893 OPENED DEC 2, 2010Closed

Accident · Complete · Safety · 4 employees at the site · Closed Apr 16, 2012

2.5 Mi West Of Hwy 349 On Cty Rd 107, Rankin, TX 79778 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps

Incident on Dec 2, 2010: Employee's burned in flash explosion

On December 2, 2010, Employee #1 and three coworkers were removing tubing from a well when a release of toxic hydrocarbons to the atmosphere occurred. The hydro carbons ignited, engulfing the work over the rig in flames. Employee #1 suffered 3rd degree burns over 77% of his body. Employee #2 suffered 2nd degree burns to the face. Employee #3 suffered 2nd degree burns to the abdomen. Employee #4 suf fered 1st degree burns to the face. The Four Employees were hospitalized for the ir injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$4,900$3,920May 31, 2011Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 3 reports on file.

Jan 6, 2017, Crane: Hospitalization · traumatic injuries and disorders, unspecified · nonclassifiable

An employee was working on a blowout preventer. When he went to remove the valve removal plug, pressure (approximately 300 PSI) released and struck him, blowing him 20 to 30 feet away. He was hospitalized.

May 4, 2016, Rankin: Hospitalization · soreness, pain, hurt-nonspecified injury · forearm(s)

An employee was standing next to the tubing waiting for the hydrotester to go down the hole and plug in the water hose when the hydrotester broke sticking the employee on the right forearm.

Jul 27, 2015, Rankin: Hospitalization, amputation · amputations · finger(s), fingernail(s), n.e.c.

An employee's third and fourth digits were amputated.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(b)

(b) Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving.

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.243(c)(3)

(3) Vertical portable grinders. Safety guards used on machines known as right angle head or vertical portable grinders shall have a maximum exposure angle of 180°, and the guard shall be so located so as to be between the operator and the wheel during use. Adjustment of guard shall be such that pieces of an accidentally broken wheel will be deflected away from the operator. (See Figure P-4.)

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(2)(iv)

(iv) Valve protection caps, where cylinder is designed to accept a cap, shall always be in place, hand-tight, except when cylinders are in use or connected for use.

OSH Act Section 5 · General Duty Clause

Other support activities for oil and gas operations employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.